Stent-assisted coiling of an acutely ruptured large aneurysm of the internal carotid artery: Case report

被引:0
作者
Tone, O [1 ]
Tomita, H [1 ]
Tamaki, M [1 ]
Akimoto, H [1 ]
Shigeta, K [1 ]
Fujii, M [1 ]
机构
[1] Musashino Red Cross Hosp, Dept Neurosurg, Musashino, Tokyo 1808610, Japan
来源
NEUROLOGICAL SURGERY | 2006年 / 34卷 / 05期
关键词
large cerebral aneurysm; subarachnoid hemorrhage; stent-assisted coiling; coronary stent; Guglielmi detachable coil;
D O I
暂无
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
A 48-year-old female was referred to our hospital for the management of a ruptured 22-mm-diameter internal carotid aneurysm, located immediately distal to the ophthalmic artery. The right internal carotid artery was completely involved in the aneurysm. Because the right carotid siphon was relatively nontortuous stent-assisted coiling of the aneurysm was attempted 4 days after subarachnoid hemorrhage. A new coil-type coronary stent, a DRIVER stent, was deployed after microcatheter insertion into the aneurysm dome under systemic heparinization, followed by dome packing using Guglielmi detachable coils. Systemic heparinization was continued for 18 hours postoperatively, and aspirin (100 mg/day) was administered orally immediately after the embolization. However, 4 hours after heparin administration cessation, left hemiparesis became apparent. Immediate magnetic resonance angiography revealed a right internal carotid artery occlusion. Diffusion-weighted images demonstrated ischemic spots in the watershed zones of the right cerebral hemisphere. Following an immediate thrombolysis of the right internal carotid artery, systemic heparinization was continued for 5 days, and aspirin and ticlopidine were administrated orally. The patient was discharged on day 37, following the recovery from left hemiparesis within ten days. A DRIVER stent is a low profile coil-type coronary stent, which can be used for the stent-assisted coiling of large internal carotid aneurysms, located distal to the carotid siphon. It seems necessary to continue systemic heparinization for more than 2 days and to administer increased dose or two types of antiplatelet after the stent-assisted coiling of large cerebral aneurysms.
引用
收藏
页码:505 / 511
页数:7
相关论文
共 50 条
  • [41] The safety and efficacy of low-dosage tirofiban for stent-assisted coiling of ruptured intracranial aneurysms
    Yan, Yazhou
    He, Xiaowu
    Fang, Yibin
    Xu, Yi
    Hong, Bo
    Liu, Jianmin
    Huang, Qinghai
    NEUROSURGICAL REVIEW, 2021, 44 (04) : 2211 - 2218
  • [42] Comparison of Neuroform Atlas Stent-Assisted Coiling and Coiling Alone in Ruptured Intracranial Aneurysms: A Propensity Score Matching Analysis
    Yi, Ho Jun
    Shin, Dong-Seong
    Kim, Bum-Tae
    Lee, Dong Hoon
    Sung, Jae Hoon
    NEUROSURGERY, 2023, 92 (03) : 607 - 614
  • [43] Internal Trapping of an Acutely Ruptured Dissecting Aneurysm of a Dominant Vertebral Artery Following Balloon Test Occlusion: A Case Report
    Ogishima, Takahiro
    Tone, Osamu
    Sato, Yohei
    Tamaki, Masashi
    JOURNAL OF NEUROENDOVASCULAR THERAPY, 2022, 16 (09) : 474 - 480
  • [44] Progressive Occlusion of Aneurysms in Stent-assisted Coiling of Ruptured Wide-necked Intracranial Aneurysms
    Wu, Jing
    Peng, Tangming
    Liu, Aihua
    Qian, Zenghui
    Kang, Huibin
    Li, Youxiang
    Wu, Zhongxue
    JOURNAL OF NEUROLOGICAL SCIENCES-TURKISH, 2014, 31 (04): : 752 - 760
  • [45] Safety and efficacy of stent-assisted coiling ruptured intracranial aneurysms: A single-center experience
    Zhang, Deng-Xiang
    Luo, Chao-Bao
    Lee, Chien-Hui
    TZU CHI MEDICAL JOURNAL, 2025, 37 (02): : 189 - 197
  • [46] The safety and efficacy of low-dosage tirofiban for stent-assisted coiling of ruptured intracranial aneurysms
    Yazhou Yan
    Xiaowu He
    Yibin Fang
    Yi Xu
    Bo Hong
    Jianmin Liu
    Qinghai Huang
    Neurosurgical Review, 2021, 44 : 2211 - 2218
  • [47] Safety of stent-assisted coiling for the treatment of wide-necked ruptured aneurysm: A systematic literature review and meta-analysis of prevalence
    Bsat, Shadi
    Bsat, Ayman
    Tamim, Hani
    Chanbour, Hani
    Alomari, Safwan Omar
    El Houshiemy, Mohamad Nabih
    Moussalem, Charbel
    Omeis, Ibrahim
    INTERVENTIONAL NEURORADIOLOGY, 2020, 26 (05) : 547 - 556
  • [48] De Novo Vertebral Artery Dissection after Endovascular Trapping for Ruptured Dissecting Internal Carotid Artery Aneurysm: Case Report
    Horie, Nobutaka
    Sadakata, Eisaku
    Izumo, Tsuyoshi
    Hayashi, Kentaro
    Morikawa, Minoru
    Nagata, Izumi
    NEUROLOGIA MEDICO-CHIRURGICA, 2015, 55 (06) : 524 - 527
  • [49] Bifurcated Aneurysm Location Predicts In-Stent Stenosis After Neuroform-EZ Stent-Assisted Coiling for Intracranial Aneurysm
    You, Wei
    Feng, Junqiang
    Ge, Huijian
    Jin, Hengwei
    Liu, Peng
    Li, Youxiang
    Jiang, Yuhua
    Liu, Xinke
    FRONTIERS IN NEUROLOGY, 2022, 13
  • [50] Stent-Assisted Coiling Versus Balloon-Assisted Coiling for the Treatment of Ruptured Wide-Necked Aneurysms: A 2-Center Experience
    Vivanco-Suarez, Juan
    Wallace, Adam N.
    Dandapat, Sudeepta
    Lopez, Gloria V.
    Mendez-Ruiz, Aldo
    Kayan, Yasha
    Copelan, Alexander Z.
    Dajles, Andres
    Zevallos, Cynthia B.
    Quispe-Orozco, Darko
    Mendez-Ruiz, Alan
    Galecio-Castillo, Milagros
    Samaniego, Edgar A.
    Farooqui, Mudassir
    Delgado, Josser E.
    Ortega-Gutierrez, Santiago
    STROKE-VASCULAR AND INTERVENTIONAL NEUROLOGY, 2023, 3 (01):