Design of an Experimental Set-Up to Study the Behavior of a Flexible Surgical Instrument Inside an Endoscope

被引:4
作者
Khatait, Jitendra P. [1 ]
Brouwer, Dannis M. [1 ,2 ]
Soemers, Herman M. J. R. [3 ]
Aarts, Ronald G. K. M. [1 ]
Herder, Just L. [1 ]
机构
[1] Univ Twente, Fac Engn Technol, NL-7500 AE Enschede, Netherlands
[2] Demcon Adv Mechatron, NL-7521 PH Enschede, Netherlands
[3] Philips Innovat Serv, NL-5656 AE Eindhoven, Netherlands
来源
JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME | 2013年 / 7卷 / 03期
关键词
experimental setup; design; evaluation; flexible wire; surgical instrument; SURGERY;
D O I
10.1115/1.4024660
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The success of flexible instruments in surgery requires high motion and force fidelity and controllability of the tip. However, the friction and the limited stiffness of such instruments limit the motion and force transmission of the instrument. In a previous study, we developed a flexible multibody model of a surgical instrument inside an endoscope in order to study the effect of the friction, bending and rotational stiffness of the instrument and clearance on the motion hysteresis and the force transmission. In this paper, we present the design and evaluation of an experimental setup for the validation of the flexible multibody model and the characterization of the instruments. A modular design was conceived based on three key functionalities: the actuation from the proximal end, the displacement measurement of the distal end, and the measurement of the interaction force. The exactly constrained actuation module achieves independent translation and rotation of the proximal end. The axial displacement and the rotation of the distal end are measured contactless via a specifically designed air bearing guided cam through laser displacement sensors. The errors in the static measurement are 15 mu m in translation and 0.15 deg in rotation. Six 1-DOF load cell modules using flexures measure the interaction forces and moments with an error of 0.8% and 2.5%, respectively. The achieved specifications allow for the measurement of the characteristic behavior of the instrument inside a curved rigid tube and the validation of the flexible multibody model.
引用
收藏
页数:12
相关论文
共 24 条
[1]   Flexible multibody modelling for exact constraint design of compliant mechanisms [J].
Aarts, R. G. K. M. ;
Meijaard, J. P. ;
Jonker, J. B. .
MULTIBODY SYSTEM DYNAMICS, 2012, 27 (01) :119-133
[2]  
[Anonymous], 2010, SIGN PROC TOOLB US G
[3]  
Blanding D.K., 1999, EXACT CONSTRAINT MAC
[4]   Robotic technology in surgery: past, present, and future [J].
Camarillo, DB ;
Krummel, TM ;
Salisbury, JK .
AMERICAN JOURNAL OF SURGERY, 2004, 188 (4A) :2S-15S
[5]   A Comprehensive Review of Single-Incision Laparoscopic Surgery (SILS) and Natural Orifice Transluminal Endoscopic Surgery (NOTES) Techniques for Cholecystectomy [J].
Chamberlain, Ronald Scott ;
Sakpal, Sujit Vijay .
JOURNAL OF GASTROINTESTINAL SURGERY, 2009, 13 (09) :1733-1740
[6]   Surgical robotics: Reviewing the past, analysing the present, imagining the future [J].
Gomes, Paula .
ROBOTICS AND COMPUTER-INTEGRATED MANUFACTURING, 2011, 27 (02) :261-266
[7]  
Honeywell Sensing and Control, 2010, MIN LOAD CELL
[8]  
HUMUSOFT, 2010, MF624 MULT I O CARD
[9]  
Khatait J. P., 2011, ASME 2011 INT MECH E, V2, P557
[10]  
Khatait J. P., 2012, ASME 2012 INT MECH E