Measurement of left ventricular mass by real-time three-dimensional echocardiography: validation against magnetic resonance and comparison with two-dimensional and M-mode measurements

被引:81
|
作者
Takeuchi, Masaaki [1 ]
Nishikage, Tomoko [2 ]
Mor-Avi, Victor [3 ]
Sugeng, Lissa [3 ]
Weinert, Lynn [3 ]
Nakai, Hironi
Salgo, Ivan S. [4 ]
Gerard, Olivier [5 ]
Lang, Roberto M. [3 ]
机构
[1] Univ Occupat & Environm Hlth, Sch Med, Dept Internal Med 2, Yahatanishi Ku, Kitakyushu, Fukuoka 8078555, Japan
[2] Tane Gen Hosp, Dept Cardiol & Internal Med, Osaka, Japan
[3] Univ Chicago, Med Ctr, Noninvas Cardiac Imaging Lab, Chicago, IL 60637 USA
[4] Philips Med Syst, Andover, MA USA
[5] Philips Med Syst Res, Paris, France
关键词
echocardiography; left ventricular mass; magnetic resonance imaging;
D O I
10.1016/j.echo.2008.07.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The recent development of 3-dimensional (3D) surface detection algorithm of the endocardial and epicardial surfaces from real-time 3D echocardiographic (RT3DE) datasets allows direct semiautomated quantification of left ventricular mass (LVM). Our aims were to (1) evaluate the accuracy of RT3DE measurements of LVM using this algorithm against cardiac magnetic resonance (CMR) reference and (2) compare RT3DE LVM with conventional M-mode, 2-dimensional (2D), and RT3DE-guided biplane measurements. Methods: A total of 205 patients were studied in 2 protocols: (1) RT3DE and CMR imaging was performed on the same day in 55 subjects; (2) in an additional 150 subjects, RT3DE, 2D, and M-mode images were acquired. In both protocols, RT3DE endocardial and epicardial surfaces were semiautomatically identified at end diastole (QLab, Philips Medical Systems, Andover, MA) to calculate LVM. CMR, 2D, and M-mode-derived LVM were obtained using standard techniques. Results: A significant correlation (r = 0.95) was noted between RT3DE and CMR-derived LVM with a small bias of -2 g. M-mode-derived LVM measurements (175 +/- 64 g) were significantly larger than RT3DE LVM (123 +/- 39 g, bias: 52 g) with moderate correlation (r = 0.76). No significant differences in LVM were noted between 2D (125 +/- 42 g) and RT3DE values (bias: 1.2 g) with good correlation (r = 0.91, P < .001). However, the best correlation was noted between RT3DE and RT3DE-guided biplane LVM values (r = 0.95, P < .001, bias: -4.6 g). Intraobserver, interobserver variability, and test-retest variability of the RT3DE measurements were 9%, 12%, and 6%, respectively. Conclusion: RT3DE imaging using the 3D surface detection algorithm allows accurate and reproducible measurements of LVM. RT3DE-guided biplane technique can be used as an accurate time-saving alternative in clinical practice.
引用
收藏
页码:1001 / 1005
页数:5
相关论文
共 50 条
  • [41] Assessment of left atrial functional parameters using a novel dedicated analysis tool for real-time three-dimensional echocardiography: validation in comparison to magnetic resonance imaging
    Buechel, Ronny R.
    Sommer, Gregor
    Leibundgut, Gregor
    Rohner, Andreas
    Riede, Florian
    Kessel-Schaefer, Arnheid
    Kaufmann, Beat A.
    Zellweger, Michael J.
    Bremerich, Jens
    Handke, Michael
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (03) : 601 - 608
  • [42] Quantitative Assessment of Left Ventricle by Real-time Three-dimensional Echocardiography
    Lin, Lung-Chun
    Liau, Chiau-Suong
    Lee, Yuan-Teh
    JOURNAL OF MEDICAL ULTRASOUND, 2007, 15 (01) : 19 - 30
  • [43] Evaluation of the left ventricle with three-dimensional echocardiography: Comparison with cardiac magnetic resonance
    Claver, E.
    Leta, R.
    Pujadas, S.
    Hidalgo, A.
    Carreras, F.
    Pons-Llado, G.
    RADIOLOGIA, 2010, 52 (06): : 534 - 540
  • [44] Can Three-Dimensional Echocardiography Replace Two-Dimensional Biplane Simpson's Method? A Comparison of Fully Automated Three-Dimensional Transthoracic Echocardiography and Cardiac Magnetic Resonance Imaging for Quantification of Left Ventricular Volume and Ejection Fraction
    Mehta, Hirsch S.
    Kabra, Ashish N.
    Mohan, Rajeev C.
    Billick, Kristen
    Sato, Karoline
    Smith, Michael R.
    Rubenson, David S.
    CIRCULATION, 2013, 128 (22)
  • [45] Value of assessment of tricuspid annulus: real-time three-dimensional echocardiography and magnetic resonance imaging
    Anwar, Ashraf M.
    Soliman, Osama I. I.
    Nemes, Attila
    van Geuns, Robert-Jan M.
    Geleijnse, Marcel L.
    ten Cate, Folkert J.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2007, 23 (06) : 701 - 705
  • [46] Real-time three-dimensional echocardiography - A novel technique to quantify global left ventricular mechanical dyssynchrony
    Kapetanakis, S
    Kearney, MT
    Siva, A
    Gall, N
    Cooklin, M
    Monaghan, MJ
    CIRCULATION, 2005, 112 (07) : 992 - 1000
  • [47] Value of assessment of tricuspid annulus: real-time three-dimensional echocardiography and magnetic resonance imaging
    Ashraf M. Anwar
    Osama I. I. Soliman
    Attila Nemes
    Robert-Jan M. van Geuns
    Marcel L. Geleijnse
    Folkert J. ten Cate
    The International Journal of Cardiovascular Imaging, 2007, 23 : 701 - 705
  • [49] Assessment of left ventricular systolic synchronicity by real-time three-dimensional echocardiography in patients with dilated cardiomyopathy
    Zeng Xin
    Shu Xian-Hong
    Pan Cui-Zhen
    Chen Rui-Zhen
    Cheng Kuan
    Liu Shi-Zhen
    Chen Hao-Zhu
    CHINESE MEDICAL JOURNAL, 2006, 119 (11) : 919 - 924
  • [50] The utility of fully automated real-time three-dimensional echocardiography in the evaluation of left ventricular diastolic function
    Nakanishi, Koki
    Fukuda, Shota
    Watanabe, Hiroyuki
    Seo, Yoshihiro
    Mahara, Keitaro
    Hyodo, Eiichi
    Otsuka, Kenichiro
    Ishizu, Tomoko
    Shimada, Kenei
    Sumiyoshi, Tetsuya
    Aonuma, Kazutaka
    Tomoike, Hitonobu
    Yoshikawa, Junichi
    JOURNAL OF CARDIOLOGY, 2015, 66 (1-2) : 50 - 56