Enhancement of nuclear magnetic resonance in microtesla magnetic field with prepolarization field detected with high-Tc superconducting quantum interference device

被引:46
作者
Yang, Hong-Chang [1 ]
Liao, Shu-Hsien
Horng, Herng-Er
Kuo, Shing-Ling
Chen, Hsin-Hsien
Yang, S. Y.
机构
[1] Natl Taiwan Univ, Dept Phys, Taipei 116, Taiwan
[2] Natl Taiwan Univ, Dept Phys, Taipei 106, Taiwan
[3] Natl Taiwan Normal Univ, Inst Electroopt Sci & Technol, Taipei 116, Taiwan
关键词
D O I
10.1063/1.2216904
中图分类号
O59 [应用物理学];
学科分类号
摘要
We applied prepolarization field and high-T-c superconducting quantum interference device (SQUID) detector to enhance nuclear magnetic resonance signal in a microtesla magnetic field. The minimum measuring magnetic field is 8.9 mu T at which the proton resonance frequency is 380 Hz. The specificity instrumentation and the difficulty of using a high-T-c SQUID with prepolarization field were investigated. We applied gradient field to perform one-dimensional proton imaging in a microtesla magnetic field. Additionally, low field high-T-c SQUID-based NMR systems are promising in biomagnetic research due to its use, for example, in imaging with hyperpolarized noble gas. (c) 2006 American Institute of Physics.
引用
收藏
页数:3
相关论文
共 50 条
[41]   High-field optically detected nuclear magnetic resonance in GaAs [J].
Poggio, M ;
Awschalom, DD .
APPLIED PHYSICS LETTERS, 2005, 86 (18) :1-3
[42]   High-Tc superconducting quantum interference device recordings of spontaneous brain activity: Towards high-Tc magnetoencephalography [J].
Oisjoen, F. ;
Schneiderman, J. F. ;
Figueras, G. A. ;
Chukharkin, M. L. ;
Kalabukhov, A. ;
Hedstrom, A. ;
Elam, M. ;
Winkler, D. .
APPLIED PHYSICS LETTERS, 2012, 100 (13)
[43]   A cryogen-free ultralow-field superconducting quantum interference device magnetic resonance imaging system [J].
Eom, Byeong Ho ;
Penanen, Konstantin ;
Hahn, Inseob .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (09)
[44]   Low field magnetic resonance images of polarized noble gases obtained with a dc superconducting quantum interference device [J].
Augustine, MP ;
Wong-Foy, A ;
Yarger, JL ;
Tomaselli, M ;
Pines, A ;
TonThat, DM ;
Clarke, J .
APPLIED PHYSICS LETTERS, 1998, 72 (15) :1908-1910
[45]   Low field magnetic resonance images of polarized noble gases obtained with a dc superconducting quantum interference device [J].
Univ of California, Davis, United States .
Appl Phys Lett, 15 (1908-1910)
[46]   Application of superconducting quantum interference devices to nuclear magnetic resonance [J].
Greenberg, YS .
REVIEWS OF MODERN PHYSICS, 1998, 70 (01) :175-222
[47]   Microwave absorption and high-field josephson magnetic resonance in high-Tc superconductors [J].
Belevtsov, L. V. ;
D'Yachenko, A. I. ;
Kostikov, A. A. .
MODERN PHYSICS LETTERS B, 2007, 21 (15) :903-908
[48]   High-TC rf superconducting quantum interference device readout with a cryogenic preamplifier [J].
He, D. F. ;
Tachiki, M. ;
Itozaki, H. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (06)
[49]   EFFECT OF THERMAL NOISE ON THE CHARACTERISTICS OF A HIGH-TC SUPERCONDUCTING QUANTUM INTERFERENCE DEVICE [J].
ENPUKU, K ;
SHIMOMURA, Y ;
KISU, T .
JOURNAL OF APPLIED PHYSICS, 1993, 73 (11) :7929-7934
[50]   Study of Magnetic-Field Distribution Around the High-Tc Superconducting DC Cable [J].
Ohkura, Daisuke ;
Chikumoto, Noriko ;
Zhang, Yuwei ;
Otabe, Edmund Soji .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2024, 34 (03) :1-5