共 50 条
A label-free aptasensor for the sensitive and specific detection of cocaine using supramolecular aptamer fragments/target complex by electrochemical impedance spectroscopy
被引:38
|作者:
Zhang, De-Wen
[1
]
Zhang, Fang-Ting
[1
]
Cui, Yi-Ran
[1
]
Deng, Qin-Pei
[1
]
Krause, Steffi
[2
]
Zhou, Ying-Lin
[1
]
Zhang, Xin-Xiang
[1
]
机构:
[1] Peking Univ, Coll Chem, Key Lab Biochem & Mol Engn, BNLMS, Beijing 100871, Peoples R China
[2] Univ London, Sch Engn & Mat Sci, London E1 4NS, England
来源:
基金:
中国国家自然科学基金;
关键词:
Aptamer fragment;
Cocaine;
Supramolecular complex;
Label-free;
Electrochemical impedance spectroscopy;
SENSING PLATFORM;
SMALL MOLECULES;
IMPEDIMETRIC APTASENSOR;
PROTEIN INTERACTIONS;
STRAND DISPLACEMENT;
GOLD NANOPARTICLES;
SENSOR;
BIOSENSOR;
ADENOSINE;
PROBE;
D O I:
10.1016/j.talanta.2012.01.049
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
A simple and label-free aptasensor for sensitive and specific detection of cocaine was developed by measuring the change in electrochemical impedance spectra (EIS), based on the formation of a supramolecular aptamer fragments/substrate complex. An anticocaine aptamer was divided into two fragments, Cx and Cy. Three different sensing interfaces, called Au/Cx5S/MCE, Au/Cy3S/MCE and Au/Cy5S/MCE, were fabricated by immobilizing Cx or Cy on a gold electrode through modifying their 5' or 3' end with a thiolated group followed by the treatment with mercaptoethanol (MCE). The formation of the corresponding supramolecular aptamer fragments/cocaine complex was investigated via monitoring electrochemical impedance spectra in the presence of [Fe(CN)(6)](3-/4-). The interfacial electron transfer resistance (R-et) was found to depend strongly on the cocaine concentration. Since the supramolecular aptamer fragments/cocaine complex was formed on the electrode surface, the sensing interface strongly affected the sensitivity of the aptasensor. Au/Cx5S/MCE was shown to have good sensitivity within a cocaine detection range of 0.1-20 mu M. Moreover, MCE was shown to improve the sensitivity of the aptasensor greatly. Even without the help of amplification or labeling, cocaine concentrations as low as 100 nM could be easily detected by the impedimetric aptasensor developed. The specificity and regeneration of the cocaine aptasensor were also investigated and satisfactory results were obtained. The developed aptasensor was successfully applied to detect the cocaine in biological fluids. (C) 2012 Elsevier B.V. All rights reserved.