Influence of Annular Beam Displacement on the Performance of a High-Power Gyrotron

被引:10
作者
Samartsev, Andrey [1 ]
Dammertz, Gunter [1 ]
Gantenbein, Gerd [1 ]
Jelonnek, John [1 ]
Illy, Stefan [1 ]
Thumm, Manfred [1 ]
机构
[1] Karlsruhe Inst Technol, Inst Pulsed Power & Microwave Technol, EURATOM Assoc, D-76131 Karlsruhe, Germany
关键词
Gyrotron; millimeter waves; misalignment of electron beam; ELECTRON-BEAM; CAVITY; MISALIGNMENT; PARAMETERS;
D O I
10.1109/TPS.2013.2248385
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
In this paper, we present the results of an experimental study on the influence of the lateral misalignment between the axes of the annular electron beam and the cavity on the performance of a 1-MW 140-GHz gyrotron. The subject of the study is of practical interest. On one hand, the discrepancy between numerical simulations of the gyrotron performance and experimental results could by partially attributed to the beam misalignment. On the other, it is in practice very difficult to reach the necessary tolerances in series production of high-power high-frequency (>100 GHz) gyrotrons. The problem actually will become more demanding with the increase of the operating frequency of the working mode because the required accuracy scales with the wavelength of the electromagnetic wave. It is shown that a large displacement of the annular beam from the cavity axis may lead to the excitation of a competing mod which is not excited under normal conditions. The excitation of the main mode is observed, however, at a beam-cavity displacement of up to 0.8 mm.
引用
收藏
页码:872 / 878
页数:7
相关论文
共 13 条
[1]   Nonstationary oscillations in gyrotrons [J].
Airila, MI ;
Dumbrajs, O ;
Reinfelds, A ;
Strautins, U .
PHYSICS OF PLASMAS, 2001, 8 (10) :4608-4612
[2]   Effect of resonator parameters on frequency and quality factor of gyrotron resonators [J].
Borie, Edith .
INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 2008, 29 (02) :113-130
[3]   The electron cyclotron maser [J].
Chu, KR .
REVIEWS OF MODERN PHYSICS, 2004, 76 (02) :489-540
[4]   Recent results of the 1-MW, 140-GHz, TE22,6-mode gyrotron [J].
Dammertz, G ;
Braz, O ;
Chopra, AK ;
Koppenburg, K ;
Kuntze, M ;
Piosczyk, B ;
Thumm, M .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 1999, 27 (02) :330-339
[5]  
Dammertz G., 1990, P SOC PHOTO-OPT INS, V1514, P502
[6]   KINETIC-THEORY OF ELECTRON-CYCLOTRON RESONANCE MASERS WITH ASYMMETRY OF THE ELECTRON-BEAM IN A CAVITY [J].
DUMBRAJS, O ;
LIU, SG .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 1992, 20 (03) :126-132
[7]   Experimental Investigations and Analysis of Parasitic RF Oscillations in High-Power Gyrotrons [J].
Gantenbein, Gerd ;
Dammertz, Guenter ;
Flamm, Jens ;
Illy, Stefan ;
Kern, Stefan ;
Latsas, George ;
Piosczyk, Bernhard ;
Rzesnicki, Tomasz ;
Samartsev, Andrey ;
Schlaich, Andreas ;
Thumm, Manfred ;
Tigelis, Ioannis .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 2010, 38 (06) :1168-1177
[8]  
Ginzburg N. S., 1986, Radiophysics and Quantum Electronics, V29, P89, DOI 10.1007/BF01034008
[9]  
Illy S., 2008, P 7 SCH PHYS PLASM F, P1
[10]  
Petelin MI, 1975, Radiophys Quantum Electron, V18, P212, DOI [10.1007/BF01036881, DOI 10.1007/BF01036881]