Iterative image reconstruction techniques: Applications for cardiac CT

被引:71
作者
Renker, Matthias [1 ]
Ramachandra, Ashok [1 ]
Schoepf, U. Joseph [1 ]
Raupach, Rainer [2 ]
Apfaltrer, Paul [1 ,3 ]
Rowe, Garrett W. [1 ]
Vogt, Sebastian [2 ]
Flohr, Thomas G. [2 ]
Kerl, J. Matthias [4 ]
Bauer, Ralf W. [4 ]
Fink, Christian [3 ]
Henzler, Thomas [1 ,3 ]
机构
[1] Med Univ S Carolina, Heart & Vasc Ctr, Charleston, SC 29401 USA
[2] Siemens Healthcare, CT Div, Forchheim, Germany
[3] Univ Heidelberg, Med Fac Mannheim, Univ Med Ctr Mannheim, Dept Clin Radiol & Nucl Med, D-6800 Mannheim, Germany
[4] Goethe Univ Frankfurt, Dept Diagnost & Intervent Radiol, Frankfurt, Germany
关键词
Iterative reconstruction; Filtered back-projection; Coronary CT angiography; Image noise; Radiation dose; Cardiac CT; DOSE REDUCTION; QUALITY;
D O I
10.1016/j.jcct.2011.05.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Traditional limitations of cardiac CT are related to image noise, blooming artifacts from calcifications and stents, and radiation exposure. We evaluated whether these limitations can be ameliorated by the use of iterative reconstruction in image space (IRIS) instead of traditional filtered back projection (FBP) image reconstruction techniques. METHODS: We compared image reconstruction with the use of IRIS with traditional FBP for their effect on image quality, noise, volume of heavy coronary artery calcifications, and stems as a measure of "blooming" artifacts, and radiation dose at cardiac CT. The radiation dose comparison was performed as a matched pair analysis, whereas all other comparisons were performed within the same group of patients. RESULTS: The subjective image quality of IRIS reconstructions was rated higher than FBP reconstructions. Image noise was lower with IRIS than with FBP. The volume of stems and heavy coronary artery calcifications measured lower in IRIS reconstructed series compared with FBR Similar levels of image noise were achieved with 80/100 kVp of tube voltage with IRIS compared with 120 kVp and FBP, resulting in a 62% reduction in effective dose. CONCLUSION: Our preliminary experiences suggest that IRIS incrementally improves the CT evaluation of coronary arteries, especially in challenging scenarios. Substantial radiation reduction seems feasible without associated increases in image noise. (C) 2011 Society of Cardiovascular Computed Tomography. All rights reserved.
引用
收藏
页码:225 / 230
页数:6
相关论文
共 9 条
  • [1] Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience
    Bittencourt, Marcio Sommer
    Schmidt, Bernhard
    Seltmann, Martin
    Muschiol, Gerd
    Ropers, Dieter
    Daniel, Werner Guenther
    Achenbach, Stephan
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (07) : 1081 - 1087
  • [2] THEORY OF IMAGE RECONSTRUCTION IN COMPUTED TOMOGRAPHY
    BROOKS, RA
    DICHIRO, G
    [J]. RADIOLOGY, 1975, 117 (03) : 561 - 572
  • [3] Adaptive Iterative Reconstruction
    Bruder, H.
    Raupach, R.
    Sunnegardh, J.
    Sedlmair, M.
    Stierstorfer, K.
    Flohr, T.
    [J]. MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [4] A Prospective Evaluation of Dose Reduction and Image Quality in Chest CT Using Adaptive Statistical Iterative Reconstruction
    Leipsic, Jonathon
    Nguyen, Giang
    Brown, Jaqueline
    Sin, Don
    Mayo, John R.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (05) : 1095 - 1099
  • [5] Estimated Radiation Dose Reduction Using Adaptive Statistical Iterative Reconstruction in Coronary CT Angiography: The ERASIR Study
    Leipsic, Jonathon
    LaBounty, Troy M.
    Heilbron, Brett
    Min, James K.
    Mancini, G. B. John
    Lin, Fay Y.
    Taylor, Carolyn
    Dunning, Allison
    Earls, James P.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) : 655 - 660
  • [6] Min James K, 2009, J Cardiovasc Comput Tomogr, V3, P246, DOI 10.1016/j.jcct.2009.06.006
  • [7] Calcified plaque: Measurement of area at thin-section flat-panel CT and 64-section multidetector CT and comparison with histopathologic findings
    Sarwar, Ammar
    Rieber, Johannes
    Mooyaart, Eline A. Q.
    Seneviratne, Sujith K.
    Houser, Stuart L.
    Bamberg, Fabian
    Raffel, O. Christopher
    Gupta, Rajiv
    Kalra, Mannudeep K.
    Pien, Homer
    Lee, Hang
    Brady, Thomas J.
    Hoffmann, Udo
    [J]. RADIOLOGY, 2008, 249 (01) : 301 - 306
  • [8] A three-dimensional statistical approach to improved image quality for multislice helical CT
    Thibault, Jean-Baptiste
    Sauer, Ken D.
    Bouman, Charles A.
    Hsieh, Jiang
    [J]. MEDICAL PHYSICS, 2007, 34 (11) : 4526 - 4544
  • [9] Noise and resolution in images reconstructed with FBP and OSC algorithms for CT
    Ziegler, A.
    Koehler, Th.
    Proksa, R.
    [J]. MEDICAL PHYSICS, 2007, 34 (02) : 585 - 598