Estimation of plasma insulin from plasma glucose

被引:25
作者
Neatpisarnvanit, C
Boston, JR
机构
[1] Mahidol Univ, Dept Elect Engn, Nakhon Prathom 73170, Thailand
[2] Univ Pittsburgh, Dept Elect Engn, Pittsburgh, PA 15260 USA
关键词
glucose-insulin metabolism; insulin estimation; intravenous glucose tolerance test; minimal model;
D O I
10.1109/TBME.2002.804599
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Two plasma insulin estimators are derived and evaluated in this paper. The estimators use continuously monitored plasma glucose, and they are based on a simple mathematical model of glucose-insulin metabolism. The first estimator (Estimator 1) was obtained from the glucose subsystem of the simplified model, which includes plasma glucose and interstitial insulin compartments. The second estimator (Estimator 2) was developed from the insulin kinetics subsystem of the simplified model. The performances of the estimators were compared using computer simulations and data from clinical intravenous glucose tolerance test procedures and from animal experiments.
引用
收藏
页码:1253 / 1259
页数:7
相关论文
共 21 条
[1]   EFFECT OF HEPARIN ON INSULIN-GLUCOSE INTERACTIONS MEASURED BY THE MINIMAL MODEL TECHNIQUE - IMPLICATIONS FOR REPRODUCTIBILITY USING THIS METHOD [J].
ABBATE, SL ;
FUJIMOTO, WY ;
BRUNZELL, JD ;
KAHN, SE .
METABOLISM-CLINICAL AND EXPERIMENTAL, 1993, 42 (03) :353-357
[2]   CLINICAL CONTROL OF DIABETES BY ARTIFICIAL PANCREAS [J].
ALBISSER, AM ;
LEIBEL, BS ;
EWART, TG ;
DAVIDOVAC, Z ;
BOTZ, CK ;
ZINGG, W ;
SCHIPPER, H ;
GANDER, R .
DIABETES, 1974, 23 (05) :397-404
[3]  
Bergman R. N., 1980, P 5 IFAC S ID SYST P, V2, P883
[4]   TOWARD PHYSIOLOGICAL UNDERSTANDING OF GLUCOSE-TOLERANCE - MINIMAL-MODEL APPROACH [J].
BERGMAN, RN .
DIABETES, 1989, 38 (12) :1512-1527
[5]   PHYSIOLOGIC EVALUATION OF FACTORS CONTROLLING GLUCOSE-TOLERANCE IN MAN - MEASUREMENT OF INSULIN SENSITIVITY AND BETA-CELL GLUCOSE SENSITIVITY FROM THE RESPONSE TO INTRAVENOUS GLUCOSE [J].
BERGMAN, RN ;
PHILLIPS, LS ;
COBELLI, C .
JOURNAL OF CLINICAL INVESTIGATION, 1981, 68 (06) :1456-1467
[6]   AN ADAPTIVE PLASMA-GLUCOSE CONTROLLER BASED ON A NONLINEAR INSULIN/GLUCOSE MODEL [J].
CANDAS, B ;
RADZIUK, J .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (02) :116-124
[7]  
*CIV SOFTW INC, 1999, MLAB CURV FITT FEAT
[8]   OPTIMAL INSULIN INFUSION RESULTING FROM A MATHEMATICAL-MODEL OF BLOOD-GLUCOSE DYNAMICS [J].
FISHER, ME ;
TEO, KL .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (04) :479-486
[9]   BLOOD-GLUCOSE CONTROL BY INTERMITTENT LOOP CLOSURE IN THE BASAL MODE - COMPUTER-SIMULATION STUDIES WITH A DIABETIC MODEL [J].
FURLER, SM ;
KRAEGEN, EW ;
SMALLWOOD, RH ;
CHISHOLM, DJ .
DIABETES CARE, 1985, 8 (06) :553-561
[10]  
GANDER W, 1995, SOLVING PROBLEMS SCI, pCH9