Continuous glucose monitoring: A review of biochemical perspectives and clinical use in type 1 diabetes

被引:63
作者
Girardin, Celine M. [1 ]
Huot, Celine [1 ]
Gonthier, Monique [1 ]
Delvin, Edgard [2 ]
机构
[1] Univ Montreal, CHU St Justine, Dept Pediat, Montreal, PQ H3T 1C5, Canada
[2] Univ Montreal, CHU St Justine, Dept Biochem, Montreal, PQ H3T 1C5, Canada
关键词
Diabetes; Glucose control; Transcutaneous glucose monitoring; IMPROVED GLYCEMIC CONTROL; BLOOD-GLUCOSE; PEDIATRIC-PATIENTS; SYSTEM; ACCURACY; CHILDREN; SENSOR; HYPOGLYCEMIA; FEASIBILITY; ADOLESCENTS;
D O I
10.1016/j.clinbiochem.2008.09.112
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Self-monitoring of blood glucose is a fundamental part of diabetes management. It is mandatory for tight glucose control. For the past 30 years, intermittent measurement of capillary blood glucose has been the method of choice for self-monitoring. The main disadvantage of such measurements is that they provide isolated glucose values which do not reflect variations occurring throughout the day and night. Hence systems monitoring blood glucose concentrations on a "continuous basis" have been developed. In clinical studies, different devices were shown to provide useful information on glycemic excursions in people with diabetes with sufficient accuracy. Thus, in clinical practice, this approach has also been shown to help in the medical management leading to a reduction in glycated hemoglobin and glycemic variability. However, because of lack of experience, this technology has yet to replace standard capillary blood glucose monitoring. In this paper, we review the biochemical perspectives of continuous glucose monitoring and its clinical use in type 1 diabetes. (C) 2008 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:136 / 142
页数:7
相关论文
共 52 条
  • [1] Reduction in hemoglobin A1c with real-time continuous glucose monitoring: Results from a 12-week observational study
    Bailey, Timothy S.
    Zisser, Howard C.
    Garg, Satish K.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2007, 9 (03) : 203 - 210
  • [2] Recording of subcutaneous glucose dynamics by a viscometric affinity sensor
    Beyer, U
    Schäfer, D
    Thomas, A
    Aulich, H
    Haueter, U
    Reihl, B
    Ehwald, R
    [J]. DIABETOLOGIA, 2001, 44 (04) : 416 - 423
  • [3] Bode Bruce, 2004, Diabetes Technol Ther, V6, P105, DOI 10.1089/152091504773731285
  • [4] Continuous glucose monitoring used to adjust diabetes therapy improves glycosylated hemoglobin: a pilot study
    Bode, BW
    Gross, TM
    Thornton, KR
    Mastrototaro, JJ
    [J]. DIABETES RESEARCH AND CLINICAL PRACTICE, 1999, 46 (03) : 183 - 190
  • [5] Self-monitoring of blood glucose in type I diabetic patients: Comparison with continuous microdialysis measurements of glucose in subcutaneous adipose tissue during ordinary life conditions
    Bolinder, J
    HagstromToft, E
    Ungerstedt, U
    Arner, P
    [J]. DIABETES CARE, 1997, 20 (01) : 64 - 70
  • [6] Self-monitoring of blood glucose in children and teens with diabetes
    Bui, H
    Perlman, K
    Daneman, D
    [J]. PEDIATRIC DIABETES, 2005, 6 (01) : 50 - 62
  • [7] First human experiments with a novel non-invasive, non-optical continuous glucose monitoring system
    Caduff, A
    Hirt, E
    Feldman, Y
    Ali, Z
    Heinemann, L
    [J]. BIOSENSORS & BIOELECTRONICS, 2003, 19 (03) : 209 - 217
  • [8] The continuous glucose monitoring system is useful for detecting unrecognized hypoglycemias in patients with type 1 and type 2 diabetes but is not better than frequent capillary glucose measurements for improving metabolic control
    Chico, A
    Vidal-Ríos, P
    Subirà, M
    Novials, A
    [J]. DIABETES CARE, 2003, 26 (04) : 1153 - 1157
  • [9] EVALUATING CLINICAL ACCURACY OF SYSTEMS FOR SELF-MONITORING OF BLOOD-GLUCOSE
    CLARKE, WL
    COX, D
    GONDERFREDERICK, LA
    CARTER, W
    POHL, SL
    [J]. DIABETES CARE, 1987, 10 (05) : 622 - 628
  • [10] Accuracy and feasibility of point-of-care and continuous blood glucose analysis in critically ill ICU patients
    Corstjens, Anouk M.
    Ligtenberg, Jack J. M.
    van der Horst, Iwan C. V.
    Spanjersberg, Rob
    Lind, Joline S. W.
    Tulleken, Jaap E.
    Meertens, John H. J. M.
    Zijlstra, Jan G.
    [J]. CRITICAL CARE, 2006, 10 (05):