A Novel Highly Porous Silica and Chitosan-Based Hemostatic Dressing Is Superior to HemCon and Gauze Sponges

被引:62
作者
Englehart, Michael S. [1 ]
Cho, S. David [1 ]
Tieu, Brandon H. [1 ]
Morris, Melanie S. [1 ]
Underwood, Samantha J. [1 ]
Karahan, Ayhan [1 ]
Muller, Patrick J. [1 ]
Differding, Jerome A. [1 ]
Farrell, David H. [1 ]
Schreiber, Martin A. [1 ]
机构
[1] Oregon Hlth & Sci Univ, Dept Surg, Trauma Crit Care Sect, Portland, OR 97239 USA
来源
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE | 2008年 / 65卷 / 04期
关键词
Trauma; Hemostatic dressing; HemCon; Gauze; Hemorrhagic shock;
D O I
10.1097/TA.0b013e318187800b
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Hemostatic dressings have become increasingly popular as the optimal initial treatment for severe hemorrhage. The purpose of this study was to compare the hemostatic properties of a novel highly porous silica and chitosanbased dressing (TraumaStat) to HemCon, and gauze dressing in a severe groin injury model in swine. Methods. Thirty swine were blindly randomized to receive TraumaStat, HemCon, or standard gauze dressing for hemostatic control. A complex groin injury involving complete transaction of the femoral artery and vein was made. After 30 seconds of uncontrolled hemorrhage, the randomized dressing was applied and pressure was held for 5 minutes. Fluid resuscitation was initiated to achieve and maintain the baseline mean arterial pressure and the wound was inspected for bleeding. Failure of hemostasis was defined as pooling of blood outside of the wound. Animals were then monitored for 120 minutes and surviving animals were euthanized. Results: Blood loss before treatment was similar between groups (p > 0.1). TraumaStat had one failure, compared with five for gauze, and eight for HemCon (p = 0.005, TraumaStat vs. HemCon). TraumaStat significantly reduced median blood loss when compared with both HemCon and gauze (117 vs. 774 and 268 mL respectively, p < 0.05). At study conclusion, TraumaStat animals had a greater median hematocrit than both HemCon (24 vs. 19, p = 0.033), and gauze (24 vs. 19, p = 0.049) animals. Median volume of fluid resuscitation and mortality were not different between groups (p > 0.1). Conclusions: TraumaStat was superior to HemCon and gauze dressings in controlling bleeding from a severe groin injury. TraumaStat may be a better hemostatic dressing for control of active hemorrhage than current standards of care.
引用
收藏
页码:884 / 890
页数:7
相关论文
共 16 条
[1]   Comparison of hemorrhage control agents applied to lethal extremity arterial hemorrhages in swine [J].
Acheson, EM ;
Kheirabadi, BS ;
Deguzman, R ;
Dick, EJ ;
Holcomb, JB .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 59 (04) :865-874
[2]   Application of a zeolite hemostatic agent achieves 100% survival in a lethal model of complex groin injury in swine [J].
Alam, HB ;
Chen, Z ;
Jaskille, A ;
Querol, RILC ;
Koustova, E ;
Inocencio, R ;
Conran, R ;
Seufert, A ;
Ariaban, N ;
Toruno, K ;
Rhee, P .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2004, 56 (05) :974-983
[3]  
*AM COLL SURG COMM, 1997, ADV TRAUM LIF SUPP C, P87
[4]  
Bonne RJ, 1999, REDUCING BURDEN INJU
[5]   FLUID RESUSCITATION FOLLOWING INJURY - RATIONALE FOR USE OF BALANCED SALT-SOLUTIONS [J].
CARRICO, CJ ;
CANIZARO, PC ;
SHIRES, GT .
CRITICAL CARE MEDICINE, 1976, 4 (02) :46-54
[6]   A profile of combat injury [J].
Champion, HR ;
Bellamy, RF ;
Roberts, CP ;
Leppaniemi, A .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2003, 54 (05) :S13-S19
[7]  
Jewelewicz DD, 2003, J TRAUMA, V55, P275, DOI 10.1097/01.TA.0000079375.69610.89
[8]   Resuscitation with normal saline (NS) vs. lactated ringers (LR) modulates hypercoagulability and leads to increased blood loss in an uncontrolled hemorrhagic shock swine model [J].
Kiraly, Laszlo N. ;
Differding, Jerome A. ;
Enomoto, T. Miko ;
Sawai, Rebecca S. ;
Muller, Patrick J. ;
Diggs, Brian ;
Tieu, Brandon H. ;
Englehart, Michael S. ;
Underwood, Samantha ;
Wiesberg, Tracy T. ;
Schreiber, Martin A. .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 61 (01) :57-64
[9]   Making sense of the preclinical literature on advanced hemostatic products [J].
Pusateri, AE ;
Holcomb, JB ;
Kheirabadi, BS ;
Alam, HB ;
Wade, CE ;
Ryan, KL .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 60 (03) :674-682
[10]   Advanced hemostatic dressing development program: Animal model selection criteria and results of a study of nine hemostatic dressings in a model of severe large venous hemorrhage and hepatic injury in swine [J].
Pusateri, AE ;
Modrow, HE ;
Harris, RA ;
Holcomb, JB ;
Hess, JR ;
Mosebar, RH ;
Reid, TJ ;
Nelson, JH ;
Goodwin, CW ;
Fitzpatrick, GM ;
McManus, AT ;
Zolock, DT ;
Sondeen, JL ;
Cornum, RL ;
Martinez, RS .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2003, 55 (03) :518-526