摘要
The objective of this research was to (a) determine if blue stain in solid wood influenced calibration equations developed from a non-stained wood population, (b) assess the bias introduced when scanning was performed by the slave instrument without calibration transfer from the master instrument and (c) partition absorbance-based variation by instrument, stain and instrument x stain interaction. The results helped to determine the calibration transfer needed for this case. The dependent variables assessed from clear and stained wood were lignin, extractives, modulus of elasticity (MOE), modulus of rupture (MOR) and density When the master instrument was used for both calibration and prediction, it was found that stain-insensitive equations for the five traits could be built. However, when a slave near infrared instrument was introduced without calibration transfer, three out of five predicted traits were significantly biased by the presence of stain. Further analysis revealed an interaction between stain and instrument indicating that instrument bias was also introduced during scanning with a slave. For both multiple linear regression (MLR) and principal components regression (PCR), it was found that if a trait needed more wavelengths (or principal components) for prediction of the dependent variable, bias due to blue stain became increasingly prominent. PCR was found to perform better than MLR when stain was introduced with no calibration transfer. Such a finding alludes that PCR works better than MLR under extrapolation conditions but is not intended to support a lack of calibration transfer. Finally, the Mallows C P diagnostic proved valuable in model selection although the well-known requirement of (C-P-p <= 0) appeared conservative. For MLR and PCR, a C-P-p <= 5 often yielded applicable models while C-p-p > 7 was about the threshold where model performance dropped.
引用
收藏
页码:201 / 212
页数:12
相关论文
共 50 条
  • [31] Characterization and Prediction of Mechanical and Chemical Properties of Luanta Fir Wood with Vacuum Hydrothermal Treatment
    Hsieh, Ming-Chi
    Hung, Ke-Chang
    Xu, Jin-Wei
    Wu, Yi-Hung
    Chang, Wen-Shao
    Wu, Jyh-Horng
    POLYMERS, 2023, 15 (01)
  • [32] Determination of chemical and biological properties of composts using near infrared spectroscopy
    Michel, Kerstin
    Bruns, Christian
    Terhoeven-Urselmans, Thomas
    Kleikamp, Bernd
    Ludwig, Bernard
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2006, 14 (04) : 251 - 259
  • [33] Estimation of basic density, pulp yield of eucalyptus globulus wood, and pulp mechanical properties by using near infrared spectroscopy.
    Freer, J
    Ruiz, J
    Peredo, M
    Rodriguez, J
    Baeza, J
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 229 : U283 - U283
  • [34] In situ prediction of soil chemical properties with visible and near infrared spectroscopy in an African savannah
    Kuehnel, Anna
    Bogner, Christina
    Huwe, Bernd
    GLOBALSOILMAP: BASIS OF THE GLOBAL SPATIAL SOIL INFORMATION SYSTEM, 2014, : 409 - 413
  • [35] Rapid Prediction of Different Wood Species Extractives and Lignin Content Using Near Infrared Spectroscopy
    He, Wenming
    Hu, Huiren
    JOURNAL OF WOOD CHEMISTRY AND TECHNOLOGY, 2013, 33 (01) : 52 - 64
  • [36] Rapid prediction of solid wood lignin content using transmittance near-infrared spectroscopy
    Yeh, TF
    Chang, HM
    Kadla, JF
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2004, 52 (06) : 1435 - 1439
  • [37] RAPID PREDICTION OF WOOD CELLULOSE, PENTOSAN, AND KLASON LIGNIN CONTENTS USING NEAR INFRARED SPECTROSCOPY
    He Wenming
    Hu Huiren
    Xue Chongyun
    Nie Yi
    RESEARCH PROGRESS IN PAPER INDUSTRY AND BIOREFINERY (4TH ISETPP), VOLS 1-3, 2010, : 157 - 160
  • [38] Prediction performance of portable near infrared reflectance instruments using preprocessed dried, ground forage samples
    Berzaghi, P.
    Cherney, J. H.
    Casler, M. D.
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2021, 182 (182)
  • [39] The challenge of single estimates in near infrared calibration and prediction: the measurement of durum vitreousness using receival instruments
    Wesley, IJ
    Ruggiero, K
    Osborne, BG
    Anderssen, RS
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2005, 13 (06) : 333 - 338
  • [40] Rapid screening of wood chemical component variations using transmittance near-infrared spectroscopy
    Yeh, TF
    Yamada, T
    Capanema, E
    Chang, HM
    Chiang, V
    Kadla, JF
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2005, 53 (09) : 3328 - 3332