Regularized Spectral Log Difference Technique for Ultrasonic Attenuation Imaging

被引:70
作者
Coila, Andres L. [1 ,2 ]
Lavarello, Roberto [1 ]
机构
[1] Pontificia Univ Catolica Peru, Dept Ingn, Lima 32, Peru
[2] Univ Illinois, Dept Elect & Comp Engn, Champaign, IL 61801 USA
关键词
Attenuation imaging; quantitative ultrasound (QUD); tissue characterization; total variation regularization; REFERENCE-PHANTOM; BACKSCATTER COEFFICIENTS; LIVER-DISEASE; SIGNALS; SLOPE; RECONSTRUCTION; PROPAGATION; SCATTERING; INVIVO; MUSCLE;
D O I
10.1109/TUFFC.2017.2719962
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The attenuation coefficient slope (ACS) has the potential to be used for tissue characterization and as a diagnostic ultrasound tool, hence complementing B-mode images. The ACS can be valuable for the estimation of other ultrasound parameters such as the backscatter coefficient. There is a well-known tradeoff between the precision of the estimated ACS values and the data block size used in the spectral-based techniques such as the spectral-log difference (SLD). This tradeoff limits the practical usefulness of the spectral-based attenuation imaging techniques. In this paper, the regularized SLD (RSLD) technique is presented in detail, and evaluated with simulations and experiments with physical phantoms, ex vivo and in vivo. The RSLD technique allowed decreasing estimation variance when using small data block sizes, i.e., fivefold reduction in the standard deviation of percentage error when using data block sizes larger than 20 lambda x 20 lambda and more than a tenfold reduction when using 10 lambda x 10 lambda data blocks. The precision improvement was obtained without sacrificing estimation accuracy (i.e., estimation bias improved in 70% of the cases by 10% of the ground truth-value on average while degraded in 30% of the cases by 3% of the ground truth-value on average). The improvements in precision allowed for better differentiation of inclusions especially when using small data blocks (i.e., smaller than 20 lambda x 20 lambda) where the contrast-to-noise ratio improved by an order of magnitude on average. The results suggest that the RSLD allows for the reconstruction of attenuation coefficient images with an improved tradeoff between spatial resolution and estimation precision.
引用
收藏
页码:378 / 389
页数:12
相关论文
共 47 条
[1]  
[Anonymous], FOUND TRENDS MACH LE
[2]  
[Anonymous], 2013, J ELECT COMPUTER ENG
[3]  
[Anonymous], 2002, COMPUTATIONAL METHOD
[4]   Estimating the Total Ultrasound Attenuation Along the Propagation Path by Applying Multiple Filters to Backscattered Echoes From a Single Spherically Focused Source [J].
Bigelow, Timothy A. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (04) :900-907
[5]   Reconstruction of ultrasonic sound velocity and attenuation coefficient using linear arrays: Clinical assessment [J].
Chang, Chen-Han ;
Huang, Sheng-Wen ;
Yang, Hsin-Chia ;
Chou, Yi-Hong ;
Li, Pai-Chi .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (11) :1681-1687
[6]   The measurement of backscatter coefficient from a broadband pulse-echo system: A new formulation [J].
Chen, XC ;
Phillips, D ;
Schwarz, KQ ;
Mottley, JG ;
Parker, KJ .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (02) :515-525
[7]   A REGULARIZATION APPROACH FOR ULTRASONIC ATTENUATION IMAGING [J].
Coila, Andres ;
Rouyer, Julien ;
Zenteno, Omar ;
Lavarello, Roberto .
2016 IEEE 13TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2016, :469-472
[8]   FREQUENCY-DEPENDENCE OF ULTRASOUND ATTENUATION AND BACKSCATTER IN BREAST-TISSUE [J].
DASTOUS, FT ;
FOSTER, FS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1986, 12 (10) :795-808
[9]   Attenuation coefficient measurement in the thyroid [J].
Fujii, Y ;
Taniguchi, N ;
Itoh, K ;
Omoto, K .
JOURNAL OF ULTRASOUND IN MEDICINE, 2003, 22 (10) :1067-1073
[10]   A new method for attenuation coefficient measurement in the liver - Comparison with the spectral shift central frequency method [J].
Fujii, Y ;
Taniguchi, N ;
Itoh, K ;
Shigeta, K ;
Wang, Y ;
Tsao, JW ;
Kumasaki, K ;
Itoh, T .
JOURNAL OF ULTRASOUND IN MEDICINE, 2002, 21 (07) :783-788