A system for individualized prosthetic modeling of the femoral head

被引:1
作者
Liu, Bin [1 ]
Huang, Zhihuan [1 ]
Jia, Xianyong [1 ]
Yue, Zongge [2 ]
机构
[1] Dalian Univ Technol, Sch Software, Dept Digital Media Technol, Dalian 116620, Liaoning Provin, Peoples R China
[2] Dalian Univ Technol, Affiliated Hosp, Dalian 116023, Liaoning Provin, Peoples R China
基金
国家高技术研究发展计划(863计划);
关键词
femoral head; individualized modeling; rehabilitation engineering; reverse technology; ACETABULUM;
D O I
10.1002/cnm.2512
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The matching quality between the femoral head prosthesis and the acetabulum plays an important role in the operative treatment of femoral head prosthetics and femoral head replacement. To obtain the optimal model of the femoral head prosthesis for the target sufferer, an individualized modeling system is shown in this paper. It can recover the necrotic femoral heads into the satisfactory models. These models can well match with the acetabulum. This new system affords a theoretical model for the accurate operation position fixing in the orthopedic clinic. And this system also provides an innovative practical means for the individualized modeling of the artificial femoral head prosthesis. Copyright (c) 2012 John Wiley & Sons, Ltd.
引用
收藏
页码:380 / 391
页数:12
相关论文
共 19 条
[1]   An innovative CCD-based high-resolution CT system for analysis of trabecular bone tissue [J].
Baruffaldi, F. ;
Beituzzi, M. ;
Bianconi, D. ;
Brancaccio, R. ;
Cornacchia, S. ;
Lanconelli, N. ;
Mancini, L. ;
Morigi, M. P. ;
Pasini, A. ;
Perilli, E. ;
Romani, D. ;
Rossi, A. ;
Casali, E. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (05) :2584-2590
[2]   Evaluation of femoral head necrosis using a volumetric method based on MRI [J].
Bassounas, A ;
Fotiadis, DI ;
Malizos, KN .
PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 :1532-1535
[3]  
Choi KH, 1997, P ANN INT IEEE EMBS, V19, P410, DOI 10.1109/IEMBS.1997.754565
[4]  
de Luis-Garcia Rodrigo, 2006, Conf Proc IEEE Eng Med Biol Soc, V2006, P4807
[5]  
Gu Dongyun, 2003, Sheng Wu Yi Xue Gong Cheng Xue Za Zhi, V20, P618
[6]  
Hu HW, 2003, ORTHOPEDIC J CHINA, V11, P472
[7]  
Kim JS, 1997, P ANN INT IEEE EMBS, V19, P418, DOI 10.1109/IEMBS.1997.754567
[8]   Human Hip Joint Cartilage: MRI Quantitative Thickness and Volume Measurements Discriminating Acetabulum and Femoral Head [J].
Li, Wei ;
Abram, Francois ;
Beaudoin, Gilles ;
Berthiaume, Marie-Josee ;
Pelletier, Jean-Pierre ;
Martel-Pelletier, Johanne .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (12) :2731-2740
[9]  
Liu Bin, 2008, Journal of Southeast University (Natural Science Edition), V38, P58
[10]  
Mitsuishi M, 2005, 2005 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS, P834