Gene-Z: a device for point of care genetic testing using a smartphone

被引:139
作者
Stedtfeld, Robert D.
Tourlousse, Dieter M.
Seyrig, Gregoire
Stedtfeld, Tiffany M.
Kronlein, Maggie
Price, Scott
Ahmad, Farhan
Gulari, Erdogan [3 ]
Tiedje, James M. [1 ,2 ]
Hashsham, Syed A. [1 ]
机构
[1] Michigan State Univ, Ctr Microbial Ecol, E Lansing, MI 48824 USA
[2] Michigan State Univ, Dept Microbiol & Mol Genet, E Lansing, MI 48824 USA
[3] Univ Michigan, Dept Chem Engn, Ann Arbor, MI 48109 USA
基金
美国国家卫生研究院;
关键词
MEDIATED ISOTHERMAL AMPLIFICATION; REAL-TIME PCR; QUANTITATIVE DETECTION; REVERSE-TRANSCRIPTION; RAPID DETECTION; WISHES; LAMP; TECHNOLOGIES; CHIP;
D O I
10.1039/c2lc21226a
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
By 2012, point of care (POC) testing will constitute roughly one third of the $59 billion in vitro diagnostics market. The ability to carry out multiplexed genetic testing and wireless connectivity are emerging as key attributes of future POC devices. In this study, an inexpensive, user-friendly and compact device (termed Gene-Z) is presented for rapid quantitative detection of multiple genetic markers with high sensitivity and specificity. Using a disposable valve-less polymer microfluidic chip containing four arrays of 15 reaction wells each with dehydrated primers for isothermal amplification, the Gene-Z enables simultaneous analysis of four samples, each for multiple genetic markers in parallel, requiring only a single pipetting step per sample for dispensing. To drastically reduce the cost and size of the real-time detector necessary for quantification, loop-mediated isothermal amplification (LAMP) was performed with a high concentration of SYTO-81, a non-inhibiting fluorescent DNA binding dye. The Gene-Z is operated using an iPod Touch, which also receives data and carries out automated analysis and reporting via a WiFi interface. This study presents data pertaining to performance of the device including sensitivity and reproducibility using genomic DNA from Escherichia coli and Staphylococcus aureus. Overall, the Gene-Z represents a significant step toward truly inexpensive and compact tools for POC genetic testing.
引用
收藏
页码:1454 / 1462
页数:9
相关论文
共 50 条
[41]   Real-time PCR-based microfluidic array chip for simultaneous detection of multiple waterborne pathogens [J].
Ramalingam, Naveen ;
Rui, Zhang ;
Liu, Hao-Bing ;
Dai, Chang-Chun ;
Kaushik, Rajni ;
Ratnaharika, Bandi ;
Gong, Hai-Qing .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 145 (01) :543-552
[42]   Miniaturized high throughput detection system for capillary array electrophoresis on chip with integrated light emitting diode array as addressed ring-shaped light source [J].
Ren, Kangning ;
Liang, Qionglin ;
Mu, Xuan ;
Luo, Guoan ;
Wang, Yiming .
LAB ON A CHIP, 2009, 9 (05) :733-736
[43]  
Seyrig G., 2011, SIMPLE POWERFUL SMAR
[44]  
Seyrig G., 2011, UNPUB
[45]   Multiplexed Quantification of Nucleic Acids with Large Dynamic Range Using Multivolume Digital RT-PCR on a Rotational SlipChip Tested with HIV and Hepatitis C Viral Load [J].
Shen, Feng ;
Sun, Bing ;
Kreutz, Jason E. ;
Davydova, Elena K. ;
Du, Wenbin ;
Reddy, Poluru L. ;
Joseph, Loren J. ;
Ismagilov, Rustem F. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2011, 133 (44) :17705-17712
[46]   Genotypic and Phenotypic Characterization of Methicillin-Susceptible Staphylococcus aureus Isolates Misidentified as Methicillin-Resistant Staphylococcus aureus by the BD GeneOhm MRSA Assay [J].
Stamper, Paul D. ;
Louie, Lisa ;
Wong, Henry ;
Simor, Andrew E. ;
Farley, Jason E. ;
Carroll, Karen C. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (04) :1240-1244
[47]   Development and experimental validation of a predictive threshold cycle equation for quantification of virulence and marker genes by high-throughput nanoliter-volume PCR on the OpenArray platform [J].
Stedtfeld, Robert D. ;
Baushke, Samuel W. ;
Tourlousse, Dieter M. ;
Miller, Sarah M. ;
Stedtfeld, Tiffany M. ;
Gulari, Erdogan ;
Tiedje, James M. ;
Hashsham, Syed A. .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2008, 74 (12) :3831-3838
[48]   Helicase-dependent isothermal DNA amplification [J].
Myriam Vincent ;
Yan Xu ;
Huimin Kong .
The EMBO Reports, 2004, 5 (8) :795-800
[49]   Ultrasonication on a microfluidic chip to lyse single and multiple Pseudo-nitzschia for marine biotoxin analysis [J].
Wu, Chunsheng ;
Lillehoj, Peter B. ;
Sabet, Leyla ;
Wang, Ping ;
Ho, Chih-Ming .
BIOTECHNOLOGY JOURNAL, 2011, 6 (02) :150-155
[50]  
Yao D., 2008, J MICROMECH MICROENG, V18, P7