Novel Reflectometry Method Based on Time Reversal for Cable Aging Characterization

被引:0
作者
El Sahmarany, Lola [1 ]
Auzanneau, Fabrice [1 ]
Bonnet, Pierre [2 ]
机构
[1] CEA, LIST, Embedded Syst Reliabil Lab, Nano Innov, Essonne, France
[2] Univ Blaise Pascal, Inst Pascal, Clermont Ferrand, France
来源
2012 IEEE 58TH HOLM CONFERENCE ON ELECTRICAL CONTACTS (HOLM) | 2012年
关键词
Aged cable; Transmission line; Reflectometry; Time Reversal; Skewness coefficient;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper investigates the effects of aging on electrical cable characteristics and proposes a new method for detecting and characterizing cable aging (i.e. homogeneous slow degradation) based on time reversal. In case of a global cable aging, the commonly used methods such as reflectometry provide non-relevant or inaccurate information. Through theoretical study and numerical simulations, the benefits of this new method called Time Reversal Reflectometry (TRR) are presented. TRR is experimentally shown to be successful for the detection and quantification of cable aging.