Study of Time Characteristic Test Method of the Fast Timing MCP-PMT

被引:1
|
作者
Zhu, Yao [1 ]
Qian, Sen [2 ]
Wang, Zhigang [2 ]
Ning, Zhe [2 ]
Wang, Yang [3 ]
Wu, Qi [5 ]
Li, Haitao [6 ]
Ma, Lishuang [1 ]
Chen, Pengyu [4 ]
Gao, Feng [7 ]
Hu, Qianyu [5 ]
Guo, Hao [4 ]
Peng, Shuo [2 ]
Wang, Zhile [1 ]
机构
[1] Harbin Inst Technol, Dept Elect Sci & Technol, Harbin 150001, Peoples R China
[2] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
[3] Tianjin Univ Technol, Sch Elect & Elect Engn, Tianjin 300384, Peoples R China
[4] North China Univ Technol, Sch Mech & Mat Engn, Beijing 100144, Peoples R China
[5] Zhengzhou Univ, Dept Phys, Zhengzhou 450001, Peoples R China
[6] Sun Yat Sen Univ, Sch Phys, Guangzhou 510275, Peoples R China
[7] Rhein Westfal TH Aachen, Dept Phys, D-52074 Aachen, Germany
来源
2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2019年
基金
中国国家自然科学基金;
关键词
Photomultiplier tube; microchannel plate; time characteristic; PLATE PHOTOMULTIPLIER TUBE;
D O I
10.1109/nss/mic42101.2019.9059973
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Compared with the traditional large dynode photomultiplier tube (PMT), the small size microchannel plate (MCP) PMT has better time properties. In particular, the small size MCP-PMT of proximity focusing construction has many advantages such as excellent time characteristics and strong magnetic field resistance. The time characteristics of various 1 inch fast timing MCP-PMTs (FPMTs) are tested under different light intensity in our laboratory. Two methods are adopted to test time characteristics. The result shows that the minimum value of the time resolution can be fitted by testing the change of transition time spread (TTS) with photoelectrons. In addition, the magnetic field does not have much effect on the time resolution of the FPMT.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Study on fast timing MCP-PMT in magnetic fields from simulation and measurement
    Zhu, Yao
    Qian, Sen
    Wu, Qi
    Zhang, Guoqing
    Ma, Lishuang
    Wang, Zhile
    SENSORS AND ACTUATORS A-PHYSICAL, 2021, 318
  • [2] R & D of a novel single anode fast timing MCP-PMT
    Ma, Lishuang
    Huang, Guorui
    Hua, Zhehao
    Jin, Muchun
    Jin, Zhen
    Liu, Shulin
    Qian, Sen
    Ren, Lin
    Si, Shuguang
    Sun, Jianning
    Wu, Qi
    Wang, Xingchao
    Wang, Yifang
    Wang, Zhile
    Wang, Zhi
    Wang, Ning
    Wu, Kai
    Yan, Min
    Zhang, Haoda
    Zhu, Yao
    MCP-PMT workgrp
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1041
  • [3] MCP-PMT timing property for single photons
    Akatsu, M
    Enari, Y
    Hayasaka, K
    Hokuue, T
    Iijima, T
    Inami, K
    Itoh, K
    Kawakami, Y
    Kishimoto, N
    Kubota, T
    Kojima, M
    Kozakai, Y
    Kuriyama, Y
    Matsuishi, T
    Miyabayashi, Y
    Ohshima, T
    Sato, N
    Senyo, K
    Sugi, A
    Tokuda, S
    Tomita, M
    Yanase, H
    Yoshino, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 528 (03): : 763 - 775
  • [4] Timing Performance of Cherenkov-Radiator-Integrated MCP-PMT
    Ota, Rsyoke
    Nakajima, Kyohei
    Ogawa, Izumi
    Tamagawa, Yoichi
    Shimoi, Hideki
    Suyama, Motohiro
    Hasegawa, Tomoyuki
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [5] Large area MCP-PMT design with good time performance
    Chen, Lin
    Wang, Xingchao
    He, Jianli
    Tian, Liping
    Tian, Jinshou
    Wang, Yunji
    OPTICS EXPRESS, 2022, 30 (14): : 25918 - 25925
  • [6] The Status of the 20 inch MCP-PMT and its APR Test Result
    Wu, Qi
    Qian, Sen
    Cao, Yiqi
    Huang, Guorui
    Jin, Muchun
    Jin, Zhen
    Li, Dong
    Li, Kun
    Liu, Shulin
    Ma, Lishuang
    Ren, Ling
    Si, Shuguang
    Sun, Jianning
    Wang, Xingchao
    Zhang, Haoda
    Zhu, Yao
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [7] Test of a novel 2 * 2 multi-anode MCP-PMT
    Ziwei Li
    Xin Li
    Ping Chen
    Cheng Li
    Yonglin Wei
    Xiaofeng Sai
    Jianbei Liu
    Ming Shao
    Jinshou Tian
    Hulin Liu
    Radiation Detection Technology and Methods, 2020, 4 : 472 - 477
  • [8] Test of a novel 2*2 multi-anode MCP-PMT
    Li, Ziwei
    Li, Xin
    Chen, Ping
    Li, Cheng
    Wei, Yonglin
    Sai, Xiaofeng
    Liu, Jianbei
    Shao, Ming
    Tian, Jinshou
    Liu, Hulin
    RADIATION DETECTION TECHNOLOGY AND METHODS, 2020, 4 (04) : 472 - 477
  • [9] Study on the large area MCP-PMT glass radioactivity reduction
    Zhang, Xuantong
    Zhao, Jie
    Liu, Shulin
    Niu, Shunli
    Han, Xiaoming
    Wen, Liangjian
    He, Jincheng
    Hu, Tao
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 898 : 67 - 71
  • [10] Study on the tail in TDOE of the coated MCP-PMT and its suppression
    Chen, Lin
    Wang, Xingchao
    Tian, Jinshou
    Fan, Lixing
    Tian, Liping
    Shen, Lingbin
    OPTOELECTRONIC DEVICES AND INTEGRATION VIII, 2019, 11184