The stray magnetic fields in Magnetic Resonance Current Density Imaging (MRCDI)

被引:10
作者
Goksu, Cihan [1 ]
Scheffler, Klaus [2 ,3 ]
Siebner, Hartwig R. [1 ,4 ]
Thielscher, Axel [1 ,5 ]
Hanson, Lars G. [1 ,5 ]
机构
[1] Univ Copenhagen, Danish Res Ctr Magnet Resonance, Ctr Funct & Diagnost Imaging & Res, Hosp Hvidovre, Sect 714,Kettegaard Alle 30, DK-2650 Hvidovre, Denmark
[2] Max Planck Inst Biol Cybernet, High Field Magnet Resonance Ctr, Tubingen, Germany
[3] Univ Tubingen, Dept Biomed Magnet Resonance, Tubingen, Germany
[4] Copenhagen Univ Hosp, Dept Neurol, Bispebjerg, Denmark
[5] Tech Univ Denmark, Ctr Magnet Resonance, DTU Hlth Tech, Lyngby, Denmark
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2019年 / 59卷
关键词
Magnetic resonance electric impedance tomography; Magnetic Resonance Current Density Imaging; Cable currents; Physiological noise; FLUX DENSITY; ONE-COMPONENT; CONDUCTIVITY; MREIT; SENSITIVITY;
D O I
10.1016/j.ejmp.2019.02.022
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: MR Current Density Imaging (MRCDI) involves weak current-injection into the head. The resulting magnetic field changes are measured by MRI. Stray fields pose major challenges since these can dominate the fields caused by tissue currents. We analyze the sources and influences of stray fields. Methods: First, we supply validation data for a recently introduced MRCDI method with an unprecedented noise floor of similar to 0.1 nT in vivo. Second, we assess the accuracy limit of the method and our corresponding cable current correction in phantoms ensuring high signal-to-noise ratio (SNR). Third, we simulate the influence of stray fields on current flow reconstructions for various realistic experimental set-ups. Fourth, we experimentally determine the physiological field variations. Finally, we explore the consequences of head positioning in an exemplary head coil, since off-center positioning provides space for limiting cable-induced fields. Results: The cable correction method performs well except near the cables. Unless correcting for cable currents, the reconstructed current flow is easily misestimated by up to 45% for a realistic experimental set-up. Stray fields dominating the fields caused by tissue currents can occur, e.g. due to a wire segment 20 cm away from the imaged region, or due to a slight cable misalignment of 3 degrees. The noise is increased by 40% due to physiological factors. Minor patient movements can cause field changes of similar to 40 nT. Off-centered head positioning can locally reduce SNR by e.g. 30%. Conclusions: Quantification of stray fields showed that MRCDI requires careful field correction. After cable correction, physiological noise is a limiting factor.
引用
收藏
页码:142 / 150
页数:9
相关论文
共 34 条
  • [21] Alternating steady state free precession for estimation of current-induced magnetic flux density: A feasibility study
    Lee, Hyunyeol
    Jeong, Woo Chul
    Kim, Hyung Joong
    Woo, Eung Je
    Park, Jaeseok
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (05) : 2009 - 2019
  • [22] EEG and MEG: Forward solutions for inverse methods
    Mosher, JC
    Leahy, RM
    Lewis, PS
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1999, 46 (03) : 245 - 259
  • [23] Optimization of multiply acquired magnetic flux density Bz using ICNE-Multiecho train in MREIT
    Nam, Hyun Soo
    Kwon, Oh In
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (09) : 2743 - 2759
  • [24] Conductivity and current density image reconstruction using harmonic Bz algorithm in magnetic resonance electrical impedance tomography
    Oh, SH
    Lee, BI
    Woo, EJ
    Lee, SY
    Cho, MH
    Kwon, O
    Seo, JK
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (19) : 3101 - 3116
  • [25] Determinants of the electric field during transcranial direct current stimulation
    Opitz, Alexander
    Paulus, Walter
    Will, Susanne
    Antunes, Andre
    Thielscher, Axel
    [J]. NEUROIMAGE, 2015, 109 : 140 - 150
  • [26] Analysis of recoverable current from one component of magnetic flux density in MREIT and MRCDI
    Park, Chunjae
    Lee, Byung Il
    Kwon, Oh In
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (11) : 3001 - 3013
  • [27] Sadighi M, 2014, IEEE ENG MED BIO, P1139, DOI 10.1109/EMBC.2014.6943796
  • [28] SENSITIVITY OF MAGNETIC-RESONANCE CURRENT-DENSITY IMAGING
    SCOTT, GC
    JOY, MLG
    ARMSTRONG, RL
    HENKELMAN, RM
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1992, 97 (02) : 235 - 254
  • [29] MEASUREMENT OF NONUNIFORM CURRENT-DENSITY BY MAGNETIC-RESONANCE
    SCOTT, GC
    JOY, MLG
    ARMSTRONG, RL
    HENKELMAN, RM
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) : 362 - 374
  • [30] Magnetic Resonance Electrical Impedance Tomography (MREIT)
    Seo, Jin Keun
    Woo, Eung Je
    [J]. SIAM REVIEW, 2011, 53 (01) : 40 - 68