Thermal changes during implant site preparation with a digital surgical guide and slot design drill: an ex vivo study using a bovine rib model

被引:8
作者
Choi, Yoon-Sil [1 ]
Oh, Jae-Woon [1 ]
Lee, Young [2 ]
Lee, Dong-Woon [1 ,3 ,4 ]
机构
[1] Vet Hlth Serv Med Ctr, Dept Periodontol, Seoul, South Korea
[2] Vet Hlth Serv Med Ctr, Vet Med Res Inst, Seoul, South Korea
[3] Wonkwang Univ, Dent Hosp, Dept Periodontol, Coll Dent, Iksan, South Korea
[4] Wonkwang Univ, Dent Hosp, Dept Periodontol, Coll Dent, 895 Muwang ro, Iksan 54538, South Korea
关键词
Cortical bone; Dental implants; In vitro techniques; Osteonecrosis; Thermometers; BONE-DENSITY; IRRIGATION TEMPERATURE; HEAT-GENERATION; PLACEMENT; TEMPLATE;
D O I
10.5051/jpis.2106040302
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: In this study, we aimed to evaluate the degree of heat generation when a novel drill design with an irrigation slot was used with metal sleeve-free (MF) and metal sleeve -incorporated (MI) surgical guides in an environment similar to that of the actual oral cavity.Methods: A typodont with a missing mandibular right first molar and 21 bovine rib blocks were used. Three-dimensional-printed MF and MI surgical guides, designed for the placement of internal tapered implant fixtures, were used with slot and non-slot drills. The following groups were compared: group 1, MI surgical guide with slot drill; group 2, MI surgical guide with a non-slot drill; and group 3, MF surgical guide with a slot drill. A constant-temperature water bath at 36 degrees C was used. The drilling was performed in 6 stages, and the initial, highest, and lowest temperatures of the cortical bone were measured at each stage using a non-contact infrared thermometer.Results: There were no temperature increases above the initial temperature in any drilling procedure. The only significant difference between the non-slot and slot groups was observed with the use of the first drill in the MI group, with a higher temperature in the non-slot group (P=0.012). When the heat generation during the first and the second drilling was compared in the non-slot group, the heat generation during the first drilling was significantly higher (P<0.001), and there was no significant difference in heat generation between the drills in the slot group.Conclusions: Within the limitations of this study, implant-site preparation with the surgical guide showed no critical increase in the temperature of the cortical bone, regardless of whether there was a slot in the drill. In particular, the slotted drill had a cooling effect during the initial drilling.
引用
收藏
页码:411 / 421
页数:11
相关论文
共 33 条
[1]   Effect of the use of a surgical guide on heat generation during implant placement: A comparative in vitro study [J].
Alhroob, Khaldoun Hossein ;
Alsabbagh, Mohammed Monzer ;
Alsabbagh, Aghiad Yassin .
DENTAL AND MEDICAL PROBLEMS, 2021, 58 (01) :55-59
[2]   Effect of Guiding Sleeve Design on Intraosseous Heat Generation During Implant Site Preparation (In Vitro Study) [J].
Ashry, Amal ;
Elattar, Mohamed Sherine ;
Elsamni, Osama Ahmed ;
Soliman, Ingy Saied .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (02) :147-154
[3]   Temperature changes during cortical bone drilling with a newly designed step drill and an internally cooled drill [J].
Augustin, Goran ;
Davila, Slavko ;
Udilljak, Toma ;
Staroveski, Tomislav ;
Brezak, Danko ;
Babic, Slaven .
INTERNATIONAL ORTHOPAEDICS, 2012, 36 (07) :1449-1456
[4]   Intraosseous generation of heat during guided surgical drilling: an ex vivo study of the effect of the temperature of the irrigating fluid [J].
Boa, Kristof ;
Barrak, Ibrahim ;
Varga, Endre, Jr. ;
Joob-Fancsaly, Arpad ;
Varga, Endre ;
Piffko, Jozsef .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2016, 54 (08) :904-908
[5]   Types of Implant Surgical Guides in Dentistry: A Review [J].
D'Souza, Kathleen Manuela ;
Aras, Meena Ajay .
JOURNAL OF ORAL IMPLANTOLOGY, 2012, 38 (05) :643-652
[6]   Measurement of thermal conductivity of bovine cortical bone [J].
Davidson, SRH ;
James, DF .
MEDICAL ENGINEERING & PHYSICS, 2000, 22 (10) :741-747
[7]   Evaluation of Bone Heating, Drill Deformation, and Drill Roughness After Implant Osteotomy: Guided Surgery and Classic Drilling Procedure [J].
dos Santos, Pamela Leticia ;
Queiroz, Thallita Pereira ;
Margonar, Rogerio ;
Gomes de Souza Carvalho, Abrahao Cavalcante ;
Betoni, Walter, Jr. ;
Rodrigues Rezende, Regis Rocha ;
dos Santos, Paulo Henrique ;
Garcia, Idelmo Rangel, Jr. .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (01) :51-58
[8]  
Ercoli C, 2004, INT J ORAL MAX IMPL, V19, P335
[9]   THERMAL-INJURY TO BONE - A VITAL-MICROSCOPIC DESCRIPTION OF HEAT-EFFECTS [J].
ERIKSSON, A ;
ALBREKTSSON, T ;
GRANE, B ;
MCQUEEN, D .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1982, 11 (02) :115-121
[10]  
Gehrke SA, 2020, Biology (Basel), V9, P9