Protective mechanisms of end-ischemic cold machine perfusion in DCD liver grafts

被引:212
作者
Schlegel, Andrea [1 ]
de Rougemont, Olivier [1 ]
Graf, Rolf [1 ]
Clavien, Pierre-Alain [1 ]
Dutkowski, Philipp [1 ]
机构
[1] Univ Zurich Hosp, Dept Surg, Swiss HPB & Transplant Ctr, CH-8091 Zurich, Switzerland
基金
瑞士国家科学基金会;
关键词
Hypothermic machine perfusion; DCD liver; Oxygen; Perfusion pressure; Mitochondrial injury; Endothelial injury; HEPATIC ISCHEMIA/REPERFUSION INJURY; RAT-LIVER; GASEOUS OXYGEN; PORCINE LIVERS; PRESERVATION; TRANSPLANTATION; STORAGE; KIDNEYS; DONOR; CELLS;
D O I
10.1016/j.jhep.2012.10.004
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background & Aims: The aim of this study was to identify protective mechanisms of cold machine perfusion in liver grafts donated after cardiac death. Methods: Pig livers exposed to 60-min warm ischemia were cold stored for 7 h or treated after 6-h cold storage with 1-h hypothermic oxygenated perfusion (HOPE) through the portal vein. Different physical (perfusion pressure) and chemical (oxygen, mitochondrial transition pore inhibition) parameters were analyzed during machine perfusion to dissect key steps of mechanism. Results: HOPE treatment led to a significant slowdown of mitochondrial respiration rate during 1-h machine perfusion. After reperfusion following low pressure HOPE, mitochondrial injury, nuclear injury, Kupffer cell activation and endothelial injury were significantly improved, as tested on an isolated liver perfusion model. In contrast, machine perfusion with deoxygenated perfusate showed no protection from hepatocyte injury and Kupffer cell activation. However, endothelial injury was also prevented by low pressure machine perfusion in the absence of oxygen. Perfusion with higher pressure provoked endothelial damage and Kupffer cell activation. Conclusions: The mechanisms of protection by hypothermic machine perfusion appear to be at least twofold. First, oxygenation under hypothermic conditions protects from mitochondrial and nuclear injury by downregulation of mitochondrial activity before reperfusion. Second, cold perfusion itself, under low pressure conditions, prevents endothelial damage, independently of oxygen. (C) 2012 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:278 / 286
页数:9
相关论文
共 30 条
[1]   Is extracorporeal hypothermic machine perfusion of the liver better than the 'good old icebox'? [J].
Bae, Coney ;
Henry, Scot D. ;
Guarrera, James V. .
CURRENT OPINION IN ORGAN TRANSPLANTATION, 2012, 17 (02) :137-142
[2]   One Hour Hypothermic Oxygenated Perfusion (HOPE) Protects Nonviable Liver Allografts Donated After Cardiac Death [J].
de Rougemont, Olivier ;
Breitenstein, Stefan ;
Leskosek, Boris ;
Weber, Achim ;
Graf, Rolf ;
Clavien, Pierre-Alain ;
Dutkowski, Philipp .
ANNALS OF SURGERY, 2009, 250 (05) :674-683
[3]   From Vascular Corrosion Cast to Electrical Analog Model for the Study of Human Liver Hemodynamics and Perfusion [J].
Debbaut, Charlotte ;
Monbaliu, Diethard ;
Casteleyn, Christophe ;
Cornillie, Pieter ;
Van Loo, Denis ;
Masschaele, Bert ;
Pirenne, Jacques ;
Simoens, Paul ;
Van Hoorebeke, Luc ;
Segers, Patrick .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (01) :25-35
[4]   Machine perfusion for 'Marginal' liver grafts [J].
Dutkowski, P. ;
de Rougemont, O. ;
Clavien, P. -A. .
AMERICAN JOURNAL OF TRANSPLANTATION, 2008, 8 (05) :917-924
[5]   Novel short-term hypothermic oxygenated perfusion (HOPE) system prevents injury in rat liver graft from non-heart beating donor [J].
Dutkowski, Philipp ;
Furrer, Katarzyna ;
Tian, Yinghua ;
Graf, Rolf ;
Clavien, Pierre-Alain .
ANNALS OF SURGERY, 2006, 244 (06) :968-977
[6]   Rescue of the cold preserved rat liver by hypothermic oxygenated machine perfusion [J].
Dutkowski, R ;
Graf, R ;
Clavien, PA .
AMERICAN JOURNAL OF TRANSPLANTATION, 2006, 6 (05) :903-912
[7]   Hypothermic Oxygenated Machine Perfusion in Porcine Donation After Circulatory Determination of Death Liver Transplant [J].
Fondevila, Constantino ;
Hessheimer, Amelia J. ;
Maathuis, Mark-Hugo J. ;
Munoz, Javier ;
Taura, Pilar ;
Calatayud, David ;
Leuvenink, Henri ;
Rimola, Antoni ;
Garcia-Valdecasas, Juan C. ;
Ploeg, Rutger J. .
TRANSPLANTATION, 2012, 94 (01) :22-29
[8]   Hypothermic Reconditioning of Porcine Kidney Grafts by Short-Term Preimplantation Machine Perfusion [J].
Gallinat, Anja ;
Paul, Andreas ;
Efferz, Patrik ;
Lueer, Bastian ;
Kaiser, Gernot ;
Wohlschlaeger, Jeremias ;
Treckmann, Juergen ;
Minor, Thomas .
TRANSPLANTATION, 2012, 93 (08) :787-793
[9]   Hypothermic Machine Preservation in Human Liver Transplantation: The First Clinical Series [J].
Guarrera, J. V. ;
Henry, S. D. ;
Samstein, B. ;
Odeh-Ramadan, R. ;
Kinkhabwala, M. ;
Goldstein, M. J. ;
Ratner, L. E. ;
Renz, J. F. ;
Lee, H. T. ;
Brown, R. S., Jr. ;
Emond, J. C. .
AMERICAN JOURNAL OF TRANSPLANTATION, 2010, 10 (02) :372-381
[10]   Extracorporeal machine liver perfusion: are we warming up? [J].
Hessheimer, Amelia J. ;
Fondevila, Constantino ;
Garcia-Valdecasas, Juan C. .
CURRENT OPINION IN ORGAN TRANSPLANTATION, 2012, 17 (02) :143-147