Prediction of wood mechanical and chemical properties in the presence and absence of blue stain using two near infrared instruments

被引:20
|
作者
Via, BK [1 ]
So, CL
Shupe, TF
Eckhardt, LG
Stine, M
Groom, LH
机构
[1] Louisiana State Univ, Ctr Agr, Sch Renewable Nat Resources, Baton Rouge, LA 70803 USA
[2] Louisiana State Univ, Dept Plant Pathol, Sch Renewable Nat Resources, Baton Rouge, LA 70803 USA
[3] USDA, Forest Serv, So Res Stn, Pineville, LA USA
关键词
lignin; extractives; density; modulus; NIR; blue stain; Leptographium; Ophiostoma; Mallows; C-P;
D O I
10.1255/jnirs.538
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The objective of this research was to (a) determine if blue stain in solid wood influenced calibration equations developed from a non-stained wood population, (b) assess the bias introduced when scanning was performed by the slave instrument without calibration transfer from the master instrument and (c) partition absorbance-based variation by instrument, stain and instrument x stain interaction. The results helped to determine the calibration transfer needed for this case. The dependent variables assessed from clear and stained wood were lignin, extractives, modulus of elasticity (MOE), modulus of rupture (MOR) and density When the master instrument was used for both calibration and prediction, it was found that stain-insensitive equations for the five traits could be built. However, when a slave near infrared instrument was introduced without calibration transfer, three out of five predicted traits were significantly biased by the presence of stain. Further analysis revealed an interaction between stain and instrument indicating that instrument bias was also introduced during scanning with a slave. For both multiple linear regression (MLR) and principal components regression (PCR), it was found that if a trait needed more wavelengths (or principal components) for prediction of the dependent variable, bias due to blue stain became increasingly prominent. PCR was found to perform better than MLR when stain was introduced with no calibration transfer. Such a finding alludes that PCR works better than MLR under extrapolation conditions but is not intended to support a lack of calibration transfer. Finally, the Mallows C P diagnostic proved valuable in model selection although the well-known requirement of (C-P-p <= 0) appeared conservative. For MLR and PCR, a C-P-p <= 5 often yielded applicable models while C-p-p > 7 was about the threshold where model performance dropped.
引用
收藏
页码:201 / 212
页数:12
相关论文
共 50 条
  • [1] Response of near infrared diffuse reflectance spectra to blue stain and wood age
    Via, Brian K.
    So, Chi-Leung
    Eckhard, Lori G.
    Shupe, Todd F.
    Groom, Leslie H.
    Stine, Michael
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2008, 16 (01) : 71 - 74
  • [2] Use of near infrared spectroscopy to measure the chemical and mechanical properties of solid wood
    Kelley, SS
    Rials, TG
    Snell, R
    Groom, LH
    Sluiter, A
    WOOD SCIENCE AND TECHNOLOGY, 2004, 38 (04) : 257 - 276
  • [3] Use of near infrared spectroscopy to measure the chemical and mechanical properties of solid wood
    Stephen S. Kelley
    Timothy G. Rials
    Rebecca Snell
    Leslie H. Groom
    Amie Sluiter
    Wood Science and Technology, 2004, 38 : 257 - 276
  • [4] Prediction of loblolly pine wood properties using transmittance near-infrared spectroscopy
    Sykes, R
    Li, BL
    Hodge, G
    Goldfarb, B
    Kadla, J
    Chang, HM
    CANADIAN JOURNAL OF FOREST RESEARCH, 2005, 35 (10) : 2423 - 2431
  • [5] ESTIMATION OF THE MECHANICAL PROPERTIES OF WOOD FROM Eucalyptus urophylla USING NEAR INFRARED SPECTROSCOPY
    Andrade, Carlos Rogerio
    Trugilho, Paulo Fernando
    Napoli, Alfredo
    Vieira, Renato da Silva
    Lima, Jose Tarcisio
    de Sousa, Leonardo Chagas
    CERNE, 2010, 16 (03) : 291 - 298
  • [6] The relationship between near infrared spectra of radial wood surfaces and wood mechanical properties
    Gindl, W
    Teischinger, A
    Schwanninger, M
    Hinterstoisser, B
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2001, 9 (04) : 255 - 261
  • [7] Kernel regression methods for the prediction of wood properties of Pinus taeda using near infrared spectroscopy
    Christian R. Mora
    Laurence R. Schimleck
    Wood Science and Technology, 2010, 44 : 561 - 578
  • [8] Kernel regression methods for the prediction of wood properties of Pinus taeda using near infrared spectroscopy
    Mora, Christian R.
    Schimleck, Laurence R.
    WOOD SCIENCE AND TECHNOLOGY, 2010, 44 (04) : 561 - 578
  • [9] Use of Near Infrared Spectroscopy to Measure Mechanical Properties of Solid Wood
    YU Huaqiang ZHAO Rongjun FU Feng FEI Benhua JIANG Zehui Research Institute of Wood Industry
    Chinese Forestry Science and Technology, 2007, (02) : 14 - 19
  • [10] PREDICTION OF STRAND FEEDSTOCK MECHANICAL PROPERTIES WITH NEAR INFRARED SPECTROSCOPY
    Kohan, Neil J.
    Via, Brian K.
    Taylor, Steven E.
    BIORESOURCES, 2012, 7 (03): : 2996 - 3007