A label-free aptasensor for the sensitive and specific detection of cocaine using supramolecular aptamer fragments/target complex by electrochemical impedance spectroscopy

被引:38
|
作者
Zhang, De-Wen [1 ]
Zhang, Fang-Ting [1 ]
Cui, Yi-Ran [1 ]
Deng, Qin-Pei [1 ]
Krause, Steffi [2 ]
Zhou, Ying-Lin [1 ]
Zhang, Xin-Xiang [1 ]
机构
[1] Peking Univ, Coll Chem, Key Lab Biochem & Mol Engn, BNLMS, Beijing 100871, Peoples R China
[2] Univ London, Sch Engn & Mat Sci, London E1 4NS, England
基金
中国国家自然科学基金;
关键词
Aptamer fragment; Cocaine; Supramolecular complex; Label-free; Electrochemical impedance spectroscopy; SENSING PLATFORM; SMALL MOLECULES; IMPEDIMETRIC APTASENSOR; PROTEIN INTERACTIONS; STRAND DISPLACEMENT; GOLD NANOPARTICLES; SENSOR; BIOSENSOR; ADENOSINE; PROBE;
D O I
10.1016/j.talanta.2012.01.049
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and label-free aptasensor for sensitive and specific detection of cocaine was developed by measuring the change in electrochemical impedance spectra (EIS), based on the formation of a supramolecular aptamer fragments/substrate complex. An anticocaine aptamer was divided into two fragments, Cx and Cy. Three different sensing interfaces, called Au/Cx5S/MCE, Au/Cy3S/MCE and Au/Cy5S/MCE, were fabricated by immobilizing Cx or Cy on a gold electrode through modifying their 5' or 3' end with a thiolated group followed by the treatment with mercaptoethanol (MCE). The formation of the corresponding supramolecular aptamer fragments/cocaine complex was investigated via monitoring electrochemical impedance spectra in the presence of [Fe(CN)(6)](3-/4-). The interfacial electron transfer resistance (R-et) was found to depend strongly on the cocaine concentration. Since the supramolecular aptamer fragments/cocaine complex was formed on the electrode surface, the sensing interface strongly affected the sensitivity of the aptasensor. Au/Cx5S/MCE was shown to have good sensitivity within a cocaine detection range of 0.1-20 mu M. Moreover, MCE was shown to improve the sensitivity of the aptasensor greatly. Even without the help of amplification or labeling, cocaine concentrations as low as 100 nM could be easily detected by the impedimetric aptasensor developed. The specificity and regeneration of the cocaine aptasensor were also investigated and satisfactory results were obtained. The developed aptasensor was successfully applied to detect the cocaine in biological fluids. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:65 / 71
页数:7
相关论文
共 50 条
  • [21] Label-free electrochemical aptasensor for the detection of lysozyme
    Rodriguez, Marcela C.
    Rivas, Gustavo A.
    TALANTA, 2009, 78 (01) : 212 - 216
  • [22] A sensitive, label free electrochemical aptasensor for ATP detection
    Li, Wang
    Nie, Zhou
    Xu, Xiahong
    Shen, Qinpeng
    Deng, Chunyan
    Chen, Jinhua
    Yao, Shouzhuo
    TALANTA, 2009, 78 (03) : 954 - 958
  • [23] Label-free Electrochemical Impedance Spectroscopy Aptasensor for Ultrasensitive Detection of Lung Cancer Biomarker Carcinoembryonic Antigen
    Wang, Yawei
    Chen, Lei
    Xuan, Tiantian
    Wang, Jian
    Wang, Xiuwen
    FRONTIERS IN CHEMISTRY, 2021, 9
  • [24] Electrochemical aptasensor for highly sensitive determination of cocaine using a supramolecular aptamer and rolling circle amplification
    Bo Shen
    Jianbo Li
    Wei Cheng
    Yurong Yan
    Renkuan Tang
    Yongguo Li
    Huangxian Ju
    Shijia Ding
    Microchimica Acta, 2015, 182 : 361 - 367
  • [25] Sensitive label-free electrochemical analysis of human IgE using an aptasensor with cDNA amplification
    Lee, Cheng-Yu
    Wu, Kuan-Ying
    Su, Hsiu-Li
    Hung, Huan-Yi
    Hsieh, You-Zung
    BIOSENSORS & BIOELECTRONICS, 2013, 39 (01) : 133 - 138
  • [26] Aptamer-based electrochemical biosensor for label-free voltammetric detection of thrombin and adenosine
    Yan, Fangfang
    Wang, Fang
    Chen, Zilin
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 160 (01) : 1380 - 1385
  • [27] A label-free and sensitive supersandwich electrochemical biosensor for small molecule detection based on target-induced aptamer displacement
    Yang, Xiaohai
    Zhu, Jinqing
    Wang, Qing
    Wang, Kemin
    Yang, Lijuan
    Zhu, Hongzhi
    ANALYTICAL METHODS, 2012, 4 (08) : 2221 - 2223
  • [28] An electrochemical label-free and sensitive thrombin aptasensor based on graphene oxide modified pencil graphite electrode
    Ahour, F.
    Ahsani, M. K.
    BIOSENSORS & BIOELECTRONICS, 2016, 86 : 764 - 769
  • [29] An Effective Label-Free Electrochemical Aptasensor Based on Gold Nanoparticles for Gluten Detection
    Svigelj, Rossella
    Zuliani, Ivan
    Grazioli, Cristian
    Dossi, Nicolo
    Toniolo, Rosanna
    NANOMATERIALS, 2022, 12 (06)
  • [30] Detection of Oxytetracycline Using an Electrochemical Label-Free Aptamer-Based Biosensor
    Akbarzadeh, Sanaz
    Khajehsharifi, Habibollah
    Hajihosseini, Saeedeh
    BIOSENSORS-BASEL, 2022, 12 (07):