Measurement of left ventricular mass by real-time three-dimensional echocardiography: validation against magnetic resonance and comparison with two-dimensional and M-mode measurements

被引:81
|
作者
Takeuchi, Masaaki [1 ]
Nishikage, Tomoko [2 ]
Mor-Avi, Victor [3 ]
Sugeng, Lissa [3 ]
Weinert, Lynn [3 ]
Nakai, Hironi
Salgo, Ivan S. [4 ]
Gerard, Olivier [5 ]
Lang, Roberto M. [3 ]
机构
[1] Univ Occupat & Environm Hlth, Sch Med, Dept Internal Med 2, Yahatanishi Ku, Kitakyushu, Fukuoka 8078555, Japan
[2] Tane Gen Hosp, Dept Cardiol & Internal Med, Osaka, Japan
[3] Univ Chicago, Med Ctr, Noninvas Cardiac Imaging Lab, Chicago, IL 60637 USA
[4] Philips Med Syst, Andover, MA USA
[5] Philips Med Syst Res, Paris, France
关键词
echocardiography; left ventricular mass; magnetic resonance imaging;
D O I
10.1016/j.echo.2008.07.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The recent development of 3-dimensional (3D) surface detection algorithm of the endocardial and epicardial surfaces from real-time 3D echocardiographic (RT3DE) datasets allows direct semiautomated quantification of left ventricular mass (LVM). Our aims were to (1) evaluate the accuracy of RT3DE measurements of LVM using this algorithm against cardiac magnetic resonance (CMR) reference and (2) compare RT3DE LVM with conventional M-mode, 2-dimensional (2D), and RT3DE-guided biplane measurements. Methods: A total of 205 patients were studied in 2 protocols: (1) RT3DE and CMR imaging was performed on the same day in 55 subjects; (2) in an additional 150 subjects, RT3DE, 2D, and M-mode images were acquired. In both protocols, RT3DE endocardial and epicardial surfaces were semiautomatically identified at end diastole (QLab, Philips Medical Systems, Andover, MA) to calculate LVM. CMR, 2D, and M-mode-derived LVM were obtained using standard techniques. Results: A significant correlation (r = 0.95) was noted between RT3DE and CMR-derived LVM with a small bias of -2 g. M-mode-derived LVM measurements (175 +/- 64 g) were significantly larger than RT3DE LVM (123 +/- 39 g, bias: 52 g) with moderate correlation (r = 0.76). No significant differences in LVM were noted between 2D (125 +/- 42 g) and RT3DE values (bias: 1.2 g) with good correlation (r = 0.91, P < .001). However, the best correlation was noted between RT3DE and RT3DE-guided biplane LVM values (r = 0.95, P < .001, bias: -4.6 g). Intraobserver, interobserver variability, and test-retest variability of the RT3DE measurements were 9%, 12%, and 6%, respectively. Conclusion: RT3DE imaging using the 3D surface detection algorithm allows accurate and reproducible measurements of LVM. RT3DE-guided biplane technique can be used as an accurate time-saving alternative in clinical practice.
引用
收藏
页码:1001 / 1005
页数:5
相关论文
共 50 条
  • [21] Quantitative assessment of left ventricular size and function - Side-by-side comparison of real-time three-dimensional echocardiography and computed tomography with magnetic resonance reference
    Sugeng, Lissa
    Mor-Avi, Victor
    Weinert, Lynn
    Niel, Johannes
    Ebner, Christian
    Steringer-Mascherbauer, Regina
    Schmidt, Frank
    Galuschky, Christian
    Schummers, Georg
    Lang, Roberto M.
    Nesser, Hans-Joachim
    CIRCULATION, 2006, 114 (07) : 654 - 661
  • [22] Measurements of left ventricular volumes and ejection fraction with three-dimensional echocardiography: feasibility and agreement compared to two-dimensional echocardiography
    Vidar Ruddox
    Thor Edvardsen
    Morten Bækkevar
    Jan Erik Otterstad
    The International Journal of Cardiovascular Imaging, 2014, 30 : 1325 - 1330
  • [23] Measurements of left ventricular volumes and ejection fraction with three-dimensional echocardiography: feasibility and agreement compared to two-dimensional echocardiography
    Ruddox, Vidar
    Edvardsen, Thor
    Baekkevar, Morten
    Otterstad, Jan Erik
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (07) : 1325 - 1330
  • [24] Repeatability and Agreement of Real Time Three-dimensional Echocardiography Measurements of Left Ventricular Mass and Synchrony in Young Patients
    Ojala, Tiina
    Mathur, Sujeev
    Vatanen, Anu
    Sinha, Manish D.
    Jahnukainen, Kirsi
    Simpson, John
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2015, 32 (03): : 522 - 527
  • [25] Assessment of left ventricular function in chronic alcoholics by real-time three-dimensional echocardiography
    Wang, Yuanzheng
    Shan, Guoxin
    Shen, Jiaqi
    Zhou, Qiao
    Tan, Bijun
    Liu, Yue
    Luo, Runlan
    Zhao, Shifen
    Bi, Wenjun
    Yao, Fangyi
    Li, Guangsen
    MEDICINE, 2017, 96 (05)
  • [26] Fully automatic segmentation of left ventricular myocardium in real-time three-dimensional echocardiography
    Walimbe, Vivek
    Zagrodsky, Vladimir
    Shekhar, Raj
    MEDICAL IMAGING 2006: IMAGE PROCESSING, PTS 1-3, 2006, 6144
  • [27] Validation of Left Atrial Functional Measurements Using Three-dimensional Echocardiography: Comparison With Cardiac Magnetic Resonance Imaging on Various Planes
    Yamano, Michiyo
    Yamano, Tetsuhiro
    Matsushima, Shigenori
    Matsumuro, Akiyoshi
    Iwamura, Yumi
    Nakanishi, Naohiko
    Nakamura, Takeshi
    Shiraishi, Hirokazu
    Nishimura, Tsunehiko
    Shirayama, Takeshi
    CIRCULATION, 2013, 128 (22)
  • [28] Validating real-time three-dimensional echocardiography against cardiac magnetic resonance, for the determination of ventricular mass, volume and ejection fraction: a meta-analysis
    Thilini Dissabandara
    Kelly Lin
    Mark Forwood
    Jing Sun
    Clinical Research in Cardiology, 2024, 113 : 367 - 392
  • [29] Validating real-time three-dimensional echocardiography against cardiac magnetic resonance, for the determination of ventricular mass, volume and ejection fraction: a meta-analysis
    Dissabandara, Thilini
    Lin, Kelly
    Forwood, Mark
    Sun, Jing
    CLINICAL RESEARCH IN CARDIOLOGY, 2024, 113 (03) : 367 - 392
  • [30] Tomographic three-dimensional echocardiographic determination of chamber size and systolic function in patients with left ventricular aneurysm - Comparison to magnetic resonance imaging, cineventriculography, and two-dimensional echocardiography
    Buck, T
    Hunold, P
    Wentz, KU
    Tkalec, W
    Nesser, HJ
    Erbel, R
    CIRCULATION, 1997, 96 (12) : 4286 - 4297