In vivo estimation of transverse relaxation time constant (T2) of 17 human brain metabolites at 3T

被引:39
|
作者
Wyss, Patrik O. [1 ,2 ,3 ]
Bianchini, Claudio [4 ]
Scheidegger, Milan [1 ,2 ]
Giapitzakis, Ioannis A. [3 ]
Hock, Andreas [1 ,2 ]
Fuchs, Alexander [1 ,2 ]
Henning, Anke [1 ,2 ,3 ,5 ]
机构
[1] Univ Zurich, Inst Biomed Engn, Gloriastr 35, CH-8092 Zurich, Switzerland
[2] ETH, Gloriastr 35, CH-8092 Zurich, Switzerland
[3] Max Planck Inst Biol Cybernet, Tubingen, Germany
[4] Univ Bologna, Dept Biomed & Neuromotor Sci, Bologna, Italy
[5] Ernst Moritz Arndt Univ Greifswald, Inst Phys, Greifswald, Germany
基金
瑞士国家科学基金会;
关键词
T-2 relaxation time; 3T; human; in vivo; gray and white matter; T-1; correction; OUTER VOLUME SUPPRESSION; CEREBRAL METABOLITES; PROTON METABOLITES; DIFFERENT REGIONS; T2; QUANTIFICATION; GLUTAMATE; GABA; SPECTROSCOPY; GLUTATHIONE;
D O I
10.1002/mrm.27067
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThe transverse relaxation times T-2 of 17 metabolites in vivo at 3T is reported and region specific differences are addressed. MethodsAn echo-time series protocol was applied to one, two, or three volumes of interest with different fraction of white and gray matter including a total number of 106 healthy volunteers and acquiring a total number of 128 spectra. The data were fitted with the 2D fitting tool ProFit2, which included individual line shape modeling for all metabolites and allowed the T-2 calculation of 28 moieties of 17 metabolites. ResultsThe T-2 of 10 metabolites and their moieties have been reported for the first time. Region specific T-2 differences in white and gray matter enriched tissue occur in 16 of 17 metabolites examined including single resonance lines and coupled spin systems. ConclusionThe relaxation time T-2 is regions specific and has to be considered when applying tissue composition correction for internal water referencing. Magn Reson Med 80:452-461, 2018. (c) 2018 International Society for Magnetic Resonance in Medicine.
引用
收藏
页码:452 / 461
页数:10
相关论文
共 50 条
  • [31] Localized 1H NMR spectroscopy in different regions of human brain in vivo at 7T: T2 relaxation times and concentrations of cerebral metabolites
    Marjanska, Malgorzata
    Auerbach, Edward J.
    Valabregue, Romain
    Van de Moortele, Pierre-Francois
    Adriany, Gregor
    Garwood, Michael
    NMR IN BIOMEDICINE, 2012, 25 (02) : 332 - 339
  • [32] Proton T2 measurement and quantification of lactate in brain tumors by MRS at 3 Tesla in vivo
    Madan, Akshay
    Ganji, Sandeep K.
    An, Zhongxu
    Choe, Kevin S.
    Pinho, Marco C.
    Bachoo, Robert M.
    Maher, Elizabeth M.
    Choi, Changho
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (06) : 2094 - 2099
  • [33] Age and sex corrected normal reference values of T1, T2 T2*and ECV in healthy subjects at 3T CMR
    Roy, Clotilde
    Slimani, Alisson
    de Meester, Christophe
    Amzulescu, Mihaela
    Pasquet, Agnes
    Vancraeynest, David
    Vanoverschelde, Jean-Louis
    Pouleur, Anne-Catherine
    Gerber, Bernhard L.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2017, 19
  • [34] Ultrashort echo time (UTE) magnetic resonance imaging of the short T2 components in white matter of the brain using a clinical 3T scanner
    Du, Jiang
    Ma, Guolin
    Li, Shihong
    Carl, Michael
    Szeverenyi, Nikolaus M.
    VandenBerg, Scott
    Corey-Bloom, Jody
    Bydder, Graeme M.
    NEUROIMAGE, 2014, 87 : 32 - 41
  • [35] Measuring water content using T2 relaxation at 3 T: Phantom validations and simulations
    Meyers, Sandra M.
    Kolind, Shannon H.
    Laule, Cornelia
    MacKay, Alex L.
    MAGNETIC RESONANCE IMAGING, 2016, 34 (03) : 246 - 251
  • [36] Three-dimensional whole-heart T2 mapping at 3T
    Ding, Haiyan
    Fernandez-de-Manuel, Laura
    Schaer, Michael
    Schuleri, Karl H.
    Halperin, Henry
    He, Le
    Zviman, M. Muz
    Beinart, Roy
    Herzka, Daniel A.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (03) : 803 - 816
  • [37] Beyond T2 and 3T: New MRI techniques for clinicians
    Knowles, Benjamin R.
    Friedrich, Florian
    Fischer, Carola
    Paech, Daniel
    Ladd, Mark E.
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2019, 18 : 87 - 97
  • [38] Whole-brain T2 mapping with radial sampling and retrospective motion correction at 3T
    Corbin, Nadege
    Trotier, Aurelien J.
    Anandra, Serge
    Kadalie, Emile
    Dallet, Laurence
    Miraux, Sylvain
    Ribot, Emeline J.
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (03) : 1026 - 1042
  • [39] T2* measurement of the knee articular cartilage in osteoarthritis at 3T
    Newbould, Rexford D.
    Miller, Sam R.
    Toms, Laurence D.
    Swann, Peter
    Tielbeek, Jeroen A. W.
    Gold, Garry E.
    Strachan, Robin K.
    Taylor, Peter C.
    Matthews, Paul M.
    Brown, Andrew P.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (06) : 1422 - 1429
  • [40] Measurement of glutathione in human brain at 3T using an improved double quantum filter in vivo
    Choi, Changho
    Zhao, Chenguang
    Dimitrov, Ivan
    Douglas, Deborah
    Coupland, Nicholas J.
    Kalra, Sanjay
    Hawesa, Halima
    Davis, Jeannie
    JOURNAL OF MAGNETIC RESONANCE, 2009, 198 (02) : 160 - 166