Biofuel cell-based self-powered biogenerators for online continuous monitoring of neurochemicals in rat brain

被引:46
作者
Cheng, Hanjun [1 ]
Yu, Ping [1 ]
Lu, Xulin [1 ]
Lin, Yuqing [1 ]
Ohsaka, Takeo [2 ]
Mao, Lanqun [1 ]
机构
[1] Chinese Acad Sci, Beijing Natl Lab Mol Sci, Key Lab Analyt Chem Living Biosyst, Inst Chem, Beijing 100190, Peoples R China
[2] Tokyo Inst Technol, Dept Elect Chem, Interdisciplinary Grad Sch Sci & Engn, Midori Ku, Yokohama, Kanagawa 2268502, Japan
关键词
CARBON-FIBER MICROELECTRODES; FOCAL CEREBRAL-ISCHEMIA; ELECTROCHEMICAL METHOD; TISSUE OXYGEN; FUEL-CELLS; GLUCOSE; SENSOR; INHIBITION; BIOSENSOR; ELECTRODE;
D O I
10.1039/c2an36385b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study demonstrates a new electrochemical method for continuous neurochemical sensing with a biofuel cell-based self-powered biogenerator as the detector for the analysis of microdialysate continuously sampled from rat brain, with glucose as an example analyte. To assemble a glucose/O-2 biofuel cell that can be used as a self-powered biogenerator for glucose sensing, glucose dehydrogenase (GDH) was used as the bioanodic catalyst for the oxidation of glucose with methylene green (MG) adsorbed onto single-walled carbon nanotubes (SWNTs) as the electrocatalyst for the oxidation of dihydronicotinamide adenine dinucleotide (NADH). Laccase crosslinked onto SWNTs was used as the biocathodic catalyst for the O-2 reduction. To enable the bioanode and biocathode to work efficiently in their individually favorable solutions and to eliminate the interference between the glucose bioanode and O-2 biocathode, the biofuel cell-based biogenerator was built in a co-laminar microfluidic chip so that the bioanodic and biocathodic streams could be independently optimized to provide conditions favorable for each of the bioelectrodes. By using a home-made portable voltmeter to output the voltage generated on an external resistor, the biogenerator was used for glucose sensing based on a galvanic cell mechanism. In vitro experiments demonstrate that, under the optimized conditions, the voltage generated on an external resistor shows a linear relationship with the logarithmic glucose concentration within a concentration range of 0.2 mM to 1.0 mM. Moreover, the biogenerator exhibits a high stability and a good selectivity for glucose sensing. The validity of the biofuel cell-based self-powered biogenerator for continuous neurochemical sensing was illustrated by online continuous monitoring of striatum glucose in rat brain through the combination of in vivo microdialysis. This study offers a new and technically simple platform for continuously monitoring physiologically important species in cerebral systems.
引用
收藏
页码:179 / 185
页数:7
相关论文
共 63 条
[21]   A miniature glucose/O2 biofuel cell with single-walled carbon nanotubes-modified carbon fiber microelectrodes as the substrate [J].
Li, Xianchan ;
Zhou, Haojie ;
Yu, Ping ;
Su, Lei ;
Ohsaka, Takeo ;
Mao, Lanqun .
ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (06) :851-854
[22]   A facille electrochemical method for simultaneous and on-line measurements of glucose and lactate in brain microdialysate with prussian blue as the electrocatalyst for reduction of hydrogen peroxide [J].
Lin, Yuqing ;
Liu, Kun ;
Yu, Ping ;
Xiang, Ling ;
Li, Xianchan ;
Mao, Lanqun .
ANALYTICAL CHEMISTRY, 2007, 79 (24) :9577-9583
[23]   Physiologically Relevant Online Electrochemical Method for Continuous and Simultaneous Monitoring of Striatum Glucose and Lactate Following Global Cerebral Ischemia/Reperfusion [J].
Lin, Yuqing ;
Zhu, Ningning ;
Yu, Ping ;
Su, Lei ;
Mao, Lanqun .
ANALYTICAL CHEMISTRY, 2009, 81 (06) :2067-2074
[24]   Dynamic regional changes of extracellular ascorbic acid during global cerebral ischemia: Studied with in vivo microdialysis coupled with on-line electrochemical detection [J].
Liu, Kun ;
Lin, Yuqing ;
Yu, Ping ;
Mao, Lanqun .
BRAIN RESEARCH, 2009, 1253 :161-168
[25]   Interstitial pO2 in ischemic penumbra and core are differentially affected following transient focal cerebral ischemia in rats [J].
Liu, SM ;
Shi, HL ;
Liu, WL ;
Furuichi, T ;
Timmins, GS ;
Liu, KJ .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2004, 24 (03) :343-349
[26]   Measurement of brain tissue oxygen at a carbon paste electrode can serve as an index of increases in regional cerebral blood flow [J].
Lowry, JP ;
Boutelle, MG ;
Fillenz, M .
JOURNAL OF NEUROSCIENCE METHODS, 1997, 71 (02) :177-182
[27]   Characteristics of a miniature compartment-less glucose-O2 biofuel cell and its operation in a living plant [J].
Mano, N ;
Mao, F ;
Heller, A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (21) :6588-6594
[28]   A miniature biofuel cell operating in a physiological buffer [J].
Mano, N ;
Mao, F ;
Heller, A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2002, 124 (44) :12962-12963
[29]   Parathion sensor based on molecularly imprinted sol-gel films [J].
Marx, S ;
Zaltsman, A ;
Turyan, I ;
Mandler, D .
ANALYTICAL CHEMISTRY, 2004, 76 (01) :120-126
[30]   Inhibition and Activation of Glucose Oxidase Bioanodes for Use in a Self-Powered EDTA Sensor [J].
Meredith, Matthew T. ;
Minteer, Shelley D. .
ANALYTICAL CHEMISTRY, 2011, 83 (13) :5436-5441