Electrical Reconnection After Pulmonary Vein Isolation Is Contingent on Contact Force During Initial Treatment Results From the EFFICAS I Study

被引:341
|
作者
Neuzil, Petr [1 ]
Reddy, Vivek Y. [2 ]
Kautzner, Josef [3 ]
Petru, Jan [1 ]
Wichterle, Dan [3 ]
Shah, Dipen [4 ]
Lambert, Hendrik [5 ]
Yulzari, Aude [5 ]
Wissner, Erik [6 ]
Kuck, Karl-Heinz [6 ]
机构
[1] Na Homolce Hosp, Dept Cardiol, Prague 15630 5, Czech Republic
[2] Mt Sinai Sch Med, Cardiac Arrhythmia Serv, New York, NY USA
[3] Inst Clin & Expt Med IKEM, Dept Cardiol, Prague, Czech Republic
[4] Univ Hosp Geneva, Geneva, Switzerland
[5] Endosense SA, Geneva, Switzerland
[6] Asklepios Klin St Georg, Abt Kardiol, Hamburg, Germany
关键词
atrial fibrillation; catheter ablation; contact force; gaps; RADIOFREQUENCY CATHETER ABLATION; PAROXYSMAL ATRIAL-FIBRILLATION; LESION SIZE; FOLLOW-UP; TOCCATA; SITES; MODEL; TRIAL;
D O I
10.1161/CIRCEP.113.000374
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Pulmonary vein isolation is the most prevalent approach for catheter ablation of paroxysmal atrial fibrillation. Long-term success of the procedure is diminished by arrhythmia recurrences occurring predominantly because of reconnections in previously isolated pulmonary veins. The aim of the EFFICAS I multicenter study was to demonstrate the correlation between contact force (CF) parameters during initial procedure and the incidence of isolation gaps (gap) at 3-month follow-up. Method and Results-A radiofrequency ablation catheter with integrated CF sensor (TactiCath, Endosense, Geneva, Switzerland) was used to perform pulmonary vein isolation in 46 patients with paroxysmal atrial fibrillation. During the ablation procedure, the operator was blinded to CF information. At follow-up, an interventional diagnostic procedure was performed to assess gap location as correlated to index procedure ablation parameters. At follow-up, 65% (26/40) of patients showed 1 gaps. Ablations with minimum Force-Time Integral (FTI) <400 gs showed increased likelihood for reconnection (P<0.001). Reconnection correlated strongly with minimum CF (P<0.0001) and minimum FTI (P=0.0007) at the site of gap. Gap occurrence showed a strong trend with lower average CF and average FTI. CF and FTI are generally higher on the right side, although the left anterior segment presents a unique challenge to achieve stable position with good CF. Conclusions-Minimum CF and minimum FTI values are strong predictors of gap formation. Optimal CF parameter recommendations are a target CF of 20 g and a minimum FTI of 400 gs for each new lesion.
引用
收藏
页码:327 / 333
页数:7
相关论文
共 50 条
  • [1] Recurrence after pulmonary vein isolation is associated with low contact force
    Tofig, Bawer Jalal
    Lukac, Peter
    Borregaard, Rune
    Nielsen, Jan Moller
    Jensen, Henrik Kjaerulf
    Gerdes, Christian
    Kristensen, Jens
    Nielsen, Jens Cosedis
    Kristiansen, Steen Buus
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2018, 52 (01) : 28 - 33
  • [2] Three-year outcomes and reconnection patterns after initial contact force guided pulmonary vein isolation for paroxysmal atrial fibrillation
    Nair, Girish M.
    Yeo, Colin
    MacDonald, Zachary
    Ainslie, Mark P.
    Alqarawi, Wael A.
    Nery, Pablo B.
    Redpath, Calum J.
    Sadek, Mouhannad
    Spence, Stewart
    Green, Martin S.
