X-ray Knee as a Screening Tool for Osteoporosis

被引:4
|
作者
Agarwal, Shweta [1 ]
Das, Siddharth K. [1 ]
Agarwal, Girdhar G. [2 ]
Srivastava, Ragini [1 ]
Singh, Gyanendra P. [2 ]
机构
[1] CSM Med Univ, Dept Rheumatol, Lucknow 260018, Uttar Pradesh, India
[2] Univ Lucknow, Dept Stat, Lucknow 226007, Uttar Pradesh, India
关键词
BMD; DXA; cortical thickness; tibia; ELDERLY-WOMEN; RADIOGRAMMETRY; THICKNESS; DENSITY;
D O I
10.1016/j.jocd.2012.02.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cortical thickness (Cor-Th) of tibia varies considerably on X-ray knees. It was hypothesized that Cor-Th can be used for preliminary prediction of BMD. Ninety nine patients underwent a digital X-ray left knee fixed flexion PA view with an external calibration scale attached to X-ray plate and BMD by DXA using GE lunar machine (Madison, Wisconsin.). Cor-Th was measured at 5 selected levels (A,B,C,D, and E) ranging from 5-7 cm below the tibial plateau on its medial aspect. T-scores were recorded for BMD at AP spine, left forearm and left femur. Cor-Th of tibia at each level significantly correlated with each site of BMD measurement namely AP spine, left femur and left forearm. This correlation varied in the range from 0.241 to 0.426. For AP spine, it was maximum at level C (r = 0.347, p < 0.001) whereas for left femur and forearm sites, it was maximum at level B (r = 0.426 & r = 0.373 respectively, p < 0.001). The correlation of Cor-Th with BMD varied with age. Above 56 years of age, Cor-Th at each level significantly correlated to BMD at each site. Medial tibial cortical thickness, 6 cm (level C) below tibial plateau can be used as preliminary predictor of patients who need a DXA scan.
引用
收藏
页码:362 / 365
页数:4
相关论文
共 50 条
  • [41] Degeneration of the lumbar spine and dual-energy X-ray absorptiometry measurements in patients without osteoporosis
    Atalay, Ayce
    Kozakcioglu, Meral
    Cubuk, Rahmi
    Tasali, Nuri
    Guney, Sefik
    CLINICAL IMAGING, 2009, 33 (05) : 374 - 378
  • [42] Comparison of Quantitative Computed Tomography and Dual X-Ray Absorptiometry: Osteoporosis Detection Rates in Diabetic Patients
    Dheeraj, Dheeraj
    Chauhan, Udit
    Khapre, Meenakshi
    Kant, Ravi
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (03)
  • [43] Screening response of valence and core electrons in a metal: Inelastic x-ray scattering study
    Hiraoka, N.
    Hagiya, T.
    Matsuda, K.
    PHYSICAL REVIEW B, 2023, 108 (19)
  • [44] X-ray scattering tomography
    Gorshkov, V. A.
    Kroening, M.
    Anosov, Y. V.
    Dorjgochoo, O.
    NONDESTRUCTIVE TESTING AND EVALUATION, 2005, 20 (03) : 147 - 157
  • [45] The trabecular bone index: a new tool for assessing osteoporosis
    Olmos, J. M.
    Gonzalez-Macias, J.
    REVISTA CLINICA ESPANOLA, 2018, 218 (03): : 135 - 136
  • [46] X-ray microscopy and talbot imaging with the matter in extreme conditions X-ray imager at LCLS
    Galtier, Eric
    Lee, Hae Ja
    Khaghani, Dimitri
    Boiadjieva, Nina
    Mcgehee, Peregrine
    Arnott, Ariel
    Arnold, Brice
    Berboucha, Meriame
    Cunningham, Eric
    Czapla, Nick
    Dyer, Gilliss
    Ettelbrick, Robert
    Hart, Philip
    Heimann, Philip
    Welch, Marc
    Makita, Mikako
    Gleason, Arianna E.
    Pandolfi, Silvia
    Sakdinawat, Anne
    Liu, Yanwei
    Wojcik, Michael J.
    Hodge, Daniel
    Sandberg, Richard
    Valdivia, Maria Pia
    Bouffetier, Victorien
    Perez-Callejo, Gabriel
    Seiboth, Frank
    Nagler, Bob
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [47] Development of a new X-ray scattering instrument based on two polycapillary X-ray optics
    Zhang, Xiaoyun
    Wang, Yabing
    Shao, Shangkun
    Li, Yufei
    Liu, Zhiguo
    Sun, Tianxi
    Sun, Xuepeng
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 984
  • [48] Portable energy dispersive X-ray fluorescence and X-ray diffraction and radiography system for archaeometry
    Mendoza Cuevas, Ariadna
    Perez Gravie, Homero
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 633 (01) : 72 - 78
  • [49] In situ characterization of liquids at high pressure combining X-ray tomography, X-ray diffraction and X-ray absorption using the white beam station at PSICHE
    Henry, L.
    Guignot, N.
    King, A.
    Giovenco, E.
    Deslandes, J-P
    Itie, J-P
    JOURNAL OF SYNCHROTRON RADIATION, 2022, 29 : 853 - 861
  • [50] Dual energy X-ray absorptiometry is a valid tool for assessing in vivo body composition of broilers
    Goncalves, Camila Angelica
    Sakomura, Nilva Kazue
    da Silva, Edney Pereira
    Baraldi Artoni, Silvana Martinez
    Suzuki, Rafael Massami
    Gous, Robert Mervyn
    ANIMAL PRODUCTION SCIENCE, 2019, 59 (05) : 993 - 1000