An assessment of proximal humerus density with reference to stemless implants

被引:11
|
作者
Reeves, Jacob M. [1 ,2 ]
Athwal, George S. [2 ,3 ]
Johnson, James A. [1 ,2 ,3 ,4 ]
机构
[1] Univ Western Ontario, Dept Mech Engn, London, ON, Canada
[2] St Josephs Hosp, Roth McFarlane Hand & Upper Limb Ctr, London, ON, Canada
[3] Univ Western Ontario, Dept Surg, London, ON, Canada
[4] Univ Western Ontario, Dept Biomed Engn, London, ON, Canada
关键词
Shoulder arthroplasty; stemless; canal sparing; osteoarthritis; bone density; proximal humerus; TOTAL SHOULDER ARTHROPLASTY; PROSTHETIC DESIGN; GLENOHUMERAL OSTEOARTHRITIS; BONE-DENSITY; HEAD; GEOMETRY; MINERALIZATION; COMPLICATIONS; ADAPTATION; OUTCOMES;
D O I
10.1016/j.jse.2017.09.019
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Shoulder arthroplasty humeral components have undergone several generational changes, with systems now offering shorter stems and stemless options. The stemless humeral implants obtain fixation in the trabecular bone of the proximal humerus through elaborate fixation features. To optimize implant design, the regional variations in bone density within the proximal humerus should be determined. As such, the purpose of this computed tomography-based study was to map the regional variations in bone density of the proximal humerus. Methods: The trabecular-canal of the proximal humerus was extracted from computed tomography scans of 98 subjects and divided into 13 slices and 5 subsections (central, anterior, posterior, medial, and lateral). The average apparent density (rho(AVG)) was then quantified in each subsection of the trabecular-canal. Results: Slice depth, subsection, and gender were all significant main effects, with additional significant interactions between slice depth, subsection, and osteoarthritic condition. The slices above the resection plane had the greatest rho(AVG), with densities decreasing down the canal. The central subsection had significantly lower rho(AVG) than the peripheral sections, and the medial subsection tended to have the highest rho(AVG) (P <.001). Furthermore, the rho(AVG) of male subjects was significantly greater than that of female subjects (P <.001). Conclusions: The apparent density of the proximal humerus' trabecular-canal is nonuniform. This has implications for the design of stemless implants, indicating that implants seeking purchase in higher density bone should take advantage of the peripheral regions of the trabecular-canal within the first 15-20 mm beneath the humeral head resection plane. Level of evidence: Anatomy Study; Imaging (C) 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
引用
收藏
页码:641 / 649
页数:9
相关论文
共 50 条
  • [31] Computational anatomy of the proximal humerus: An ex vivo high-resolution peripheral quantitative computed tomography study
    Kamer, Lukas
    Noser, Hansrudi
    Popp, Albrecht Werner
    Lenz, Mark
    Blauth, Michael
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2016, 4 : 46 - 56
  • [32] Radiographic assessment of incidental bone lesions of the proximal humerus: a prevalence study
    Kara, Mustafa
    Bayram, Serkan
    Kocazeybek, Emre
    Demirtas, Gokhan
    ACTA RADIOLOGICA, 2024, 65 (10) : 1246 - 1251
  • [33] A Novel Radiological Classification System of the Proximal Humerus
    Sangaletti, Rudy
    Abuljadail, Salahulddin
    Akkaya, Mustafa
    Zanna, Luigi
    Gehrke, Thorsten
    Citak, Mustafa
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2024, 162 (06): : 600 - 605
  • [34] Shoulder arthroplasty for acute proximal humerus fracture
    Sirveaux, F.
    Roche, O.
    Mole, D.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (06) : 683 - 694
  • [35] The influence of bone mineral density and cortical index on the complexity of fractures of the proximal humerus
    den Teuling, J. W. A. M.
    Pauwels, B. S.
    Janssen, L.
    Wyers, C. E.
    Janzing, H. M. J.
    van den Bergh, J. P. W.
    Morrenhof, J. W.
    BONE & JOINT RESEARCH, 2017, 6 (10): : 584 - 589
  • [36] Total shoulder arthroplasty for the treatment of failed hemiarthroplasty in patients with fracture of the proximal humerus
    Postacchini, Roberto
    Castagna, Alessandro
    Borroni, Mario
    Cinotti, Gianluca
    Postacchini, Franco
    Gumina, Stefano
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (11) : 1542 - 1549
  • [37] Mechanisms of Failure of Locked-Plate Fixation of the Proximal Humerus: Acoustic Emissions as a Novel Assessment Modality
    Hymes, Robert A.
    Levine, Matthew J.
    Schulman, Jeff E.
    Westbrook, Ryan D.
    Li, Jihui
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2013, 27 (07) : 392 - 398
  • [38] Hemiarthroplasty for proximal humerus fractures
    Chambers L.
    Dines J.S.
    Lorich D.G.
    Dines D.M.
    Current Reviews in Musculoskeletal Medicine, 2013, 6 (1) : 57 - 62
  • [39] Augmentation technique on the proximal humerus
    Scola, A.
    Gebhard, F.
    Roederer, G.
    UNFALLCHIRURG, 2015, 118 (09): : 749 - 754
  • [40] Complications Associated with Locking Plate of Proximal Humerus Fractures
    Venkat Kavuri
    Blake Bowden
    Neil Kumar
    Doug Cerynik
    Indian Journal of Orthopaedics, 2018, 52 : 108 - 116