The interaction of carbon monoxide to Fe(III)(salen)-PEDOT:PSS composite as a gas sensor

被引:18
作者
Arabloo, F. [1 ]
Javadpour, S. [1 ]
Memarzadeh, R. [2 ]
Panahi, F. [3 ]
Emami, M. Davazdah [1 ]
Shariat, M. H. [1 ]
机构
[1] Shiraz Univ, Dept Mat Sci & Engn, Shiraz, Iran
[2] Islamic Azad Univ, Marvdasht Branch, Dept Mat Sci & Engn, Marvdasht, Iran
[3] Shiraz Univ, Dept Chem, Coll Sci, Shiraz, Iran
关键词
Chemical sensor; Fe(III)(salen); PEDOT:PSS; Thin film; Carbon monoxide; CONDUCTING POLYMERS; PEDOT/PSS; OXYGENATION; COMPLEXES; FILM; DEPOSITION; CATALYSTS; CO;
D O I
10.1016/j.synthmet.2015.04.019
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
PEDOT:PSS/Fe(salen) composite thin films were coated on glass pieces with interdigitated Au electrodes by spin coating method for CO gas sensing application. The metal complex doped PEDOT:PSS film was experienced by some common atmospheric gases to examine its identification ability for CO gas detection. The highest response factor (Delta R/R-0 x 100) and lowest response time were gained -31.32 +/- 0.88% and 38 s, respectively. An optimum level of doping (0.1 wt.% of Fe(salen)) was established for the highest sensitivity. The results showed that the sensor response was reproducible (RD < 2%) and fast recovery (5 s) in dry atmosphere and room temperature. The Fe(salen)-doped PEDOT:PSS was well characterized by different techniques such as UV-vis and FTIR spectroscopy. In addition, the surface topography of Fe(salen) doped PEDOT:PSS film was investigated using AFIVI. The results of this study can be helpful in selecting appropriate procedure for utilizing PEDOT:PSS/Fe(salen) composite for effective gas sensing applications. (c) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:192 / 199
页数:8
相关论文
共 29 条
  • [1] [Anonymous], 1995, ACTIVE OXYGEN CHEM
  • [2] Gas sensors based on conducting polymers
    Bai, Hua
    Shi, Gaoquan
    [J]. SENSORS, 2007, 7 (03) : 267 - 307
  • [3] Solvent-Controlled Spin-Coating Method for Large-Scale Area Deposition of Two-Dimensional Silica Nanosphere Assembled Layers
    Choi, Jea-Young
    Alford, T. L.
    Honsberg, Christiana B.
    [J]. LANGMUIR, 2014, 30 (20) : 5732 - 5738
  • [4] Groenendaal BL, 2000, ADV MATER, V12, P481, DOI 10.1002/(SICI)1521-4095(200004)12:7<481::AID-ADMA481>3.0.CO
  • [5] 2-C
  • [6] Hao H., 2014, Journal of Rare Earths, V32, P23
  • [7] Composites of intrinsically conducting polymers as sensing nanomaterials
    Hatchett, David W.
    Josowicz, Mira
    [J]. CHEMICAL REVIEWS, 2008, 108 (02) : 746 - 769
  • [8] HEILAND G, 1982, SENSOR ACTUATOR, V2, P343, DOI 10.1016/0250-6874(81)80055-8
  • [9] Morpholine doped poly(3,4-ethylenedioxy)thiophene-poly(styrenesulfonate) as a low temperature and quick carbon monoxide sensor
    Javadpour, S.
    Gharavi, A.
    Feizpour, A.
    Khanehzar, A.
    Panahi, F.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2009, 142 (01) : 152 - 158
  • [10] Gas-sensing characteristics of dielectrophoretically assembled composite film of oxygen plasma-treated SWCNTs and PEDOT/PSS polymer
    Jian, Jinming
    Guo, Xishan
    Lin, Liwei
    Cai, Qiang
    Cheng, Jie
    Li, Jianping
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2013, 178 : 279 - 288