Evaluation of the Hot Air Recirculation Effect and Relevant Empirical Formulae Applicability for Mechanical Draft Wet Cooling Towers

被引:3
作者
Dong, Haotian [1 ]
Wan, Dawei [2 ,3 ]
Liu, Minghua [2 ]
Chen, Tiefeng [4 ]
Gao, Shasha [5 ]
Zhao, Yuanbin [1 ]
机构
[1] Shandong Univ, Sch Energy & Power Engn, Jinan 250061, Peoples R China
[2] Shanghai Elect Power Stn Engn Co Ltd, Shanghai 200000, Peoples R China
[3] Shanghai Environm Protect Complete Engn Co Ltd, Shanghai 200070, Peoples R China
[4] Guodian Zheneng Ningdong Power Generat Co Ltd, Yinchuan 750408, Ningxia, Peoples R China
[5] Jinan Lanchen Energy Technol Corp Ltd, Jinan 250100, Peoples R China
基金
中国国家自然科学基金;
关键词
mechanical draft wet cooling towers; hot air recirculation rate; Cooling Technology Institute; evaluation coefficient; ambient wind; COOLED CONDENSERS; WINDBREAK WALLS; CFD SIMULATION; PERFORMANCE; WIND; CROSSWIND; EFFICIENCY; SYSTEM; MODEL;
D O I
10.3390/en13133347
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Due to the hot air recirculation, the inlet air enthalpy h1 of mechanical draft wet cooling towers (MCTs) was usually greater than the ambient air enthalpy ha. To realize the cooling performance and accurate design of MCTs, this paper clarified the feasibility of the inlet air enthalpy empirical formula presented by the Cooling Technology Institute (CTI) of the USA. A three-dimensional (3D) numerical model was established for a representative power plant, with full consideration of MCTs and adjacent main workshops, which were validated by design data and published test results. By numerical simulation, the influence of different wind directions and wind speeds on hot air recirculation (HAR) and the influence of HAR on the cooling performance of the MCTs were qualitatively studied based on the concept of hot air recirculation rate (HRR), and the correction value of HRR was compared with the calculated value of the CTI standard. The evaluation coefficient eta (h), representing the ratio of the corrected value to the calculated value was introduced to evaluate the applicability of the CTI formula. It was found that HAR was more sensitive to ambient crosswind, and an increase in HRR would deteriorate the tower cooling performance. When the crosswind speed increased from 0 to 15 m/s, eta (h), changed from 2.42 to 80.18, and the calculation error increased accordingly. It can be concluded that the CTI empirical HRR formula should be corrected when there are large buildings around the MCTs, especially under high-speed ambient crosswind conditions.
引用
收藏
页数:19
相关论文
共 39 条
[1]   CFD simulation of wet cooling towers [J].
Al-Waked, R ;
Behnia, M .
APPLIED THERMAL ENGINEERING, 2006, 26 (04) :382-395
[2]   The effect of windbreak walls on the thermal performance of natural draft dry cooling towers [J].
Al-Waked, R ;
Behnia, M .
HEAT TRANSFER ENGINEERING, 2005, 26 (08) :50-62
[3]   The performance of natural draft dry cooling towers under crosswind: CFD study [J].
Al-Waked, R ;
Behnia, M .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2004, 28 (02) :147-161
[4]   Crosswinds effect on the performance of natural draft wet cooling towers [J].
Al-Waked, Rafat .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2010, 49 (01) :218-224
[5]  
[Anonymous], 1988, GBJ10287
[6]  
[Anonymous], COOLING TOWER COOLIN
[7]  
ASHRAE, 2000, the 4th HVAC System and equipment of ASHRAE handbook
[8]   A NUMERICAL-MODEL OF COOLING-TOWER PLUME RECIRCULATION [J].
BECKER, BR ;
STEWART, WE ;
WALTER, TM ;
BECKER, CS .
MATHEMATICAL AND COMPUTER MODELLING, 1989, 12 (07) :799-819
[9]   A study on the effects of wind on the air intake flow rate of a cooling tower .2. Wind wall study [J].
Bender, TJ ;
Bergstrom, DJ ;
Rezkallah, KS .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1996, 64 (01) :61-72
[10]   Modelling atmospheric effects on performance and plume dispersal from natural draft wet cooling towers [J].
Chahine, A. ;
Matharan, P. ;
Wendum, D. ;
Musson-Genon, L. ;
Bresson, R. ;
Carissimo, B. .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2015, 136 :151-164