New parameters in assessment of human donor corneal stroma

被引:14
作者
Borderie, Marie [1 ,2 ]
Grieve, Kate [1 ,2 ]
Irsch, Kristina [1 ,2 ,3 ]
Ghoubay, Djida [1 ,2 ]
Georgeon, Cristina [1 ,2 ]
De Sousa, Celine [4 ]
Laroche, Laurent [1 ,2 ]
Borderie, Vincent M. [1 ,2 ]
机构
[1] Paris VI Univ, Quinze Vingts Natl Ophthalmol Hosp, Paris, France
[2] UPMC Univ Paris 06, Vis Inst, CIC 1423, INSERM,U968,CNRS,UMR S 968,CHNO,UMR 7210, F-UMR7210 Paris, France
[3] Johns Hopkins Univ, Sch Med, Wilmer Eye Inst, Lab Ophthalm Instrument Dev, Baltimore, MD 21205 USA
[4] French Blood Estab, Tissue Bank, Paris, Ile De France, France
基金
欧洲研究理事会;
关键词
cornea; donor tissue; keratocyte; optical coherence tomography; stroma; OPTICAL COHERENCE TOMOGRAPHY; DEEP LAMELLAR KERATOPLASTY; IN-VIVO; PENETRATING KERATOPLASTY; CONFOCAL MICROSCOPY; KERATOCYTE DENSITY; ANTERIOR LAMELLAR; ULTRAHIGH-RESOLUTION; TISSUE SELECTION; ORGAN-CULTURE;
D O I
10.1111/aos.13351
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo provide quantitative parameters for assessment of human donor corneal stroma by imaging stromal features of diseased and normal human corneas with full-field optical coherence microscopy (FFOCM), using confocal microscopy (CM) and histology as reference techniques. MethodsBowman's layer (BL) thickness and keratocyte density were assessed exvivo in 23 human donor corneas and 27 human pathological corneas (keratoconus and other corneal disorders) with FFOCM, CM and histology. Stromal backscattering was assessed with FFOCM. Additionally, 10 normal human corneas were assessed invivo with CM. ResultsIn FFOCM, the logarithm of the normalized stromal reflectivity was a linear function of stromal depth (R-2=0.95) in human donor corneas. Compared with keratoconus corneas, human donor corneas featured higher BL thickness (p=0.0014) with lower coefficient of variation (BL-COV; p=0.0002), and linear logarithmic stromal reflectivity with depth (higher R-2, p=0.0001). Compared with other corneal disorders, human donor corneas featured lower BL-COV (p=0.012) and higher R-2 (p=0.0001). Using the 95% confidence limits of the human donor cornea group, BL thickness<6.5m (sensitivity, 57%; specificity, 100%), BL-COV>18.6% (79%; 100%) and R-2<0.94 (93%; 71%) were revealed as indictors of abnormal cornea. In CM, keratocyte density decreased with stromal depth (r=-0.56). The mean overall keratocyte density (cells/mm(2)) was 205 in human donor corneas, 244 in keratoconus, 176 in other corneal disorders and 386 in normal corneas. ConclusionFull-field optical coherence microscopy (FFOCM) provides precise and reliable parameters for non-invasive assessment of human donor corneal stroma during storage, enabling detection of stromal disorders that could impair the results of keratoplasty.
引用
收藏
页码:E297 / E306
页数:10
相关论文
共 40 条
[1]   Ultrahigh-resolution imaging of human donor cornea using full-field optical coherence tomography [J].
Akiba, Masahiro ;
Maeda, Naoyuki ;
Yumikake, Kazuhiko ;
Soma, Takeshi ;
Nishida, Kohji ;
Tano, Yasuo ;
Chan, Kin Pui .
JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (04)
[2]   Fluid lamellar keratoplasty in keratoconus [J].
Amayem, AF ;
Anwar, M .
OPHTHALMOLOGY, 2000, 107 (01) :76-79
[3]  
Bahar I, 2011, AM J OPHTHALMOL, V151, P760
[4]   Comparison of Three Different Techniques of Corneal Transplantation for Keratoconus [J].
Bahar, Irit ;
Kaiserman, Igor ;
Srinivasan, Sathish ;
Ya-Ping, Jin ;
Slomovic, Allan R. ;
Rootman, David S. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 146 (06) :905-912
[5]   Use of Fourier-Domain Optical Coherence Tomography to Evaluate Anterior Stromal Opacities in Donor Corneas [J].
Bald, Matthew R. ;
Stoeger, Christopher ;
Galloway, Joshua ;
Tang, Maolong ;
Holiman, Jeffrey ;
Huang, David .
JOURNAL OF OPHTHALMOLOGY, 2013, 2013
[6]   Full-field optical coherence microscopy [J].
Beaurepaire, E ;
Boccara, AC ;
Lebec, M ;
Blanchot, L ;
Saint-Jalmes, H .
OPTICS LETTERS, 1998, 23 (04) :244-246
[7]   Evaluation of Contact Lens-Induced Changes in Keratoconic Corneas Using In Vivo Confocal Microscopy [J].
Bitirgen, Gulfidan ;
Ozkagnici, Ahmet ;
Malik, Rayaz A. ;
Oltulu, Refik .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (08) :5385-5391
[8]   Light microscopic evaluation of human donor corneal stroma during organ culture [J].
Borderie, V ;
Martinache, C ;
Sabolic, V ;
Touzeau, O ;
Laroche, L .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 1998, 76 (02) :154-157
[9]   Donor Tissue Selection for Anterior Lamellar Keratoplasty [J].
Borderie, Vincent M. ;
Sandali, Otman ;
Basli, Elena ;
Goldschmidt, Pablo ;
Laroche, Laurent .
CORNEA, 2013, 32 (08) :1105-1109
[10]   Long-term Results of Deep Anterior Lamellar versus Penetrating Keratoplasty [J].
Borderie, Vincent M. ;
Sandali, Otman ;
Bullet, Julien ;
Gaujoux, Thomas ;
Touzeau, Olivier ;
Laroche, Laurent .
OPHTHALMOLOGY, 2012, 119 (02) :249-255