Diagnostic Accuracy of Computed Tomography Using Lower Doses of Radiation for Patients With Crohn's Disease

被引:44
作者
Craig, Orla
O'Neill, Siobhan
O'Neill, Fiona
McLaughlin, Patrick
McGarrigle, Annemarie
McWilliams, Sebastian
O'Connor, Owen
Desmond, Alan
Walsh, Elizabeth Kenny
Ryan, Max
Maher, Michael
Shanahan, Fergus [3 ]
机构
[1] Cork Univ Hosp, Dept Med, Cork, Ireland
[2] Cork Univ Hosp, Dept Radiol, Cork, Ireland
[3] Univ Coll Cork, Natl Univ Ireland, Dept Med, Alimentary Pharmabiot Ctr, Cork, Ireland
基金
爱尔兰科学基金会;
关键词
IBD; Diagnostic Imaging; Risk; Perforation; STATISTICAL ITERATIVE RECONSTRUCTION; FILTERED BACK-PROJECTION; IONIZING-RADIATION; CT ENTEROGRAPHY; ABDOMINAL CT; SMALL-BOWEL; EXPOSURE; REDUCTION; MDCT;
D O I
10.1016/j.cgh.2012.03.014
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BACKGROUND & AIMS: Magnetic resonance and ultrasonography have increasing roles in the initial diagnosis of Crohn's disease, but computed tomography (CT) with positive oral contrast agents is most frequently used to identify those with acute extramural complications. However, CT involves exposure of patients to radiation. We prospectively compared the diagnostic accuracy of low-dose CT (at a dose comparable to that used to obtain an abdominal radiograph) with conventional-dose CT in patients with active Crohn's disease. METHODS: Low and conventional dose CT of the abdomen and pelvis were acquired from 50 patients with Crohn's disease, referred from an inflammatory bowel disease service (20 male; median age, 34 years). Acute complications of Crohn's disease were suspected. Iterative reconstruction was performed on all CT datasets to facilitate dose reduction. Three radiologists reviewed the low-dose CT images before the conventional-dose CT images. RESULTS: The median effective dose (interquartile range) of radiation for the low-dose CT was reduced by 72% from that of conventional CT: from 3.5 mSv (3-5.08 mSv) to 0.98 mSv (0.77-1.42 mSv) (P < .001). As expected, the quality indexes of the low-dose images were inferior to those of the conventional-dose images, but no clinically significant diagnostic findings were missed with low-dose imaging. Follow-up CT examinations were recommended for 5 patients; 1 had a cervical tumor, 1 had a pancreatic lesion, and 3 had intra-abdominal abscess. In each case, the image obtained by low-dose CT was considered sufficient for diagnosis. CONCLUSIONS: Although low-dose CT images are of lower quality than images obtained with conventional doses of radiation, no clinically significant diagnostic findings were missed from low-dose CT images of patients with Crohn's disease. The low-dose CT was obtained at a median effective dose equivalent to 1.4 abdominal radiographs.
引用
收藏
页码:886 / 892
页数:7
相关论文
共 26 条
[1]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[2]   Estimating radiation doses from multidetector CT using Monte Carlo simulations: effects of different size voxelized patient models on magnitudes of organ and effective dose [J].
DeMarco, J. J. ;
Cagnon, C. H. ;
Cody, D. D. ;
Stevens, D. M. ;
McCollough, C. H. ;
Zankl, M. ;
Angel, E. ;
McNitt-Gray, M. F. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (09) :2583-2597
[3]   Crohn's disease: factors associated with exposure to high levels of diagnostic radiation [J].
Desmond, A. N. ;
O'Regan, K. ;
Curran, C. ;
McWilliams, S. ;
Fitzgerald, T. ;
Maher, M. M. ;
Shanahan, F. .
GUT, 2008, 57 (11) :1524-1529
[4]  
Desmond AN, 2012, CAN ASS RADIOL J
[5]   Significance of Abdominal Ultrasound in Inflammatory Bowel Disease [J].
Dietrich, C. F. .
DIGESTIVE DISEASES, 2009, 27 (04) :482-493
[6]   Reducing the Radiation Dose for CT Colonography Using Adaptive Statistical Iterative Reconstruction: A Pilot Study [J].
Flicek, Kristina T. ;
Hara, Amy K. ;
Silva, Alvin C. ;
Wu, Qing ;
Peter, Mary B. ;
Johnson, C. Daniel .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (01) :126-131
[7]   Iterative Reconstruction Technique for Reducing Body Radiation Dose at CT: Feasibility Study [J].
Hara, Amy K. ;
Paden, Robert G. ;
Silva, Alvin C. ;
Kujak, Jennifer L. ;
Lawder, Holly J. ;
Pavlicek, William .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (03) :764-771
[8]  
HARVEY RF, 1980, LANCET, V1, P514
[9]   Converting dose-length product to effective dose at CT [J].
Huda, Walter ;
Ogden, Kent M. ;
Khorasani, Mohammad R. .
RADIOLOGY, 2008, 248 (03) :995-1003
[10]   Radiation doses from small-bowel follow-through and abdominopelvic MDCT in Crohn's disease [J].
Jaffe, Tracy A. ;
Gaca, Ana Maria ;
Delaney, Susan ;
Yoshizumi, Terry T. ;
Toncheva, Greta ;
Nguyen, Giao ;
Frush, Donald P. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (05) :1015-1022