Audit of neurophysiological recording during movement disorder surgery

被引:10
作者
Forster, A
Eljamel, MS
Varma, TRK
Tulley, M
Latimer, M
机构
[1] Ninewells Hosp, Dept Neurophysiol, Dundee DD1 9SY, Scotland
[2] Ninewells Hosp, Dept Neurol Surg, Dundee DD1 9SY, Scotland
[3] Ninewells Hosp, Dept Med Phys, Dundee DD1 9SY, Scotland
[4] Walton Ctr Neurol & Neurosurg, Liverpool, Merseyside, England
[5] Univ St Andrews, Dept Psychol, St Andrews KY16 9AJ, Fife, Scotland
关键词
movement disorder surgery; microelectrode recording;
D O I
10.1159/000029719
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Sixty-two cases of thalamic pallidal and subthalamic surgery in Dundee were audited to assess the influence of physiological localisation on the procedure. Methods included microelectrode recording, evoked potential and stimulation techniques. Although anatomical localisation is improving with modern techniques, the physiological information is still modifying the surgery in 67% of cases. Copyright (C) 2000 S. Karger AG, Basel.
引用
收藏
页码:154 / 156
页数:3
相关论文
共 2 条
[1]  
ELJAMEL MS, 1999, M AM SOC STER FUNCT
[2]  
Tasked, 1987, NEUROSURGERY STATE A, P193