Streaking artifacts reduction in four-dimensional cone-beam computed tomography

被引:88
|
作者
Leng, Shuai [4 ]
Zambelli, Joseph [4 ]
Tolakanahalli, Ranjini [1 ]
Nett, Brian [4 ]
Munro, Peter [2 ]
Star-Lack, Joshua [2 ]
Paliwal, Bhudatt [3 ]
Chena, Guang-Hong [5 ]
机构
[1] Univ Wisconsin, Dept Human Oncol, Madison, WI 53792 USA
[2] Varian Med Syst, Palo Alto, CA 94304 USA
[3] Univ Wisconsin, Dept Med Phys & Human Oncol, Madison, WI 53792 USA
[4] Univ Wisconsin, Dept Med Phys, Madison, WI 53792 USA
[5] Univ Wisconsin, Dept Med Phys Radiol & Human Oncol, Madison, WI 53792 USA
基金
美国国家卫生研究院;
关键词
cone-beam CT; image-guided radiation therapy;
D O I
10.1118/1.2977736
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Cone-beam computed tomography (CBCT) using an "on-board" x-ray imaging device integrated into a radiation therapy system has recently been made available for patient positioning, target localization, and adaptive treatment planning. One of the challenges for gantry mounted image-guided radiation therapy (IGRT) systems is the slow acquisition of projections for cone-beam CT (CBCT), which makes them sensitive to any patient motion during the scans. Aiming at motion artifact reduction, four-dimensional CBCT (4D CBCT) techniques have been introduced, where a surrogate for the target's motion profile is utilized to sort the cone-beam data by respiratory phase. However, due to the limited gantry rotation speed and limited readout speed of the on-board imager, fewer than 100 projections are available for the image reconstruction at each respiratory phase. Thus, severe undersampling streaking artifacts plague 4D CBCT images. In this paper, the authors propose a simple scheme to significantly reduce the streaking artifacts. In this method, a prior image is first reconstructed using all available projections without gating, in which static structures are well reconstructed while moving objects are blurred. The undersampling streaking artifacts from static structures are estimated from this prior image volume and then can be removed from the phase images using gated reconstruction. The proposed method was validated using numerical simulations, experimental phantom data, and patient data. The fidelity of stationary and moving objects is maintained, while large gains in streak artifact reduction are observed. Using this technique one can reconstruct 4D CBCT datasets using no more projections than are acquired in a 60 s scan. At the same time, a temporal gating window as narrow as 100 ms was utilized. Compared to the conventional 4D CBCT reconstruction, streaking artifacts were reduced by 60% to 70%. (C) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:4649 / 4659
页数:11
相关论文
共 50 条
  • [1] Streaking Artifacts Reduction in Four-Dimensional Cone-Beam Computed Tomography
    Leng, S.
    Zambelli, J.
    Tolakanahalli, R.
    Nett, B.
    Munro, P.
    Star-Lack, J.
    Paliwal, B.
    Chen, G.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [2] Target displacement evaluation for fluoroscopic and four-dimensional cone-beam computed tomography
    Iramina, H.
    Nakamura, M.
    Iizuka, Y.
    Matsuo, Y.
    Mizowaki, T.
    Hiraoka, M.
    Kanno, I.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S148 - S148
  • [3] Four-dimensional cone-beam computed tomography using an on-board imager
    Li, Tianfang
    Xing, Lei
    Munro, Peter
    McGuinness, Christopher
    Chao, Ming
    Yang, Yong
    Loo, Bill
    Koong, Albert
    MEDICAL PHYSICS, 2006, 33 (10) : 3825 - 3833
  • [4] Streaking artifacts suppression for cone-beam computed tomography with the residual learning in neural network
    Yang, Fuqiang
    Zhang, Dinghua
    Zhang, Hua
    Huang, Kuidong
    Du, You
    Teng, Mingxuan
    NEUROCOMPUTING, 2020, 378 (378) : 65 - 78
  • [5] Enhancement of four-dimensional cone-beam computed tomography by compressed sensing with Bregman iteration
    Choi, Kihwan
    Fahimian, Benjamin P.
    Li, Tianfang
    Suh, Tae-Suk
    Lei, Xing
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2013, 21 (02) : 177 - 192
  • [6] Four-dimensional cone-beam computed tomography-guided radiotherapy for gastric lymphoma
    Toya, Ryo
    Saito, Tetsuo
    Shimohigashi, Yoshinobu
    Yotsuji, Yohei
    Matsuyama, Tomohiko
    Watakabe, Takahiro
    Kai, Yudai
    Yamashita, Yasuyuki
    Oya, Natsuo
    JAPANESE JOURNAL OF RADIOLOGY, 2018, 36 (02) : 159 - 163
  • [7] Enhancement of Four-Dimensional Cone-Beam Computed Tomography by Compressed Sensing with Bregman Iteration
    Choi, K.
    Fahimian, B.
    Li, T.
    Suh, T.
    Xing, L.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [8] Four-dimensional cone-beam computed tomography-guided radiotherapy for gastric lymphoma
    Ryo Toya
    Tetsuo Saito
    Yoshinobu Shimohigashi
    Yohei Yotsuji
    Tomohiko Matsuyama
    Takahiro Watakabe
    Yudai Kai
    Yasuyuki Yamashita
    Natsuo Oya
    Japanese Journal of Radiology, 2018, 36 : 159 - 163
  • [9] Performance studies of four-dimensional cone beam computed tomography
    Qi, Zhihua
    Chen, Guang-Hong
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (20): : 6709 - 6721
  • [10] Joint Motion Estimation and Compensation for Four-Dimensional Cone-Beam Computed Tomography Image Reconstruction
    Mo, Ying
    Liu, Jia
    Li, Qian
    Yu, Jiahong
    Zhang, Kunpeng
    Gao, Yang
    Zhang, Hua
    IEEE ACCESS, 2021, 9 (09): : 147559 - 147569