Locked Versus Nonlocked Plate Fixation for First Metatarsophalangeal Arthrodesis: A Biomechanical Investigation

被引:27
|
作者
Hunt, Kenneth J. [1 ]
Barr, Cameron R. [1 ]
Lindsey, Derek P. [2 ]
Chou, Loretta B. [1 ]
机构
[1] Stanford Univ, Dept Orthopaed, Redwood City, CA 94063 USA
[2] VA Palo Alto Hlth Care Syst, Ctr Tissue Regenerat Repair & Restorat, Palo Alto, CA USA
关键词
First Metatarsophalangeal Arthrodesis; Hallux Rigidus; Hallux Valgus; Locked Plate; DOME-SHAPED REAMERS; JOINT ARTHRODESIS; DORSAL PLATE; FRACTURES; STIFFNESS; FAILURE; FEMUR; GAIT; LCP;
D O I
10.3113/FAI.2012.0984
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: First metatarsophalangeal (MTP) arthrodesis using dorsal plate fixation is a common procedure for painful conditions of the great toe. Locked plates have become increasingly common for arthrodesis procedures in the foot, including the hallux MTP joint. The biomechanical advantages and disadvantages of these plates are currently unknown. The purpose of this study was to compare locked and nonlocked plates used for first MTP fusion for strength and stiffness. Materials and Methods: The first ray of nine matched pairs of fresh-frozen cadaveric feet underwent dissection, preparation with cup-and-cone reamers, and fixation of the MTP joint with a compression screw and either a nonlocked or locked stainless steel dorsal plate. Each specimen was loaded in a cantilever fashion to 90 N at a rate of 3 Hz for a total of 250,000 cycles. The amount of plantar MTP gap was recorded using a calibrated extensometer. Load-to-failure testing was performed for all specimens that endured the entire cyclical loading. Stiffness was calculated from the final load-to-failure test. Results: The locked plate group demonstrated significantly less plantar gapping during fatigue endurance testing from cycle 10,000 through 250,000 (p < .05). Mean stiffness was significantly greater in the locked plate group compared with the nonlocked plate group (p = .02). There was no significant difference in load to failure between the two groups (p = .27). Conclusion: Compared with nonlocked plates, locked hallux MTP arthrodesis plates exhibited significantly less plantar gapping after 10,000 cycles of fatigue endurance testing and significantly greater stiffness in load-to-failure testing. Clinical Relevance: As the use of locked plate technology is becoming increasingly common for applications in the foot, a thorough understanding of the biomechanical characteristics of these implants may help optimize their indications and clinical use.
引用
收藏
页码:984 / 990
页数:7
相关论文
共 50 条
  • [41] Different fixation constructs and the risk of non-union following first metatarsophalangeal joint arthrodesis
    Cichero, Matthew J.
    Yates, Ben J.
    Joyce, Anthony S. D.
    Williamson, David M.
    Walsh, Tom P.
    FOOT AND ANKLE SURGERY, 2021, 27 (07) : 789 - 792
  • [42] Effect of joint pathology, surface preparation and fixation methods on union frequency after first metatarsophalangeal joint arthrodesis: A systematic review of the English literature
    Korim, Muhammad Tawfiq
    Mahadevan, Devendra
    Ghosh, Arijit
    Mangwani, Jitendra
    FOOT AND ANKLE SURGERY, 2017, 23 (03) : 189 - 194
  • [43] Low-profile Titanium Plate Construct for Early Weightbearing with First Metatarsophalangeal Joint Arthrodesis
    Mann, Joshua J.
    Moon, Jared L.
    Brosky, Thomas A., II
    JOURNAL OF FOOT & ANKLE SURGERY, 2013, 52 (04) : 460 - 464
  • [44] Locked plate fixation and intramedullary nailing for proximal humerus fractures: A biomechanical evaluation
    Hessmann, MH
    Hansen, WSM
    Krummenauer, F
    Pol, TF
    Rommens, M
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 58 (06): : 1194 - 1201
  • [45] Posterolateral plate fixation with Talarlock® is more stable than screw fixation in ankle arthrodesis in a biomechanical cadaver study
    Gutteck, N.
    Martin, H.
    Hanke, T.
    Matthies, J. B.
    Heilmann, A.
    Kielstein, H.
    Gradl, G.
    Delank, K. S.
    Wohlrab, D.
    FOOT AND ANKLE SURGERY, 2018, 24 (03) : 208 - 212
  • [46] Functional Results and Patient Satisfaction of First Metatarsophalangeal Joint Arthrodesis Using Dual Crossed Screw Fixation
    Donegan, Ryan J.
    Blume, Peter A.
    JOURNAL OF FOOT & ANKLE SURGERY, 2017, 56 (02) : 291 - 297
  • [47] Two Orthogonal Nitinol Staples and Combined Nitinol Staple-Screw Constructs for a First Metatarsophalangeal Joint Arthrodesis: A Biomechanical Cadaver Study
    Schafer, Kevin A.
    Baldini, Todd
    Hamati, Mary
    Backus, Jonathon D.
    Hunt, Kenneth J.
    McCormick, Jeremy J.
    FOOT & ANKLE INTERNATIONAL, 2022, 43 (11) : 1493 - 1500
  • [48] Scarf osteotomy versus metatarsophalangeal arthrodesis in forefoot first ray disorders: Comparison of functional outcomes
    Desmarchelier, R.
    Besse, J. -L.
    Fessy, M. -H.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2012, 98 (06) : S77 - S84
  • [49] Biomechanical comparison of first metatarsophalangeal joint arthrodeses using triple-threaded headless screws versus partially threaded lag screws
    Lucas, Kurt J.
    Morris, Randal P.
    Buford, William L., Jr.
    Panchbhavi, Vinod K.
    FOOT AND ANKLE SURGERY, 2014, 20 (02) : 144 - 148
  • [50] First Metatarsophalangeal Fusion with Ball-and-Socket Bone Preparation and a Dorsal Plate Fixation
    Trnka, Hans-Joerg
    Hofstaetter, Stefan
    TECHNIQUES IN FOOT AND ANKLE SURGERY, 2006, 5 (01): : 54 - 59