Enzymeless electrochemical detection of hydrogen peroxide at Pd nanoparticles/porous graphene

被引:31
|
作者
Xue, Wanyi [1 ]
Bo, Xiangjie [1 ]
Zhou, Ming [1 ]
Guo, Liping [1 ]
机构
[1] Northeast Normal Univ, Dept Chem, Key Lab Nanobiosensing & Nanobioanal Univ Jilin P, 5268 Renmin St, Changchun 130024, Jilin Province, Peoples R China
基金
中国国家自然科学基金;
关键词
Pd nanoparticle; Porous graphene; Hydrogen peroxide; Nonenzymatic sensor; One-step reduction; 3-DIMENSIONAL GRAPHENE; POROUS GRAPHENE; BIOLOGICAL ENVIRONMENTS; HORSERADISH-PEROXIDASE; NONENZYMATIC DETECTION; NANOPOROUS GRAPHENE; CARBON NANOFIBERS; GLUCOSE DETECTION; SENSING PLATFORM; FACILE SYNTHESIS;
D O I
10.1016/j.jelechem.2016.05.036
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, Pd nanoparticles/porous graphene (Pd/PGR) is prepared by simultaneous reduction of graphene oxide (GO) and Pd precursor in sodium borohydride (NaBH4) solutions at the electrode surface. In this preparation, the positively charged ZnO with high isoelectric point is used as templates for the adsorption of negatively charged GO in water. Then, the poly(diallyldimethylammonium chloride) (PDDA) is added into the ZnO/GO through the electrostatic interaction between the negative charge of GO and positive charge of PDDA. Subsequently, PDDA/ZnO/GO is employed as a support material for the adsorption of chloropalladic acid ions (PdCl42-), via the self-assembly between the negative Pd precursor and positively charged functional groups of PDDA. One-step-reduction of Pd precursor/PDDA/ZnO/GO in NaBH4 solutions and the subsequent removal of the ZnO produce Pd/PDDA/PGR with a porous structure at the electrode surface. With a porous morphology and large surface area for both efficient exposure of Pd nanoparticles and enhanced electrolyte-reactant diffusion, a sensitive enzymeless sensor of hydrogen peroxide (H2O2) is constructed. Compared with the nonporous Pd/PDDA/GR, the Pd/PDDA/PGR displays high electrocatalytic activity towards H2O2, exhibiting a high sensitivity of 57.7 mu A mM(-1) and low detection limit of 0.9 mu M towards the reduction of H2O2. The improved activity and simple preparation method makes Pd/PDDA/PGR promising for being developed as an attractive robust and new electrode material for electrochemical sensor and biosensor fabrication. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:204 / 211
页数:8
相关论文
共 50 条
  • [41] Gold nanoparticles plated porous silicon nanopowder for nonenzymatic voltammetric detection of hydrogen peroxide
    Rashed, Md. A.
    Harraz, Farid A.
    Faisal, M.
    El-Toni, Ahmed Mohamed
    Alsaiari, Mabkhoot
    Al-Assiri, M. S.
    ANALYTICAL BIOCHEMISTRY, 2021, 615
  • [42] Au nanoparticles decorated graphene/nickel foam nanocomposite for sensitive detection of hydrogen peroxide
    Wang, Xiaojuan
    Guo, Xinli
    Chen, Jian
    Ge, Chuang
    Zhang, Hongyi
    Liu, Yuanyuan
    Zhao, Li
    Zhang, Yao
    Wang, Zengmei
    Sun, Litao
    JOURNAL OF MATERIALS SCIENCE & TECHNOLOGY, 2017, 33 (03) : 246 - 250
  • [43] Green synthesis of silver nanoparticles on nitrogen-doped graphene for hydrogen peroxide detection
    Tian, Ye
    Wang, Fengli
    Liu, Yanxia
    Pang, Fu
    Zhang, Xiao
    ELECTROCHIMICA ACTA, 2014, 146 : 646 - 653
  • [44] Au nanoparticles decorated graphene/nickel foam nanocomposite for sensitive detection of hydrogen peroxide
    Xiaojuan Wang
    Xinli Guo
    Jian Chen
    Chuang Ge
    Hongyi Zhang
    Yuanyuan Liu
    Li Zhao
    Yao Zhang
    Zengmei Wang
    Litao Sun
    JournalofMaterialsScience&Technology, 2017, 33 (03) : 246 - 250
  • [45] Hierarchical Gadolinium Oxide Microspheres for Enzymeless Electro-biosensors in Hydrogen Peroxide Dynamic Detection
    Yan, Yibo
    Zhao, Jun
    Luo, Jianqiang
    Lee, Jong-Min
    CHEMELECTROCHEM, 2017, 4 (02): : 272 - 277
  • [46] In Vivo Electrochemical Detection of Hydrogen Peroxide and Dopamine
    Zhang Shuai
    Feng Tao-Tao
    Zhang Li
    Zhang Mei-Ning
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 47 (10) : 1664 - 1670
  • [47] Ratiometric electrochemical detection of hydrogen peroxide and glucose
    Goggins, Sean
    Apsey, Ellen A.
    Mahon, Mary F.
    Frost, Christopher G.
    ORGANIC & BIOMOLECULAR CHEMISTRY, 2017, 15 (11) : 2459 - 2466
  • [48] Novel determination of hydrogen peroxide by electrochemically reduced graphene oxide grafted with aminothiophenol-Pd nanoparticles
    You, Jung-Min
    Kim, Daekun
    Kim, Seul Ki
    Kim, Min-Su
    Han, Hyoung Soon
    Jeon, Seungwon
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 178 : 450 - 457
  • [49] Electrocatalytic Reduction of Hydrogen Peroxide and Its Non-Enzymatic Electrochemical Detection Using Silver Nanoparticles Anchored on Reduced Graphene Oxide
    Ikhsan, Nurul Izrini
    Rameshkumar, Perumal
    Yusoff, Norazriena
    Huang, Nay Ming
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2019, 19 (11) : 7054 - 7063
  • [50] One-step electrodeposition synthesis of silver-nanoparticle-decorated graphene on indium-tin-oxide for enzymeless hydrogen peroxide detection
    Golsheikh, A. Moradi
    Huang, N. M.
    Lim, H. N.
    Zakaria, R.
    Yin, Chun-Yang
    CARBON, 2013, 62 : 405 - 412