In vivo estimation of transverse relaxation time constant (T2) of 17 human brain metabolites at 3T

被引:39
|
作者
Wyss, Patrik O. [1 ,2 ,3 ]
Bianchini, Claudio [4 ]
Scheidegger, Milan [1 ,2 ]
Giapitzakis, Ioannis A. [3 ]
Hock, Andreas [1 ,2 ]
Fuchs, Alexander [1 ,2 ]
Henning, Anke [1 ,2 ,3 ,5 ]
机构
[1] Univ Zurich, Inst Biomed Engn, Gloriastr 35, CH-8092 Zurich, Switzerland
[2] ETH, Gloriastr 35, CH-8092 Zurich, Switzerland
[3] Max Planck Inst Biol Cybernet, Tubingen, Germany
[4] Univ Bologna, Dept Biomed & Neuromotor Sci, Bologna, Italy
[5] Ernst Moritz Arndt Univ Greifswald, Inst Phys, Greifswald, Germany
基金
瑞士国家科学基金会;
关键词
T-2 relaxation time; 3T; human; in vivo; gray and white matter; T-1; correction; OUTER VOLUME SUPPRESSION; CEREBRAL METABOLITES; PROTON METABOLITES; DIFFERENT REGIONS; T2; QUANTIFICATION; GLUTAMATE; GABA; SPECTROSCOPY; GLUTATHIONE;
D O I
10.1002/mrm.27067
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThe transverse relaxation times T-2 of 17 metabolites in vivo at 3T is reported and region specific differences are addressed. MethodsAn echo-time series protocol was applied to one, two, or three volumes of interest with different fraction of white and gray matter including a total number of 106 healthy volunteers and acquiring a total number of 128 spectra. The data were fitted with the 2D fitting tool ProFit2, which included individual line shape modeling for all metabolites and allowed the T-2 calculation of 28 moieties of 17 metabolites. ResultsThe T-2 of 10 metabolites and their moieties have been reported for the first time. Region specific T-2 differences in white and gray matter enriched tissue occur in 16 of 17 metabolites examined including single resonance lines and coupled spin systems. ConclusionThe relaxation time T-2 is regions specific and has to be considered when applying tissue composition correction for internal water referencing. Magn Reson Med 80:452-461, 2018. (c) 2018 International Society for Magnetic Resonance in Medicine.
引用
收藏
页码:452 / 461
页数:10
相关论文
共 50 条
  • [41] Simultaneous measurement of total water content and myelin water fraction in brain at 3 T using a T2 relaxation based method
    Meyers, Sandra M.
    Kolind, Shannon H.
    MacKay, Alex L.
    MAGNETIC RESONANCE IMAGING, 2017, 37 : 187 - 194
  • [42] T2 relaxation time measurements in osteoarthritis
    David-Vaudey, E
    Ghosh, S
    Ries, M
    Majumdar, S
    MAGNETIC RESONANCE IMAGING, 2004, 22 (05) : 673 - 682
  • [43] T2 Relaxation Time Abnormalities in Bipolar Disorder and Schizophrenia
    Ongur, Dost
    Prescot, Andrew P.
    Jensen, J. Eric
    Rouse, Elizabeth D.
    Cohen, Bruce M.
    Renshaw, Perry F.
    Olson, David P.
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (01) : 1 - 8
  • [44] J-Difference editing (MEGA) of lactate in the human brain at 3T
    Robison, Ryan K. K.
    Haynes, Justin R. R.
    Ganji, Sandeep K. K.
    Nockowski, Charles P. P.
    Kovacs, Zoltan
    Pham, Wellington
    Morgan, Victoria L. L.
    Smith, Seth A. A.
    Thompson, Reid C. C.
    Omary, Reed A. A.
    Gore, John C. C.
    Choi, Changho
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (03) : 852 - 862
  • [45] Validation and Optimization of Adiabatic T1ρ and T2ρ for Quantitative Imaging of Articular Cartilage at 3T
    Casula, Victor
    Autio, Joonas
    Nissi, Mikko J.
    Auerbach, Edward J.
    Ellermann, Jutta
    Lammentausta, Eveliina
    Nieminen, Miika T.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (03) : 1265 - 1275
  • [46] T1rho and T2 relaxation times of the normal adult knee meniscus at 3T: analysis of zonal differences
    Takao, Shoichiro
    Nguyen, Tan B.
    Yu, Hon J.
    Hagiwara, Shigeo
    Kaneko, Yasuhito
    Nozaki, Taiki
    Iwamoto, Seiji
    Otomo, Maki
    Schwarzkopf, Ran
    Yoshioka, Hiroshi
    BMC MUSCULOSKELETAL DISORDERS, 2017, 18 : 1 - 9
  • [47] Proton T2 relaxation of cerebral metabolites during transient global ischemia in rat brain
    Fujimori, H
    Michaelis, T
    Wick, M
    Frahm, J
    MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (04) : 647 - 650
  • [48] Correlation between T2*(T2 star) relaxation time and cervical intervertebral disc degeneration An observational study
    Huang, Minghua
    Guo, Yong
    Ye, Qiong
    Chen, Lei
    Zhou, Kai
    Wang, Qingjun
    Shao, Lixin
    Shi, Qinglei
    Chen, Chun
    MEDICINE, 2016, 95 (47)
  • [49] Are mono-exponential fits to a few echoes sufficient to determine T2 relaxation for in vivo human brain?
    Whittall, KP
    MacKay, AL
    Li, DKB
    MAGNETIC RESONANCE IN MEDICINE, 1999, 41 (06) : 1255 - 1257
  • [50] Long component time constant of 23Na T*2 relaxation in healthy human brain
    Bartha, R
    Menon, RS
    MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (02) : 407 - 410