Electrical Reconnection After Pulmonary Vein Isolation Is Contingent on Contact Force During Initial Treatment Results From the EFFICAS I Study

被引:341
|
作者
Neuzil, Petr [1 ]
Reddy, Vivek Y. [2 ]
Kautzner, Josef [3 ]
Petru, Jan [1 ]
Wichterle, Dan [3 ]
Shah, Dipen [4 ]
Lambert, Hendrik [5 ]
Yulzari, Aude [5 ]
Wissner, Erik [6 ]
Kuck, Karl-Heinz [6 ]
机构
[1] Na Homolce Hosp, Dept Cardiol, Prague 15630 5, Czech Republic
[2] Mt Sinai Sch Med, Cardiac Arrhythmia Serv, New York, NY USA
[3] Inst Clin & Expt Med IKEM, Dept Cardiol, Prague, Czech Republic
[4] Univ Hosp Geneva, Geneva, Switzerland
[5] Endosense SA, Geneva, Switzerland
[6] Asklepios Klin St Georg, Abt Kardiol, Hamburg, Germany
关键词
atrial fibrillation; catheter ablation; contact force; gaps; RADIOFREQUENCY CATHETER ABLATION; PAROXYSMAL ATRIAL-FIBRILLATION; LESION SIZE; FOLLOW-UP; TOCCATA; SITES; MODEL; TRIAL;
D O I
10.1161/CIRCEP.113.000374
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Pulmonary vein isolation is the most prevalent approach for catheter ablation of paroxysmal atrial fibrillation. Long-term success of the procedure is diminished by arrhythmia recurrences occurring predominantly because of reconnections in previously isolated pulmonary veins. The aim of the EFFICAS I multicenter study was to demonstrate the correlation between contact force (CF) parameters during initial procedure and the incidence of isolation gaps (gap) at 3-month follow-up. Method and Results-A radiofrequency ablation catheter with integrated CF sensor (TactiCath, Endosense, Geneva, Switzerland) was used to perform pulmonary vein isolation in 46 patients with paroxysmal atrial fibrillation. During the ablation procedure, the operator was blinded to CF information. At follow-up, an interventional diagnostic procedure was performed to assess gap location as correlated to index procedure ablation parameters. At follow-up, 65% (26/40) of patients showed 1 gaps. Ablations with minimum Force-Time Integral (FTI) <400 gs showed increased likelihood for reconnection (P<0.001). Reconnection correlated strongly with minimum CF (P<0.0001) and minimum FTI (P=0.0007) at the site of gap. Gap occurrence showed a strong trend with lower average CF and average FTI. CF and FTI are generally higher on the right side, although the left anterior segment presents a unique challenge to achieve stable position with good CF. Conclusions-Minimum CF and minimum FTI values are strong predictors of gap formation. Optimal CF parameter recommendations are a target CF of 20 g and a minimum FTI of 400 gs for each new lesion.
