Respiration-Correlated Image Guidance Is the Most Important Radiotherapy Motion Management Strategy for Most Lung Cancer Patients

被引:45
作者
Korreman, Stine [1 ,2 ,4 ]
Persson, Gitte [2 ,3 ]
Nygaard, Ditte [2 ]
Brink, Carsten [5 ,6 ]
Juhler-Nottrup, Trine [7 ]
机构
[1] Roskilde Univ, Dept Sci Syst & Models, DK-4000 Roskilde, Denmark
[2] Rigshosp, Dept Radiat Oncol, Finsen Ctr, DK-2100 Copenhagen, Denmark
[3] Univ Copenhagen, Niels Bohr Inst, DK-2100 Copenhagen, Denmark
[4] Univ Wisconsin, Sch Med & Publ Hlth, Dept Human Oncol, Madison, WI 53706 USA
[5] Odense Univ Hosp, Lab Radiat Phys, DK-5000 Odense, Denmark
[6] Univ So Denmark, Fac Hlth Sci, Odense, Denmark
[7] Herlev Hosp, Dept Oncol, Copenhagen, Denmark
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2012年 / 83卷 / 04期
关键词
4DCT; IGRT; Lung cancer; Motion management; Respiratory gating; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; TUMOR MOTION; BREAST-CANCER; TRACKING; INTRAFRACTION; VARIABILITY; MARGINS; ERRORS; SCANS; 4DCT;
D O I
10.1016/j.ijrobp.2011.09.010
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The purpose of this study was to quantify the effects of four-dimensional computed tomography (4DCT), 4D image guidance (4D-IG), and beam gating on calculated treatment field margins in a lung cancer patient population. Materials and Methods: Images were acquired from 46 lung cancer patients participating in four separate protocols at three institutions in Europe and the United States. Seven patients were imaged using fluoroscopy, and 39 patients were imaged using 4DCT. The magnitude of respiratory tumor motion was measured. The required treatment field margins were calculated using a statistical recipe (van Herk M, et al. Int J Radiat Oncol Biol Phys 2000;474:1121-1135), with magnitudes of all uncertainties, except respiratory peak-to-peak displacement, the same for all patients, taken from literature. Required margins for respiratory motion management were calculated using the residual respiratory tumor motion for each patient for various motion management strategies. Margin reductions for respiration management were calculated using 4DCT, 4D-IG, and gated beam delivery. Results: The median tumor motion magnitude was 4.4 mm for the 46 patients (range 0-29.3 mm). This value corresponded to required treatment field margins of 13.7 to 36.3 mm (median 14.4 mm). The use of 4DCT, 4D-IG, and beam gating required margins that were reduced by 0 to 13.9 mm (median 0.5 mm), 3 to 5.2 mm (median 5.1 mm), and 0 to 7 mm (median 0.2 mm), respectively, to a total of 8.5 to 12.4 mm (median 8.6 mm). Conclusion: A respiratory management strategy for lung cancer radiotherapy including planning on 4DCT scans and daily image guidance provides a potential reduction of 37% to 47% in treatment field margins. The 4D image guidance strategy was the most effective strategy for > 85% of the patients. (C) 2012 Elsevier Inc.
引用
收藏
页码:1338 / 1343
页数:6
相关论文
共 25 条
[11]   Deviations in delineated GTV caused by artefacts in 4DCT [J].
Persson, Gitte Fredberg ;
Nyaard, Ditte Eklund ;
Brink, Carsten ;
Jahn, Jonas Westberg ;
af Rosenschold, Per Munck ;
Specht, Lena ;
Korreman, Stine Sofia .
RADIOTHERAPY AND ONCOLOGY, 2010, 96 (01) :61-66
[12]   Initial clinical experience with moderate deep-inspiration breath hold using an active breathing control device in the treatment of patients with left-sided breast cancer using external beam radiation therapy [J].
Remouchamps, VM ;
Letts, N ;
Vicini, FA ;
Sharpe, MB ;
Kestin, LL ;
Chen, PY ;
Martinez, AA ;
Wong, JW .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (03) :704-715
[13]   TOWARD SUBMILLIMETER ACCURACY IN THE MANAGEMENT OF INTRAFRACTION MOTION: THE INTEGRATION OF REAL-TIME INTERNAL POSITION MONITORING AND MULTILEAF COLLIMATOR TARGET TRACKING [J].
Sawant, Amit ;
Smith, Ryan L. ;
Venkat, Raghu B. ;
Santanam, Lakshmi ;
Cho, Byungchul ;
Poulsen, Per ;
Cattell, Herbert ;
Newell, Laurence J. ;
Parikh, Parag ;
Keall, Paul J. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (02) :575-582
[14]   Dosimetric impact of motion in free-breathing and gated lung radiotherapy: A 4D Monte Carlo study of intrafraction and interfraction effects [J].
Seco, Joao ;
Sharp, Greg C. ;
Wu, Ziji ;
Gierga, David ;
Buettner, Florian ;
Paganetti, Harald .
MEDICAL PHYSICS, 2008, 35 (01) :356-366
[15]   Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy [J].
Seppenwoolde, Y ;
Shirato, H ;
Kitamura, K ;
Shimizu, S ;
van Herk, M ;
Lebesque, JV ;
Miyasaka, K .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (04) :822-834
[16]   Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor [J].
Shirato, H ;
Shimizu, S ;
Kitamura, K ;
Nishioka, T ;
Kagei, K ;
Hashimoto, S ;
Aoyama, H ;
Kunieda, T ;
Shinohara, N ;
Dosaka-Akita, H ;
Miyasaka, K .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (02) :435-442
[17]   Variability of four-dimensional computed tomography patient models [J].
Sonke, Jan-Jakob ;
Lebesque, Joos ;
Van Herk, Marcel .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (02) :590-598
[18]   FRAMELESS STEREOTACTIC BODY RADIOTHERAPY FOR LUNG CANCER USING FOUR-DIMENSIONAL CONE BEAM CT GUIDANCE [J].
Sonke, Jan-Jakob ;
Rossi, Maddalena ;
Wolthaus, Jochem ;
van Herk, Marcel ;
Damen, Eugene ;
Belderbos, Jose .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (02) :567-574
[19]   A dosimetric analysis of respiration-gated radiotherapy in patients with stage III lung cancer [J].
Underberg, Rene W. M. ;
de Koste, John R. van Soernsen ;
Lagerwaard, Frank J. ;
Vincent, Andrew ;
Slotman, Ben J. ;
Senan, Suresh .
RADIATION ONCOLOGY, 2006, 1 (1)
[20]   Use of maximum intensity projections (MIP) for target volume generation in 4DCT scans for lung cancer [J].
Underberg, RWM ;
Lagerwaard, FJ ;
Slotman, BJ ;
Cuijpers, JP ;
Senan, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (01) :253-260