Gene-Z: a device for point of care genetic testing using a smartphone

被引:139
作者
Stedtfeld, Robert D.
Tourlousse, Dieter M.
Seyrig, Gregoire
Stedtfeld, Tiffany M.
Kronlein, Maggie
Price, Scott
Ahmad, Farhan
Gulari, Erdogan [3 ]
Tiedje, James M. [1 ,2 ]
Hashsham, Syed A. [1 ]
机构
[1] Michigan State Univ, Ctr Microbial Ecol, E Lansing, MI 48824 USA
[2] Michigan State Univ, Dept Microbiol & Mol Genet, E Lansing, MI 48824 USA
[3] Univ Michigan, Dept Chem Engn, Ann Arbor, MI 48109 USA
基金
美国国家卫生研究院;
关键词
MEDIATED ISOTHERMAL AMPLIFICATION; REAL-TIME PCR; QUANTITATIVE DETECTION; REVERSE-TRANSCRIPTION; RAPID DETECTION; WISHES; LAMP; TECHNOLOGIES; CHIP;
D O I
10.1039/c2lc21226a
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
By 2012, point of care (POC) testing will constitute roughly one third of the $59 billion in vitro diagnostics market. The ability to carry out multiplexed genetic testing and wireless connectivity are emerging as key attributes of future POC devices. In this study, an inexpensive, user-friendly and compact device (termed Gene-Z) is presented for rapid quantitative detection of multiple genetic markers with high sensitivity and specificity. Using a disposable valve-less polymer microfluidic chip containing four arrays of 15 reaction wells each with dehydrated primers for isothermal amplification, the Gene-Z enables simultaneous analysis of four samples, each for multiple genetic markers in parallel, requiring only a single pipetting step per sample for dispensing. To drastically reduce the cost and size of the real-time detector necessary for quantification, loop-mediated isothermal amplification (LAMP) was performed with a high concentration of SYTO-81, a non-inhibiting fluorescent DNA binding dye. The Gene-Z is operated using an iPod Touch, which also receives data and carries out automated analysis and reporting via a WiFi interface. This study presents data pertaining to performance of the device including sensitivity and reproducibility using genomic DNA from Escherichia coli and Staphylococcus aureus. Overall, the Gene-Z represents a significant step toward truly inexpensive and compact tools for POC genetic testing.
引用
收藏
页码:1454 / 1462
页数:9
相关论文
共 50 条
[1]  
Abe T, 2011, LAB CHIP, V11, P1166, DOI [10.1039/c0lc00519c, 10.1039/c01c00519c]
[2]   A pocket-sized convective PCR thermocycler [J].
Agrawal, Nitin ;
Hassan, Yassin A. ;
Ugaz, Victor M. .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2007, 46 (23) :4316-4319
[3]   A buoyancy-driven compact thermocycler for rapid PCR [J].
Agrawal, Nitin ;
Ugaz, Victor M. .
CLINICS IN LABORATORY MEDICINE, 2007, 27 (01) :215-+
[4]   A CCD-based fluorescence imaging system for real-time loop-mediated isothermal amplification-based rapid and sensitive detection of waterborne pathogens on microchips [J].
Ahmad, Farhan ;
Seyrig, Gregoire ;
Tourlousse, Dieter M. ;
Stedtfeld, Robert D. ;
Tiedje, James M. ;
Hashsham, Syed A. .
BIOMEDICAL MICRODEVICES, 2011, 13 (05) :929-937
[5]   High Proportion of Wrongly Identified Methicillin-Resistant Staphylococcus aureus Carriers by Use of a Rapid Commercial PCR Assay Due to Presence of Staphylococcal Cassette Chromosome Element Lacking the mecA Gene [J].
Blanc, Dominique S. ;
Basset, Patrick ;
Nahimana-Tessemo, Immaculee ;
Jaton, Katia ;
Greub, Gilbert ;
Zanetti, Giorgio .
JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (02) :722-724
[6]   Mobile Phone Based Clinical Microscopy for Global Health Applications [J].
Breslauer, David N. ;
Maamari, Robi N. ;
Switz, Neil A. ;
Lam, Wilbur A. ;
Fletcher, Daniel A. .
PLOS ONE, 2009, 4 (07)
[7]   Real-time PCR detection of Listeria monocytogenes using an integrated microfluidics platform [J].
Cady, NC ;
Stelick, S ;
Kunnavakkam, MV ;
Batt, CA .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 107 (01) :332-341
[8]   Development of a toxR-based loop-mediated isothermal amplification assay for detecting Vibrio parahaemolyticus [J].
Chen, Siyi ;
Ge, Beilei .
BMC MICROBIOLOGY, 2010, 10
[9]   GeneXpert Captures Unstable Methicillin-Resistant Staphylococcus aureus Prone to Rapidly Losing the mecA Gene [J].
Ciardo, Diana E. ;
Burger, Sibylle ;
Payer, Michael ;
Lee, Christian ;
McCallum, Nadine .
JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (08) :3030-3032
[10]   Rapid detection of HIV-1 by reverse-transcription, loop-mediated isothermal amplification (RT-LAMP) [J].
Curtis, Kelly A. ;
Rudolph, Donna L. ;
Owen, S. Michele .
JOURNAL OF VIROLOGICAL METHODS, 2008, 151 (02) :264-270