Evaluation of the Risk of Laboratory Microbial Contamination during Routine Testing in Automated Clinical Chemistry and Microbiology Laboratories

被引:8
作者
Farnsworth, Christopher W. [1 ]
Wallace, Meghan A. [1 ]
Liu, Albert [1 ]
Gronowski, Ann M. [1 ]
Burnham, Carey-Ann D. [1 ]
Yarbrough, Melanie L. [1 ]
机构
[1] Washington Univ, Dept Pathol & Immunol, Sch Med, 425 So Euclid Ave,Campus Box 8118, St Louis, MO 63110 USA
关键词
UNITED-STATES; INFECTIONS;
D O I
10.1093/clinchem/hvaa128
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: Every clinical specimen is potentially infectious, but data regarding risk for contamination of the laboratory environment during routine testing are scarce. We assessed contamination during routine sample analysis in automated clinical chemistry and microbiology laboratories. METHODS: A fluorescent marker was applied to specimen container exteriors to assess the impact of gross contamination. Nonpathogenic MS2 virus was added to remnant blood, urine, and ESwab matrices as a biomarker of cross-contamination. Samples were processed and analyzed using Roche Cobas 8100 and ISE, c502, e602, and c702 modules (blood) and BD Kiestra total laboratory automation (blood, urine, ESwabs) over 3 experiments. Fluorescence transfer to laboratory surfaces and personnel was visualized using ultraviolet light. Surfaces were swabbed and assessed for MS2 cross-contamination by RT-PCR. Adherence to standard precautions by laboratory staff was assessed by observation. RESULTS: Fluorescence was observed on 49 of 165 (30%) laboratory surfaces and personnel and 21 of 93 (23%) total laboratory automation instruments. Fluorescence transferred most frequently to gloves (31/40), computer accessories (9/18), and specimen loading racks (12/12). None of 123 areas swabbed were positive for MS2. Improper personal protective equipment use occurred at a rate of 0.36 and 0.15 events per staff per hour in the chemistry and microbiology laboratories, respectively. Hand-washing compliance was observed for 61 of 132 (46%) staff members evaluated. CONCLUSIONS: Analysis of grossly contaminated specimens on automated chemistry and microbiology equipment elicits a low likelihood of instrument contamination. However, handling contaminated specimen containers can result in contamination of environmental laboratory surfaces, representing a source of risk that is heightened by low adherence to appropriate personal protective equipment.
引用
收藏
页码:1190 / 1199
页数:10
相关论文
共 29 条
[1]  
[Anonymous], 2020, N. Engl. J. Med., DOI DOI 10.1056/NEJMoa2001316
[2]   Performance-Enhancing Drugs on the Web: A Growing Public-Health Issue [J].
Brennan, Brian P. ;
Kanayama, Gen ;
Pope, Harrison G., Jr. .
AMERICAN JOURNAL ON ADDICTIONS, 2013, 22 (02) :158-161
[3]   Bloodborne Viral Pathogen Contamination in the Era of Laboratory Automation [J].
Bryan, Andrew ;
Cook, Linda ;
Atienza, Ederlyn E. ;
Kuypers, Jane ;
Cent, Anne ;
Baird, Geoffrey S. ;
Coombs, Robert W. ;
Jerome, Keith R. ;
Wener, Mark H. ;
Butler-Wu, Susan M. .
CLINICAL CHEMISTRY, 2016, 62 (07) :973-981
[4]   Are We There Yet? Laboratory Preparedness for Emerging Infectious Diseases [J].
Burnham, Carey-Ann D. ;
Kwon, Jennie H. ;
Burd, Eileen M. ;
Campbell, Sheldon ;
Iwen, Peter C. ;
Miller, Melissa B. .
CLINICAL CHEMISTRY, 2017, 63 (04) :807-811
[5]  
CDC, 2019, VIRAL HEPATITIS
[6]  
CDC, REC LAB HIV TEST ALG
[7]  
CDC, EB VIR DIS LAB PERS
[8]  
Chevalier MS, 2014, MMWR-MORBID MORTAL W, V63, P1087
[9]   Assessment of Test Performance and Potential for Environmental Contamination Associated with a Point-of-Care Molecular Assay for Group A Streptococcus in an End User Setting [J].
Donato, Leslie J. ;
Myhre, Nikki K. ;
Murray, Martha A. ;
McDonah, Margaret R. ;
Myers, Jane F. ;
Maxson, Julie A. ;
Meek, Alicia M. ;
Espy, Mark J. ;
Furst, Joseph W. ;
Karon, Brad S. ;
Binnicker, Matthew J. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2019, 57 (02)
[10]   POTENTIAL FOR LABORATORY EXPOSURES TO BIOHAZARDOUS AGENTS FOUND IN BLOOD [J].
EVANS, MR ;
HENDERSON, DK ;
BENNETT, JE .
AMERICAN JOURNAL OF PUBLIC HEALTH, 1990, 80 (04) :423-427