Error images for spectroscopic imaging by LCModel using Cramer-Rao bounds

被引:34
作者
Jiru, F [1 ]
Skoch, A [1 ]
Klose, U [1 ]
Grodd, W [1 ]
Hajek, M [1 ]
机构
[1] Univ Tubingen, Dept Neuroradiol, Sect Expt MR CNS, Tubingen, Germany
关键词
spectroscopic imaging; error images; LCModel; Cramer-Rao bounds;
D O I
10.1007/s10334-005-0018-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The results of spectroscopic imaging (SI) measurements are often presented as metabolic images. If the spectra quality is not sufficient, the calculated concentrations are biased and the metabolic images show an incorrect metabolite distribution. To simplify the quality analysis of spectra measured by SI, an error image, reflecting the accuracy of the computed concentrations, can be displayed along with the metabolite image. In this paper the relevance of Cramer-Rao bounds (CRBs) calculated by the LCModel program to describe errors in estimated concentrations is validated using spectra simulations. The relation between the average CRBs and standard deviations (STD) of metabolite concentrations from 100 simulated spectra for various signal to noise ratio and line broadening conditions is evaluated. A parameter for calculating error images for metabolite ratios is proposed and an effective way to display error images is shown. The results suggest that the average CRBs are strongly correlated with the standard deviations and hence that CRB values reflect the relative uncertainty of the calculated concentrations. The error information can be integrated directly into a metabolite image by displaying only those areas of the metabolite image with corresponding CRBs below a selected threshold or by mapping CRBs as a transparency of the metabolite image. The concept of error images avoids extensive examination of each SI spectrum and helps to reject low quality spectra.
引用
收藏
页码:1 / 14
页数:14
相关论文
共 25 条
[1]   ERROR THEORY FOR TIME-DOMAIN SIGNAL ANALYSIS WITH LINEAR PREDICTION AND SINGULAR VALUE DECOMPOSITION [J].
BARKHUIJSEN, H ;
DEBEER, R ;
VANORMONDT, D .
JOURNAL OF MAGNETIC RESONANCE, 1986, 67 (02) :371-375
[2]   NMR CHEMICAL-SHIFT IMAGING IN 3 DIMENSIONS [J].
BROWN, TR ;
KINCAID, BM ;
UGURBIL, K .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA-BIOLOGICAL SCIENCES, 1982, 79 (11) :3523-3526
[3]   Cramer-Rao bound expressions for parametric estimation of overlapping peaks: Influence of prior knowledge [J].
Cavassila, S ;
Deval, S ;
Huegen, C ;
van Ormondt, D ;
Graveron-Demilly, D .
JOURNAL OF MAGNETIC RESONANCE, 2000, 143 (02) :311-320
[4]   Cramer-Rao bounds: an evaluation tool for quantitation [J].
Cavassila, S ;
Deval, S ;
Huegen, C ;
van Ormondt, D ;
Graveron-Demilly, D .
NMR IN BIOMEDICINE, 2001, 14 (04) :278-283
[5]   Assessment of 3D proton MR echo-planar spectroscopic imaging using automated spectral analysis [J].
Ebel, A ;
Soher, BJ ;
Maudsley, AA .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (06) :1072-1078
[6]   MR relaxometry and 1H MR spectroscopy for the determination of iron and metabolite concentrations in PKAN patients [J].
Hájek, M ;
Adamovicová, M ;
Herynek, V ;
Skoch, A ;
Jíru, F ;
Krepelová, A ;
Dezortová, M .
EUROPEAN RADIOLOGY, 2005, 15 (05) :1060-1068
[7]   Quantitative 1H-magnetic resonance spectroscopy of human brain:: Influence of composition and parameterization of the basis set in linear combination model-fitting [J].
Hofmann, L ;
Slotboom, J ;
Jung, B ;
Maloca, P ;
Boesch, C ;
Kreis, R .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (03) :440-453
[8]  
JIRU F, 2004, P 21 ANN SCI M ESMRM
[9]  
JIRU F, 2002, P ANN SCI M ESMRMB M, V1, P368
[10]   Quantitation of simulated short echo time 1H human brain spectra by LCModel and AMARES [J].
Kanowski, M ;
Kaufmann, J ;
Braun, J ;
Bernarding, J ;
Tempelmann, C .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (05) :904-912