The effect of geometry factors on fenestration energy performance and energy savings in office buildings

被引:115
作者
Susorova, Irina [1 ]
Tabibzadeh, Meysam [1 ]
Rahman, Anisur [1 ]
Clack, Herek L. [1 ]
Elnimeiri, Mahjoub [1 ]
机构
[1] IIT, Coll Architecture, Chicago, IL 60616 USA
关键词
Energy-efficient fenestration; Energy savings; Building energy performance; Geometry factors; Energy simulations; SIMULATION;
D O I
10.1016/j.enbuild.2012.10.035
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Although there have been multiple studies on window thermal properties in energy-efficient fenestration design, the effects of building geometry factors have been studied much less. The study presented in this paper evaluated the role of geometry factors, such as window orientation, window to wall ratio, and room width to depth ratio, on building energy performance in a commercial office building. A series of energy simulations were performed for six climate zones in the United States using a model of a room in a typical office building created in Design Builder, an energy analysis program, to evaluate total annual energy consumption. The simulation results were analyzed to find the combination of parameters yielding the lowest energy consumption and to define potential energy savings for office buildings located in various climate zones. The study showed that geometry factors affect energy consumption significantly in hot climates (Zones 2 and 3) and cold climates (Zones 6 and 7) but only marginally in temperate climates (Zones 4 and 5). Energy savings were on average 3% and 6% reaching a maximum of 10% and 14% in hot climates (Zones 2 and 3) and 1% in temperate and cold climates (Zones 4-7). (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:6 / 13
页数:8
相关论文
共 9 条
[1]  
[Anonymous], 2011, BUILD EN DAT BOOK
[2]  
[Anonymous], 2010, 901 ASHRAE
[3]  
Carmody J, 2004, WINDOWS SYSTEMS HIGH
[4]   An ETTV-based approach to improving the energy performance of commercial buildings [J].
Chua, K. J. ;
Chou, S. K. .
ENERGY AND BUILDINGS, 2010, 42 (04) :491-499
[5]   An Ideal Window Area concept for energy efficient integration of daylight and artificial light in buildings [J].
Ghisi, E ;
Tinker, JA .
BUILDING AND ENVIRONMENT, 2005, 40 (01) :51-61
[6]   GLAZING ENERGY PERFORMANCE AND DESIGN OPTIMIZATION WITH DAYLIGHTING [J].
JOHNSON, R ;
SULLIVAN, R ;
SELKOWITZ, S ;
NOZAKI, S ;
CONNER, C ;
ARASTEH, D .
ENERGY AND BUILDINGS, 1984, 6 (04) :305-317
[7]  
Ko D.-H., 2009, Fenestration guideline for energy and daylight efficiency: Evaluation and prediction of performance in office buildings
[8]   SIMULATION BASED COMPLEX ENERGY ASSESSMENT OF OFFICE BUILDING FENESTRATION [J].
Motuziene, Violeta ;
Juodis, Egidijus Saulius .
JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT, 2010, 16 (03) :345-351
[9]   Simulation of facade and envelope design options for a new institutional building [J].
Tzempelikos, Athanassios ;
Athienitis, Andreas K. ;
Karava, Panagiota .
SOLAR ENERGY, 2007, 81 (09) :1088-1103