    Birnie, David H.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (09) : 984 - 993
  • [3] EFFICAS II: optimization of catheter contact force improves outcome of pulmonary vein isolation for paroxysmal atrial fibrillation
    Kautzner, Josef
    Neuzil, Petr
    Lambert, Hendrik
    Peichl, Petr
    Petru, Jan
    Cihak, Robert
    Skoda, Jan
    Wichterle, Dan
    Wissner, Erik
    Yulzari, Aude
    Kuck, Karl-Heinz
    EUROPACE, 2015, 17 (08): : 1229 - 1235
  • [4] Regional Difference of Optimal Contact Force to Prevent Acute Pulmonary Vein Reconnection During Radiofrequency Catheter Ablation for Atrial Fibrillation
    Sotomi, Yohei
    Kikkawa, Takayuki
    Inoue, Koichi
    Tanaka, Koji
    Toyoshima, Yuko
    Oka, Takafumi
    Tanaka, Nobuaki
    Nozato, Yoichi
    Orihara, Yoshiyuki
    Iwakura, Katsuomi
    Sakata, Yasushi
    Fujii, Kenshi
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (09) : 941 - 947
  • [5] Reablated Sites of Acute Reconnection After Pulmonary Vein Isolation Do Not Predict Sites of Late Reconnection at Repeat Electrophysiology Study
    Das, Moloy
    Wynn, Gareth J.
    Morgan, Maureen
    Ronayne, Christina
    Waktare, Johan E. P.
    Todd, Derick M.
    Hall, Mark C. S.
    Snowdon, Richard L.
    Modi, Simon
    Gupta, Dhiraj
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (04) : 381 - 389
  • [6] Arrhythmia-free survival and pulmonary vein reconnection patterns after second-generation cryoballoon and contact-force radiofrequency pulmonary vein isolation
    Buist, Thomas J.
    Adiyaman, Ahmet
    Smit, Jaap Jan J.
    Misier, Anand R. Ramdat
    Elvan, Arif
    CLINICAL RESEARCH IN CARDIOLOGY, 2018, 107 (06) : 498 - 506
  • [7] Operator-blinded contact force monitoring during pulmonary vein isolation using conventional and steerable sheaths
    Kimura, Takehiro
    Takatsuki, Seiji
    Oishi, Ako
    Negishi, Masachika
    Kashimura, Shin
    Katsumata, Yoshinori
    Nishiyama, Takahiko
    Nishiyama, Nobuhiro
    Tanimoto, Yoko
    Aizawa, Yoshiyasu
    Fukuda, Keiichi
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 177 (03) : 970 - 976
  • [8] Determinants of Acute and Late Pulmonary Vein Reconnection in Contact Force-Guided Pulmonary Vein Isolation Identifying the Weakest Link in the Ablation Chain
    El Haddad, Milad
    Taghji, Philippe
    Phlips, Thomas
    Wolf, Michael
    Demolder, Anthony
    Choudhury, Rajin
    Knecht, Sebastien
    Vandekerckhove, Yves
    Tavernier, Rene
    Nakagawa, Hiroshi
    Duytschaever, Mattias
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2017, 10 (04)
  • [9] Real-Time Contact Force Sensing for Pulmonary Vein Isolation in the Setting of Paroxysmal Atrial Fibrillation: Procedural and 1-Year Results
    Marijon, Eloi
    Fazaa, Samia
    Narayanan, Kumar
    Guy-Moyat, Benoit
    Bouzeman, Abdeslam
    Providencia, Rui
    Treguer, Frederic
    Combes, Nicolas
    Bortone, Agustin
    Boveda, Serge
    Combes, Stephane
    Albenque, Jean-paul
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (02) : 130 - 137
  • [10] Mechanisms of Pulmonary Vein Reconnection After Radiofrequency Ablation of Atrial Fibrillation: The Deterministic Role of Contact Force and Interlesion Distance
    Park, Chan-Il
    Lehrmann, Heiko
    Keyl, Cornelius
    Weber, Reinhold
    Schiebeling, Jochen
    Allgeier, Juergen
    Schurr, Patrick
    Shah, Ashok
    Neumann, Franz-Josef
    Arentz, Thomas
    Jadidi, Amir S.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (07) : 701 - 708