Harmonic and Negative-Sequence Current Control in an Islanded Multi-Bus MV Microgrid

被引:104
作者
Hamzeh, Mohsen [1 ]
Karimi, Houshang [2 ]
Mokhtari, Hossein [1 ]
机构
[1] Sharif Univ Technol, Ctr Excellence Power Syst Management & Control, Tehran, Iran
[2] Ecole Polytech, Dept Genie Elect, Montreal, PQ H3C 3A7, Canada
关键词
Distributed generation; harmonic current; microgrid; negative-sequence; unbalanced and nonlinear loads; INVERTERS; COMPENSATION;
D O I
10.1109/TSG.2013.2263842
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a multifunctional control strategy for the autonomous operation of a multi-bus medium voltage (MV) microgrid under nonlinear and unbalanced load conditions. The main objective is to effectively compensate the harmonic currents of nonlinear loads using electronically-coupled distributed generation (DG) units. The proposed control strategy consists of a multi proportional resonant controller (MPRC) with adjustable resonance frequency and a harmonic impedance controller (HIC). The MPRC and HIC are, respectively, proposed to regulate the microgrid voltage and to share the harmonic currents of the nonlinear loads among the DG units. A conventional droop scheme is also employed to share the average powers of the loads between the DG units. Moreover, a virtual negative-sequence impedance control loop is augmented to the proposed control system to compensate the negative-sequence currents of the unbalanced loads. The proposed strategy minimizes the flow of harmonic and negative-sequence currents in the MV lines of the microgrid by local compensation of harmonic and negative-sequence currents of the feeders. The performance of the proposed control scheme is verified by using digital time-domain simulation studies in the PSCAD/EMTDC software environment.
引用
收藏
页码:167 / 176
页数:10
相关论文
共 17 条
[1]  
Akagi H, 2007, INSTANTANEOUS POWER
[2]  
[Anonymous], 2009, 1159 IEEE
[3]  
[Anonymous], 2007, PSCAD EMTDC VER 4 2
[4]  
[Anonymous], 1992, 5191992 IEEE
[5]  
[Anonymous], 1993, 141 ANSIIEEE
[6]   A new space-vector-based control method for UPS systems powering nonlinear and unbalanced loads [J].
Borup, U ;
Enjeti, PN ;
Blaabjerg, F .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2001, 37 (06) :1864-1870
[7]   Experimental Evaluation of Active Filtering in a Single-Phase High-Frequency AC Microgrid [J].
Chakraborty, Sudipta ;
Simoes, Marcelo G. .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2009, 24 (03) :673-682
[8]   CONTROL OF PARALLEL CONNECTED INVERTERS IN STANDALONE AC SUPPLY-SYSTEMS [J].
CHANDORKAR, MC ;
DIVAN, DM ;
ADAPA, R .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1993, 29 (01) :136-143
[9]   A Cooperative Imbalance Compensation Method for Distributed-Generation Interface Converters [J].
Cheng, Po-Tai ;
Chen, Chien-An ;
Lee, Tung-Lin ;
Kuo, Shen-Yuan .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2009, 45 (02) :805-815
[10]   Decentralized Parallel Operation of Inverters Sharing Unbalanced and Nonlinear Loads [J].
De, Dipankar ;
Ramanarayanan, Venkataramanan .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (12) :2995-3025