Stent-assisted coiling of an acutely ruptured large aneurysm of the internal carotid artery: Case report

被引:0
作者
Tone, O [1 ]
Tomita, H [1 ]
Tamaki, M [1 ]
Akimoto, H [1 ]
Shigeta, K [1 ]
Fujii, M [1 ]
机构
[1] Musashino Red Cross Hosp, Dept Neurosurg, Musashino, Tokyo 1808610, Japan
来源
NEUROLOGICAL SURGERY | 2006年 / 34卷 / 05期
关键词
large cerebral aneurysm; subarachnoid hemorrhage; stent-assisted coiling; coronary stent; Guglielmi detachable coil;
D O I
暂无
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
A 48-year-old female was referred to our hospital for the management of a ruptured 22-mm-diameter internal carotid aneurysm, located immediately distal to the ophthalmic artery. The right internal carotid artery was completely involved in the aneurysm. Because the right carotid siphon was relatively nontortuous stent-assisted coiling of the aneurysm was attempted 4 days after subarachnoid hemorrhage. A new coil-type coronary stent, a DRIVER stent, was deployed after microcatheter insertion into the aneurysm dome under systemic heparinization, followed by dome packing using Guglielmi detachable coils. Systemic heparinization was continued for 18 hours postoperatively, and aspirin (100 mg/day) was administered orally immediately after the embolization. However, 4 hours after heparin administration cessation, left hemiparesis became apparent. Immediate magnetic resonance angiography revealed a right internal carotid artery occlusion. Diffusion-weighted images demonstrated ischemic spots in the watershed zones of the right cerebral hemisphere. Following an immediate thrombolysis of the right internal carotid artery, systemic heparinization was continued for 5 days, and aspirin and ticlopidine were administrated orally. The patient was discharged on day 37, following the recovery from left hemiparesis within ten days. A DRIVER stent is a low profile coil-type coronary stent, which can be used for the stent-assisted coiling of large internal carotid aneurysms, located distal to the carotid siphon. It seems necessary to continue systemic heparinization for more than 2 days and to administer increased dose or two types of antiplatelet after the stent-assisted coiling of large cerebral aneurysms.
引用
收藏
页码:505 / 511
页数:7
相关论文
共 50 条
  • [21] Hyperperfusion Syndrome after Stent/Coiling of a Ruptured Carotid Bifurcation Aneurysm
    Ecker, Robert D.
    Murray, Richard D.
    Seder, David B.
    NEUROCRITICAL CARE, 2013, 18 (01) : 54 - 58
  • [22] Stent-Assisted Coil Embolization for Acute Ruptured Dissecting Aneurysm at the P2 Segment of the Posterior Cerebral Artery: A Case Report
    Mitsuhashi, Takashi
    Oishi, Hidenori
    Makino, Kensaku
    Tokugawa, Joji
    Fuse, Atsuhito
    Hishii, Makoto
    JOURNAL OF NEUROENDOVASCULAR THERAPY, 2022, 16 (03) : 157 - 162
  • [23] Hyperperfusion Syndrome after Stent/Coiling of a Ruptured Carotid Bifurcation Aneurysm
    Robert D. Ecker
    Richard D. Murray
    David B. Seder
    Neurocritical Care, 2013, 18 : 54 - 58
  • [24] Treatment with Double Neuroform2 Stent Deployment of a Ruptured Fusiform Internal Carotid Artery Aneurysm. A Case Report
    Cho, Chun-Sung
    NEURORADIOLOGY JOURNAL, 2007, 20 (03) : 331 - 336
  • [25] Stent-Assisted Coiling of Aneurysm in a Persistent Primitive Lateral Vertebrobasilar System
    Joshi, Krishna Chaitanya
    Thomas, Anoop
    Jagannatha, Aniruddha T.
    Garg, Deepali
    WORLD NEUROSURGERY, 2016, 86 : 513.e9 - 513.e14
  • [26] Neuroform Atlas stent-assisted coiling of ruptured intracranial aneurysms: A multicenter study
    Russo, Riccardo
    Bradac, Gianni Boris
    Castellan, Lucio
    Gallesio, Ivan
    Garbossa, Diego
    Iannucci, Giuseppe
    Mardighian, Dikran
    Menozzi, Roberto
    Pitrone, Antonio
    Romano, Giuseppe
    Venturi, Fabrizio
    Bergui, Mauro
    JOURNAL OF NEURORADIOLOGY, 2021, 48 (06) : 479 - 485
  • [27] Endovascular Management of Cranial Artery Dissection with Stent Placement and Stent-assisted Coiling
    Dion-Cloutier, Philippe
    Tampieri, Donatella
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2011, 62 (03): : 203 - 208
  • [28] Comparison of Stent-Assisted Coiling and Balloon-Assisted Coiling in the Treatment of Ruptured Wide-Necked Intracranial Aneurysms in the Acute Period
    Cai, Kefu
    Zhang, Yunfeng
    Shen, Lihua
    Ni, Yaohui
    Ji, Qiuhong
    WORLD NEUROSURGERY, 2016, 96 : 316 - 321
  • [29] No differences in effectiveness and safety between pipeline embolization device and stent-assisted coiling for the treatment of communicating segment internal carotid artery aneurysms
    Enriquez-Marulanda, Alejandro
    Salem, Mohamed M.
    Ascanio, Luis C.
    Maragkos, Georgios A.
    Gupta, Raghav
    Moore, Justin M.
    Thomas, Ajith J.
    Ogilvy, Christopher S.
    Alturki, Abdulrahman Y.
    NEURORADIOLOGY JOURNAL, 2019, 32 (05) : 344 - 352
  • [30] Flow alteration surgery using a radial artery graft for recurrent ruptured vertebral artery dissecting aneurysm after stent-assisted coil embolization: A case report
    Abiko, Masaru
    Hashimoto, Yukishige
    Mitsunobu, Masakazu
    Horie, Nobutaka
    NEUROCHIRURGIE, 2024, 70 (05)