Measurement of left ventricular mass by real-time three-dimensional echocardiography: validation against magnetic resonance and comparison with two-dimensional and M-mode measurements

被引:81
|
作者
Takeuchi, Masaaki [1 ]
Nishikage, Tomoko [2 ]
Mor-Avi, Victor [3 ]
Sugeng, Lissa [3 ]
Weinert, Lynn [3 ]
Nakai, Hironi
Salgo, Ivan S. [4 ]
Gerard, Olivier [5 ]
Lang, Roberto M. [3 ]
机构
[1] Univ Occupat & Environm Hlth, Sch Med, Dept Internal Med 2, Yahatanishi Ku, Kitakyushu, Fukuoka 8078555, Japan
[2] Tane Gen Hosp, Dept Cardiol & Internal Med, Osaka, Japan
[3] Univ Chicago, Med Ctr, Noninvas Cardiac Imaging Lab, Chicago, IL 60637 USA
[4] Philips Med Syst, Andover, MA USA
[5] Philips Med Syst Res, Paris, France
关键词
echocardiography; left ventricular mass; magnetic resonance imaging;
D O I
10.1016/j.echo.2008.07.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The recent development of 3-dimensional (3D) surface detection algorithm of the endocardial and epicardial surfaces from real-time 3D echocardiographic (RT3DE) datasets allows direct semiautomated quantification of left ventricular mass (LVM). Our aims were to (1) evaluate the accuracy of RT3DE measurements of LVM using this algorithm against cardiac magnetic resonance (CMR) reference and (2) compare RT3DE LVM with conventional M-mode, 2-dimensional (2D), and RT3DE-guided biplane measurements. Methods: A total of 205 patients were studied in 2 protocols: (1) RT3DE and CMR imaging was performed on the same day in 55 subjects; (2) in an additional 150 subjects, RT3DE, 2D, and M-mode images were acquired. In both protocols, RT3DE endocardial and epicardial surfaces were semiautomatically identified at end diastole (QLab, Philips Medical Systems, Andover, MA) to calculate LVM. CMR, 2D, and M-mode-derived LVM were obtained using standard techniques. Results: A significant correlation (r = 0.95) was noted between RT3DE and CMR-derived LVM with a small bias of -2 g. M-mode-derived LVM measurements (175 +/- 64 g) were significantly larger than RT3DE LVM (123 +/- 39 g, bias: 52 g) with moderate correlation (r = 0.76). No significant differences in LVM were noted between 2D (125 +/- 42 g) and RT3DE values (bias: 1.2 g) with good correlation (r = 0.91, P < .001). However, the best correlation was noted between RT3DE and RT3DE-guided biplane LVM values (r = 0.95, P < .001, bias: -4.6 g). Intraobserver, interobserver variability, and test-retest variability of the RT3DE measurements were 9%, 12%, and 6%, respectively. Conclusion: RT3DE imaging using the 3D surface detection algorithm allows accurate and reproducible measurements of LVM. RT3DE-guided biplane technique can be used as an accurate time-saving alternative in clinical practice.
引用
收藏
页码:1001 / 1005
页数:5
相关论文
共 50 条
  • [1] Fast measurement of left ventricular mass with real-time three-dimensional echocardiography - Comparison with magnetic resonance imaging
    Mor-Avi, V
    Sugeng, L
    Weinert, L
    MacEneaney, P
    Caiani, EG
    Koch, R
    Salgo, IS
    Lang, RM
    CIRCULATION, 2004, 110 (13) : 1814 - 1818
  • [2] REAL-TIME THREE-DIMENSIONAL ECHOCARDIOGRAPHY FOR QUANTIFYING LEFT VENTRICULAR MASS
    Hong-wen Fei* Xin-fang Wang
    ChineseMedicalSciencesJournal, 2004, (03) : 230 - 232
  • [3] Determination of left ventricular mass by real-time three-dimensional echocardiography: In vitro validation
    Takuma, S
    Cabreriza, SE
    Sciacca, R
    Di Tullio, MR
    Spotnitz, HM
    Homma, S
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2000, 17 (07): : 665 - 674
  • [4] Genetic association of left ventricular mass assessed by M-mode and two-dimensional echocardiography
    Barve, Ruteja A.
    Gu, C. Charles
    Yang, Wei
    Chu, Jian
    Davila-Roman, Victor G.
    de las Fuentes, Lisa
    JOURNAL OF HYPERTENSION, 2016, 34 (01) : 88 - 96
  • [5] Intravascular volume dependency of left ventricular mass calculation by two-dimensional guided M-mode echocardiography
    Kilickap, Mustafa
    Turhan, Sibel
    Sayin, Tamer
    Nergizoglu, Gokhan
    Kutlay, Sim
    Duman, Neval
    Rahimov, Uzeyir
    Kumbasar, Deniz
    Akgun, Cunes
    Erol, Cetin
    CANADIAN JOURNAL OF CARDIOLOGY, 2007, 23 (03) : 219 - 222
  • [6] Calculation of Pediatric Left Ventricular Mass: Validation and Reference Values Using Real-Time Three-Dimensional Echocardiography
    Laser, Kai Thorsten
    Houben, Britta Anna
    Koerperich, Hermann
    Haas, Nikolaus Alexander
    Kelter-Kloepping, Andrea
    Barth, Peter
    Burchert, Wolfgang
    DallaPozza, Robert
    Kececioglu, Deniz
    Herberg, Ulrike
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2015, 28 (03) : 275 - 283
  • [7] Three-dimensional echocardiographic measurement of left ventricular mass: Comparison with magnetic resonance imaging and two-dimensional echocardiographic determinations in man
    Michael L. Chuang
    Raymond A. Beaudin
    Marilyn F. Riley
    Matthew G. Mooney
    Warren J. Manning
    Pamela S. Douglas
    Mark G. Hibberd
    The International Journal of Cardiac Imaging, 2000, 16 : 347 - 357
  • [8] Three-dimensional echocardiographic measurement of left ventricular mass: Comparison with magnetic resonance imaging and two-dimensional echocardiographic determinations in man
    Chuang, ML
    Beaudin, RA
    Riley, MF
    Mooney, MG
    Manning, WJ
    Douglas, PS
    Hibberd, MG
    INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 2000, 16 (05): : 347 - 357
  • [9] Three-dimensional echocardiography compared to two-dimensional echocardiography for measurement of left ventricular mass anatomic validation in an open chest canine model
    Sapin, PM
    Gopal, AS
    Clarke, GB
    Smith, MD
    King, DL
    AMERICAN JOURNAL OF HYPERTENSION, 1996, 9 (05) : 467 - 474
  • [10] Value of real time three-dimensional echocardiography in patients with hypertrophic cardiomyopathy: Comparison with two-dimensional echocardiography and magnetic resonance imaging
    Bicudo, Leticia S.
    Tsutsui, Jeane M.
    Shiozaki, Afonso
    Rochitte, Carlos E.
    Arteaga, Edmundo
    Mady, Charles
    Ramires, Jose A. F.
    Mathias, Wilson, Jr.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2008, 25 (07): : 717 - 726