Non-linear numerical analysis of a double-threaded titanium alloy dental implant by FEM

被引:25
作者
de Cos Juez, F. J. [2 ]
Sanchez Lasheras, F. [3 ]
Garcia Nieto, P. J. [1 ]
Alvarez-Arenal, A. [4 ]
机构
[1] Univ Oviedo, Dept Math, Oviedo 33007, Spain
[2] Univ Oviedo, Min Exploitat & Prospecting Dept, Oviedo 33004, Spain
[3] Tecniproject SL, Oviedo 33004, Spain
[4] Univ Oviedo, Prosthodont & Occlus Dept, E-33006 Oviedo, Spain
关键词
Finite element modelling; Biomechanics; Numerical methods; Bone implant interactions; Biomaterials;
D O I
10.1016/j.amc.2008.10.019
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
The aim of this work is to study the performance of a double-threaded variable pitch titanium alloy dental implant in a maxillary molar tooth after an implantology treatment by the finite elements method (FEM). The study employed three-dimensional finite elements modelling in order to simulate typical occlusal loads. The three-dimensional basic design of the dental implant, consisting of a dental implant and a piece of jaw, was developed with a three-dimensional parametric design program. One of the major areas of non-linear analysis is the solution of problems where separate bodies or structures may come in contact with each other. The non-linearity due to the contact between the dental implant and the jaw has been taken into account here. In order to study the influence of the variable pitch in the biomechanical behaviour of the dental implant, several configurations of this screw were solved. The nominal occlusal load was applied in all of them. A total of 27 specimens were checked. The stresses and displacements of each are shown in different tables and figures. The optimum configuration was chosen according to these results. From an osseointegration point of view, the optimum dental implant configuration presents a major advantage over the other specimens considered: the bone-implant contact surface is greater than in the other ones and the maximum von Mises stress in the jaw remains close to minimum values. From the biomechanical point of view, one of the specimens was chosen as the best dental implant screw of those checked in the present article. Such selection was made taking into account the stresses produced in its checking and the total bone-implant contact surface. Finally, the stresses of the different elements of the dental implant, the configuration of the optimum dental implant screw as well as conclusions of this research are expounded. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:952 / 967
页数:16
相关论文
共 40 条
[1]  
[Anonymous], 2001, Concepts and Applications of Finite Element Analysis
[2]  
Bathe K, 2007, Finite element procedures
[3]  
Belytschko T., 2000, Nonlinear Finite Elements for Continua and Structures
[4]   The role of parameter identification in finite element contact analyses with reference to orthopaedic biomechanics applications [J].
Bernakiewicz, M ;
Viceconti, M .
JOURNAL OF BIOMECHANICS, 2002, 35 (01) :61-67
[5]  
CHANDRUPATLA TR, 1991, INTRO FINITE ELEMENT
[6]  
Crisfield M.A., 1997, NONLINEAR FINITE ELE
[7]   Analysis of cementless implants using interface nonlinear friction - Experimental and finite element studies [J].
Dammak, M ;
ShiraziAdl, A ;
Zukor, DJ .
JOURNAL OF BIOMECHANICS, 1997, 30 (02) :121-129
[8]   Magnitude and distribution of occlusal forces on oral implants supporting fixed prostheses:: an in vivo study [J].
Duyck, J ;
Van Oosterwyck, H ;
Vander Sloten, J ;
De Cooman, M ;
Puers, R ;
Naert, I .
CLINICAL ORAL IMPLANTS RESEARCH, 2000, 11 (05) :465-475
[9]   Finite element analysis of three designs of an implant-supported molar crown [J].
Geramy, A ;
Morgano, SM .
JOURNAL OF PROSTHETIC DENTISTRY, 2004, 92 (05) :434-440
[10]   Wear analysis of materials used as orthopaedic implants [J].
Geringer, Jean ;
Forest, Bernard ;
Combrade, Pierre .
WEAR, 2006, 261 (09) :971-979