UPGRADING THE PERFORMANCE OF HEAT RECOVERY UNIT CONTAINING HEAT PIPES BY USING A HYBRID (CuO plus ZnO)/WATER NANOFLUID

被引:12
作者
Sozen, Adnan [1 ]
Martin, Kerim [1 ]
Aytac, Ipek [2 ]
Filiz, Cagdas [3 ]
机构
[1] Gazi Univ, Ankara, Turkey
[2] Univ Turkish Aeronaut Assoc, Ankara, Turkey
[3] Kilis 7 Aralik Univ, Kilis, Turkey
关键词
heat pipe; heat recovery; hybrid nanofluid;
D O I
10.1615/HeatTransRes.2020035393
中图分类号
O414.1 [热力学];
学科分类号
摘要
Waste heat recovery system is a system using for preheating fresh air needed in industrial and waste heat plants. The aim of this study is to improve the performance of a heat recovery unit by using a heat exchanger consisting of a heat pipe which uses a (CuO + ZnO)/water hybrid nanofluid as a working fluid. As is known, the nanofluid in the heat pipe is able to evaporate at a temperature lower than the temperature of the base fluid, so the heat recovery unit will also be provided to benefit from the waste heat at lower temperatures. Thus, the temperature range of the heat recovery unit will be increased. The optimum conditions for the evaporation of hybrid nanofluid in the evaporator region of the heat pipe were investigated by performing experiments at different temperatures and flow rates of the waste heat. Similar conditions were made in a cold fluid, and the optimum conditions for condensing the nanofluid in the condenser region were investigated. Experiments were performed at 2 different cold air flows (30 g/s and 60 g/s), 3 different hot air flows (50 g/s, 70 g/s, and 90 g/s) and 2 different heating powers (1000 W and 2000 W). Thus, optimum values of temperature and flow were found at all Re numbers on the hot- and cold-fluid sides, and it was helped to determine the operating temperature ranges of the heat recovery unit. The efficiency improvement rates in the heat pipe were between 14% and 73%. The best result was achieved when the cold-air duct Reynolds number was 6700 and the hot-air duct Reynolds number was 11,250. The use of the hybrid nanofluid at all Re numbers reduced thermal resistance in the heat pipe. The maximum reduction rate in thermal resistance was achieved to be 40.4% compared to pure water when the cold-air duct Reynolds number was 12,400. As a result, the efficiency of the heat tension recovery unit increased.
引用
收藏
页码:1289 / 1300
页数:12
相关论文
共 8 条
[1]  
Aramesh M, 2019, P I MECH ENG A-POWER, V1, P1
[2]   Towards hybrid nanofluids: Preparation, thermophysical properties, applications, and challenges [J].
Babar, Hamza ;
Ali, Hafiz Muhammad .
JOURNAL OF MOLECULAR LIQUIDS, 2019, 281 :598-633
[3]  
Çiftçi E, 2016, J POLYTECH, V19, P367
[4]   Free convection of hybrid Al2O3-Cu water nanofluid in a differentially heated porous cavity [J].
Mehryan, S. A. M. ;
Kashkooli, Farshad M. ;
Ghalambaz, Mohammad ;
Chamkha, Ali J. .
ADVANCED POWDER TECHNOLOGY, 2017, 28 (09) :2295-2305
[5]   Nanofluid flow and heat transfer between parallel plates considering Brownian motion using DTM [J].
Sheikholeslami, Mohsen ;
Ganji, Davood Domiri .
COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2015, 283 :651-663
[6]   Experimental and numerical study on enhancement of heat transfer characteristics of a heat pipe utilizing aqueous clinoptilolite nanofluid [J].
Sozen, Adnan ;
Guru, Metin ;
Khanlari, Ataollah ;
Ciftci, Erdem .
APPLIED THERMAL ENGINEERING, 2019, 160
[7]   A comparative investigation on the effect of fly-ash and alumina nanofluids on the thermal performance of two-phase closed thermo-syphon heat pipes [J].
Sozen, Adnan ;
Menlik, Tayfun ;
Guru, Metin ;
Boran, Kurtulus ;
Kilic, Faruk ;
Aktas, Mustafa ;
Cakir, M. Tarik .
APPLIED THERMAL ENGINEERING, 2016, 96 :330-337
[8]  
Takabi B., 2014, ADV MECH ENG, V6, P1