引用
收藏
页码:327 / 333
页数:7
相关论文
共 50 条
  • [21] Comparison of contact force-guided procedure with non-contact force-guided procedure during left atrial mapping and pulmonary vein isolation: impact of contact force on recurrence of atrial fibrillation
    Makimoto, Hisaki
    Heeger, Christian-H
    Lin, Tina
    Rillig, Andreas
    Metzner, Andreas
    Wissner, Erik
    Mathew, Shibu
    Deiss, Sebastian
    Rausch, Peter
    Lemes, Christine
    Kuck, Karl-Heinz
    Ouyang, Feifan
    Tilz, Roland Richard
    CLINICAL RESEARCH IN CARDIOLOGY, 2015, 104 (10) : 861 - 870
  • [22] Contact force facilitates the achievement of an unexcitable ablation line during pulmonary vein isolation
    Benjamin Schaeffer
    Stephan Willems
    Christian Meyer
    Jakob Lüker
    Ruken Ö. Akbulak
    Julia Moser
    Mario Jularic
    Christian Eickholt
    Jana M. Schwarzl
    Melanie Gunawardene
    Pawel Kuklik
    Arian Sultan
    Boris A. Hoffmann
    Daniel Steven
    Clinical Research in Cardiology, 2018, 107 : 632 - 641
  • [23] Pace-capture-guided ablation after contact-force-guided pulmonary vein isolation: results of the randomized controlled DRAGON trial
    Masuda, Masaharu
    Fujita, Masashi
    Iida, Osamu
    Okamoto, Shin
    Ishihara, Takayuki
    Nanto, Kiyonori
    Kanda, Takashi
    Sunaga, Akihiro
    Tsujimura, Takuya
    Matsuda, Yasuhiro
    Ohashi, Takuya
    Uematsu, Masaaki
    EUROPACE, 2018, 20 (09): : 1451 - 1458
  • [24] Predictors of chronic pulmonary vein reconnections after contact force-guided ablation: importance of completing electrical isolation with circumferential lines and creating sufficient ablation lesion densities
    Nakamura, Kohki
    Naito, Shigeto
    Sasaki, Takehito
    Minami, Kentaro
    Take, Yutaka
    Shimizu, Satoru
    Yamaguchi, Yoshiaki
    Yano, Toshiaki
    Senga, Michiharu
    Yamashita, Eiji
    Sugai, Yoshinao
    Kumagai, Koji
    Funabashi, Nobusada
    Oshima, Shigeru
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2016, 47 (03) : 321 - 331
  • [25] Superior efficacy of pulmonary vein isolation with online contact force measurement persists after the learning period: a prospective case control study
    Michael Wolf
    Johan B. Saenen
    Wim Bories
    Hielko P. Miljoen
    Sara Nullens
    Christiaan J. Vrints
    Andrea Sarkozy
    Journal of Interventional Cardiac Electrophysiology, 2015, 43 : 287 - 296
  • [26] Impact of Contact Force Monitoring in Acute Pulmonary Vein Isolation Using an Anatomic Approach. A Randomized Study
    Pedrote, Alonso
    Arana-Rueda, Eduardo
    Arce-Leon, Alvaro
    Acosta, Juan
    Gomez-Pulido, Federico
    Luis Martos-Maine, Jose
    Frutos-Lopez, Manuel
    Sanchez-Brotons, Juan
    Garcia-Riesco, Lorena
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2016, 39 (04): : 361 - 369
  • [27] Low contact force and force-time integral predict early recovery and dormant conduction revealed by adenosine after pulmonary vein isolation
    de Waroux, Jean-Benoit le Polain
    Weerasooriya, Rukshen
    Anvardeen, Kalilur
    Barbraud, Cynthia
    Marchandise, Sebastien
    De Meester, Christophe
    Goesaert, Cedric
    Reis, Ivone
    Scavee, Christophe
    EUROPACE, 2015, 17 (06): : 877 - 883
  • [28] Pulmonary vein isolation using "contact force" ablation: The effect on dormant conduction and long-term freedom from recurrent atrial fibrillation-A prospective study
    Andrade, Jason G.
    Monir, George
    Pollak, Scott J.
    Khairy, Paul
    Dubuc, Marc
    Roy, Denis
    Talajic, Mario
    Deyell, Marc
    Rivard, Lena
    Thibault, Bernard
    Guerra, Peter G.
    Nattel, Stanley
    Macle, Laurent
    HEART RHYTHM, 2014, 11 (11) : 1919 - 1924
  • [29] Spatial distribution of electrical reconnection after pulmonary vein isolation in patients with recurrent paroxysmal atrial fibrillation
    L. M. Rademakers
    I. Romero
    T. A. Simmers
    P. H. van der Voort
    A M. Meijer
    L. R. Dekker
    Netherlands Heart Journal, 2016, 24 : 481 - 487
  • [30] Impact of Direct Contact Force Measurement on Electrical Reconnections after Circumferential Pulmonary Vein Isolation for Atrial Fibrillation Using a Contact Force-Sensing Catheter
    Nakamura, Kohki
    Naito, Shigeto
    Sasaki, Takehito
    Minami, Kentaro
    Nakano, Masahiro
    Kumagai, Koji
    Funabashi, Nobusada
    Kobayashi, Yoshio
    Oshima, Shigeru
    CIRCULATION, 2014, 130