Influence of end friction confinement on impact tests of concrete material at high strain rate

被引:106
作者
Hao, Y. [1 ,2 ,3 ]
Hao, H. [1 ,2 ,3 ]
Li, Z. X. [1 ,2 ,4 ]
机构
[1] Tianjin Univ, Tianjin 300072, Peoples R China
[2] Univ Western Australia, Joint Res Ctr Protect Struct, Tianjin, Peoples R China
[3] Univ Western Australia, Sch Civil & Resource Engn, Crawley, WA 6009, Australia
[4] Tianjin Univ, Sch Civil Engn, Tianjin 300072, Peoples R China
基金
澳大利亚研究理事会;
关键词
Concrete; End friction confinement; Mesoscale model; High strain rate; SHPB; COMPRESSIVE BEHAVIOR; STRENGTH ENHANCEMENT; REINFORCED-CONCRETE; NUMERICAL-ANALYSIS; DYNAMIC STRENGTH;
D O I
10.1016/j.ijimpeng.2013.04.008
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The compressive strength of concrete material increases with the strain rate. The dynamic compressive strength of concrete material is usually obtained by conducting laboratory tests such as split Hopkinson pressure bar (SHPB) test or drop-weight test. It is commonly agreed now that the dynamic increase factor (DIF) obtained from impact test is affected by lateral inertia confinement. In addition, friction at specimen-bar interfaces also constrains the lateral deformation of the specimen under high-speed impact and thus might influence the testing results as well. However, no systematic study that devotes to investigating the influence of end friction on the dynamic compression test of concrete specimen can be found in the literature. Moreover, owing to the complication of including aggregates in concrete specimens in high-speed impact tests, and complexity of including aggregates in numerical simulation of high-speed impact tests of concrete materials, coarse aggregates are usually neglected in both the laboratory tests and numerical simulations, which may not give accurate concrete material dynamic properties. In the present study, a mesoscale concrete model with distinctive consideration of different components in a concrete specimen is developed to simulate SHPB tests and to study the influence of the confinement due to end friction between specimen and pressure bars on impact tests of dynamic concrete material properties. The commercial software AUTODYN is used to carry out the numerical simulations of SHPB tests. The friction coefficient between steel bar and concrete specimen is varied from 0.0 to 0.5 in the simulation. The results confirm that the end friction confinement does affect the testing results, and its influence depends on the L/D ratio (specimen length to diameter). This observation is also verified by experimental tests. The influences with L/D ratio and friction coefficient on stress and strain distributions and failure process of mesoscale concrete specimen under different strain rates are discussed. Based on the results from numerical simulations, an empirical formula is proposed to remove the influence of end friction confinement on dynamic strength increment of concrete material obtained in SHPB tests. (c) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:82 / 106
页数:25
相关论文
共 41 条
[1]  
[Anonymous], 1993, CEB FIP MOD COD 1990
[2]  
ANSYS Inc, 2005, CENTR DYN INT TUT AU, P11
[3]  
ANSYS Inc, 2005, THEOR MAN AUTODYN RE, P173
[4]  
Atchley B.L., 1967, ACI Journal, V64, P745
[5]   DYNAMIC STRENGTH OF POLYMER MODIFIED AND FIBER-REINFORCED CONCRETES [J].
BHARGAVA, J ;
REHNSTROM, A .
CEMENT AND CONCRETE RESEARCH, 1977, 7 (02) :199-208
[6]   COMPRESSIVE BEHAVIOR OF CONCRETE AT HIGH-STRAIN RATES [J].
BISCHOFF, PH ;
PERRY, SH .
MATERIALS AND STRUCTURES, 1991, 24 (144) :425-450
[7]  
Chen WF, 1982, PLASTICITY REINFORCE, P87
[8]   Numerical investigation of concrete subjected to compressive impact loading. Part 1: A fundamental explanation for the apparent strength gain at high loading rates [J].
Cotsovos, D. M. ;
Pavlovic, M. N. .
COMPUTERS & STRUCTURES, 2008, 86 (1-2) :145-163
[9]   THE DYNAMIC COMPRESSION TESTING OF SOLIDS BY THE METHOD OF THE SPLIT HOPKINSON PRESSURE BAR [J].
DAVIES, EDH ;
HUNTER, SC .
JOURNAL OF THE MECHANICS AND PHYSICS OF SOLIDS, 1963, 11 (03) :155-179
[10]  
Fagerlund G, 1979, IMPACT STRENGTH CONC, P4