Computer assisted optimization of liquid chromatographic separations of small molecules using mixed-mode stationary phases

被引:19
作者
Ordonez, Edgar Y. [1 ]
Benito Quintana, Jose [1 ]
Rodil, Rosario [1 ]
Cela, Rafael [1 ]
机构
[1] Univ Santiago de Compostela, Inst Res & Food Anal, Dept Analyt Chem & Food Sci, Santiago De Compostela, Spain
关键词
Computer assisted methods development; Mixed-mode columns; Optimization; Simulation; Liquid chromatography; RESTRICTED MULTIPARAMETER APPROACH; REVERSED-PHASE; GRADIENT ELUTION; MASS-SPECTROMETRY; RETENTION PREDICTION; PROTEIN ADSORPTION; SIMPLEX ALGORITHM; HUMAN URINE; ACID; COLUMN;
D O I
10.1016/j.chroma.2012.03.055
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Mixed-mode stationary phases are gaining adepts in liquid chromatography (LC) as more and more applications are published and new commercial columns appear in the market ought to their ability to retain and separate analytes with multiple functionalities. The increased number of adjustable variables gives these columns an enhanced value for the chromatographer, but, on the other hand, it complicates the process of developing satisfactory separations when complex samples must be analyzed. Thus, the availability of computer assisted methods development (CAMD) tools is highly desirable in this field. Therefore, the first specific tool for the CAMD of LC separations in mixed-mode columns is presented. The tool consists in two processes. The first one develops a retention model for peaks in a predefined experimental domain of pH and buffer concentration. In this domain, the retention as a function of the proportion of organic modifier is modeled using a two-stage re-calibration process departing from isocratic retention data and then, from gradient elutions. With this two-stage approach, reliability is gained. In the second process, the model is finally interpolated and used for the unattended optimization of the different possible elution modes available in these columns. This optimization process is driven by an evolutionary algorithm. The development and application of this new chemometrics tool is demonstrated by the optimization of a mixture of neutral and ionizable compounds. Hence, several different types of gradients were generated, showing a good agreement between simulated and experimental data, with retention time errors lower than 5% in most cases. On the other hand, classical CAMD tools, such as design of experiments, were unable to efficiently deal with mixed-mode optimizations, rendering errors above 30% for several compounds. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:91 / 104
页数:14
相关论文
共 39 条
[1]   Retention mechanism of peptides on a stationary phase embedded with a quaternary ammonium group: A liquid chromatography study [J].
Abbood, A. ;
Smadja, C. ;
Herrenknecht, C. ;
Alahmad, Y. ;
Tchapla, A. ;
Taverna, M. .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (15) :3244-3251
[2]  
[Anonymous], SOFTW PRED RET TIM H
[3]  
[Anonymous], S MATR FUS AE FUS LC
[4]  
[Anonymous], GENETIC ALGORITHMS D
[5]   UNATTENDED OPTIMIZATION OF REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATIONS USING THE MODIFIED SIMPLEX ALGORITHM [J].
BERRIDGE, JC .
JOURNAL OF CHROMATOGRAPHY, 1982, 244 (01) :1-14
[6]   Determination of chlorpyrifos metabolites in human urine by reversed-phase/weak anion exchange liquid chromatography-electrospray ionisation-tandem mass spectrometry [J].
Bicker, W ;
Lämmerhofer, M ;
Lindner, W .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 822 (1-2) :160-169
[7]   NUCLEIC-ACID RESOLUTION BY MIXED-MODE CHROMATOGRAPHY [J].
BISCHOFF, R ;
MCLAUGHLIN, LW .
JOURNAL OF CHROMATOGRAPHY, 1984, 296 (JUL) :329-337
[8]   THE PREOPT PACKAGE FOR PRE-OPTIMIZATION OF GRADIENT ELUTIONS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CELA, R ;
BARROSO, CG ;
VISERAS, C ;
PEREZBUSTAMANTE, JA .
ANALYTICA CHIMICA ACTA, 1986, 191 :283-297
[9]  
Cela R, 1999, QUIM ANAL, V18, P29
[10]  
Cela R, 1987, INTELL INSTR COM SEP, P231