Effect of T1-mapping technique and diminished image resolution on quantification of infarct mass and its ability in predicting appropriate ICD therapy

被引:7
作者
Farrag, Nadia A. [1 ]
Ramanan, Venkat [2 ]
Wright, Graham A. [2 ,3 ]
Ukwatta, Eranga [1 ]
机构
[1] Carleton Univ, Dept Syst & Comp Engn, Ottawa, ON K1S 5B6, Canada
[2] Sunnybrook Hlth Sci Ctr, Sunnybrook Res Inst, Toronto, ON M4N 3M5, Canada
[3] Univ Toronto, Dept Med Biophys, Toronto, ON M5G 1L7, Canada
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
cardiac magnetic resonance; MCLE; MOLLI; myocardial infarction; spatial resolution; T1-mapping; SUDDEN CARDIAC DEATH; MAGNETIC-RESONANCE; VENTRICULAR-TACHYCARDIA; MYOCARDIAL-INFARCTION; BORDER ZONE; FIBROSIS; HEART; CARDIOMYOPATHY; HETEROGENEITY;
D O I
10.1002/mp.12840
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeMyocardial infarct (MI) may consist of an infarct core (IC) and a heterogeneous, semi-viable border zone (BZ). Patients with chronic MI in the left ventricular (LV) myocardium are at increased risk of developing ventricular arrhythmias, and may therefore qualify for implantable cardioverter defibrillator (ICD) therapy. Indices based on MI mass, as determined by cardiac magnetic resonance (CMR) imaging, are shown to be sensitive in predicting adverse ventricular arrhythmic events. However, several factors, such as imaging technique and spatial resolution affect the accuracy of MI mass quantification. The aim of this study was to compare the MI masses determined by T1-mapping CMR techniques to those of conventional late Gadolinium-enhanced cardiac magnetic resonance (LGE-CMR) using inversion recovery fast gradient echo (IR-FGRE). We additionally aimed to investigate the effect of diminishing image resolution on quantification of the MI mass and its ability to predict appropriate ICD therapy. MethodsThirty-eight patients with known MI underwent acquisitions of three CMR imaging techniques: the multicontrast late enhancement (MCLE) and modified look-locker inversion recovery (MOLLI) T1-mapping techniques, and conventional inversion recovery fast gradient echo (IR-FGRE) about 20 min after double-dose injection of Gadolinium. We postprocessed images to quantify IC and BZ masses determined by each CMR technique using a full-width half-maximum (FWHM) approach in IR-FGRE images and a fuzzy c-means clustering algorithm for T1-mapping images. To determine the impact of spatial resolution in sensitivity of predicting ICD events, we artificially diminished resolution of MCLE images acquired from a separate group of 27 patients who had been followed up for ICD therapy and compared the MI masses estimated from the original and downsampled MCLE images. ResultsTwelve patients out of 27 (44%) received ICD therapy (i.e., one or more delivered shock) during the follow-up stage. Between each of the three imaging methods, IC masses were not significantly different. Conversely, BZ masses determined by MOLLI were larger compared to those determined by MCLE and IR-FGRE (P value = 0.0022 and 0.0003, respectively). The BZ masses determined by MCLE were not significantly different from those determined by IR-FGRE; however, BZ masses determined by the downsampled MCLE were significantly larger than those determined by IR-FGRE and original MCLE (P value = 0.0033 and 0.0003, respectively). The BZ mass estimated by original MCLE was larger in patients who had received ICD therapy compared to those who did not (P value = 0.044). However, when the spatial resolution of the MCLE images was diminished to that of MOLLI, BZ masses were not significantly different between patients with and without ICD therapy. ConclusionsWhile estimated IC masses were consistent among all three techniques, the estimated BZ masses were not consistent, especially when spatial resolution of images differed between the techniques. In particular, our study showed that diminished image resolution caused an increase in estimation of the BZ mass, likely due to partial volume effects, which led to a reduced sensitivity in the prediction of appropriate ICD therapy.
引用
收藏
页码:1577 / 1585
页数:9
相关论文
共 22 条
[11]   Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction [J].
Moss, AJ ;
Zareba, W ;
Hall, WJ ;
Klein, H ;
Wilber, DJ ;
Cannom, DS ;
Daubert, JP ;
Higgins, SL ;
Brown, MW ;
Andrews, ML .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (12) :877-883
[12]   Implantable Cardioverter-Defibrillators after Myocardial Infarction [J].
Myerburg, Robert J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2008, 359 (21) :2245-2253
[13]  
Pop M, 2017, 9 INT C FIMH 2017 TO, P13
[14]   High-Resolution 3-D T1*-Mapping and Quantitative Image Analysis of GRAY ZONE in Chronic Fibrosis [J].
Pop, Mihaela ;
Ramanan, Venkat ;
Yang, Franklin ;
Zhang, Li ;
Newbigging, Susan ;
Ghugre, Nilesh R. ;
Wright, Graham A. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (12) :2930-2938
[15]   Quantification of fibrosis in infarcted swine hearts by ex vivo late gadolinium-enhancement and diffusion-weighted MRI methods [J].
Pop, Mihaela ;
Ghugre, Nilesh R. ;
Ramanan, Venkat ;
Morikawa, Lily ;
Stanisz, Greg ;
Dick, Alexander J. ;
Wright, Graham A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (15) :5009-5028
[16]  
Schelbert EB, 2015, CLIN APPL T1 MAPPING
[17]   Late Gadolinium-Enhancement Cardiac Magnetic Resonance Identifies Postinfarction Myocardial Fibrosis and the Border Zone at the Near Cellular Level in Ex Vivo Rat Heart [J].
Schelbert, Erik B. ;
Hsu, Li-Yueh ;
Anderson, Stasia A. ;
Mohanty, Bibhu D. ;
Karim, Syed M. ;
Kellman, Peter ;
Aletras, Anthony H. ;
Arai, Andrew E. .
CIRCULATION-CARDIOVASCULAR IMAGING, 2010, 3 (06) :743-752
[18]   Infarct tissue heterogeneity by magnetic resonance imaging identifies enhanced cardiac arrhythmia susceptibility in patients with left ventricular dysfunction [J].
Schmidt, Andre ;
Azevedo, Clerio F. ;
Cheng, Alan ;
Gupta, Sandeep N. ;
Bluemke, David A. ;
Foo, Thomas K. ;
Gerstenblith, Gary ;
Weiss, Robert G. ;
Marban, Eduardo ;
Tomaselli, Gordon F. ;
Lima, Joao A. C. ;
Wu, Katherine C. .
CIRCULATION, 2007, 115 (15) :2006-2014
[19]   Cardiovascular magnetic resonance characterization of peri-infarct zone remodeling following myocardial infarction [J].
Schuleri, Karl H. ;
Centola, Marco ;
Evers, Kristine S. ;
Zviman, Adam ;
Evers, Robert ;
Lima, Joao A. C. ;
Lardo, Albert C. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2012, 14
[20]   T1 Mapping Basic Techniques and Clinical Applications [J].
Taylor, Andrew J. ;
Salerno, Michael ;
Dharmakumar, Rohan ;
Jerosch-Herold, Michael .
JACC-CARDIOVASCULAR IMAGING, 2016, 9 (01) :67-81